ENGLISH-12
How to set additional user functions
Main menu
Sub-menu
1
SEG Used
2
1 . If you want to apply a detailed setting, press and hold the
[Timer]
and the
[Set]
button for 3 seconds or more .
- You will enter the user set mode, and the main menu will be displayed .
2 . Select a desired menu by referring to the list of a detailed setting for a wired remote controller .
- Using the [ ] / [ ] buttons, select a main menu number and press the
[Timer]
button to enter the sub-menu setting
screen .
- Using the [ ] / [ ] buttons, select a sub-menu number and press the
[Timer]
button to enter the data setting screen .
- Once you have entered the setting screen, the current setting will be displayed .
- Refer to the chart for data setting .
- Using the [ ] / [ ] buttons, change the settings and press the
[Timer]
button to move to the next setting .
- Press the
[Set]
button to save the setting and exit to the sub-menu setting screen .
- Press the
[Air Swing]
button to exit to general mode .
• While setting the data, you can change the seg number with the
[Fan Speed
/
Timer]
buttons .
• While configuring the setting, press the
[Air Swing]
button to exit to the sub-menu setting screen without
saving the setting .
NOTE
Main
Menu
Sub
Menu
Function
Default
Page
Range
Remarks
0
1
Reset to default value of a user mode
0
1
0-Disuse, 1-Reset
1
1
All locking
0
1
0-Clear, 1-Lock
2
Partial Key lock
Lock of operation ON/OFF key
0
1
0-Clear, 1-Lock
3
Lock of operation selection key
0
1
0-Clear, 1-Lock
4
Lock of temperature setting key
0
1
0-Clear, 1-Lock
5
Lock of fan speed key
0
1
0-Clear, 1-Lock
6
Lock of on or off timer setting key
0
1
0-Clear, 1-Lock
2
1
Temperature limit
Lower limit
8
1
16~30
* Nordic models
(AC
✴✴✴✴
XSC
✴
H)
: 8 ~30
2
Upper limit
30
1
OTHERS
SOL MWR-SH00N_IB_04149A-02_EN.indd 12
2016-03-02 오전 11:12:52