4. Alignment and Troubleshooting
► Error Code
U1–2115
U1–2116
► Error message
Fuser Unit Failure #U1-2115 : Turn off then on.
Fuser Unit Failure #U1-2116 : Turn off then on.
► Symptom
The fuser unit can’t control the pressure device.
► Troubleshooting method
1) Open the rear cover. Lift up the right side and release the rear cover.
2) Check if the Actuator Cam Photo sensor is assembled correctly.
3) If there is no problem, remove 4 screws.
Copyright© 1995-2016 SAMSUNG. All rights reserved.
4-106