9. Schematic Diagrams
9-1 Schematic Diagrams
9-1
VARISTOR
L.V.TRANS
LAMP
MAIN
RELAY
POWER RELAY (SECONDARY INTERLOCK)
PRIMARY S/W
MGT CVT
TCO
FAN
MOTOR
D/MOTOR
MONITOR
SWITCH
H.V.DIODE
H. V. TRANSFORMER
H. V. CAPACITOR
120V
0V
F
FA
MAGNETRON
POWER
CORD
AC 120V/60Hz
BLK
BLK
ORG
ORG
ORG
GRN
WHT
BLU
RED
RED
RED
or
PNK
GND
FUSE
WHT
WHT
ORG
RED
WHT
YEL
COM
NC
120V
125V
25W
21V
0V
NO
FM
FLAME
TCO
DM
L
ASSY PCB BOARD
DOOR
SENSING S/W
CONDITION
DOOR IS OPENED
120V20A
PCB
PATTERN
WARNING
NOTE: CIRCUIT SHOWN WITH DOOR IS OPENED POSITION.
NOTE: FOR SERVICE REPLACEMENT USE 16 GA 105˚C
THERMOPLASTIC COVERED WIRE EXCEPT
FOR HIGH VOLTAGE LEADS OR AS NOTED ON SPECIAL LEADS.
POWER MUST BE DISCONNECTED
BEFORE SERVICING THIS APPLIANCE
BLK PNK or RED
BLK
R
RED
RED
RED
WHT
BLK
WHT WHT
WHT
ORG
ORG
WHT
BLK
MAGNETRON
HIGH VOLTAGE
DIODE
TO CHASSIS
FA
F
HIGH VOLTAGE
TRANSFORMER
POWER RELAY
DOOR SENSING SWITCH
BOTTOM
MONITOR SWITCH
CENTER
BLU
PRIMARY SWITCH
TOP
HIGH VOLTAGE CAPACITOR
BLK
RED
ORG
WHT
SYMBOL
COLOR
BLU
BLK
RED
PNK
PINK
ORANGE
WHITE
BLUE
BLACK
Samsung Electronics