INSTALLATION MANUAL
MANUAL DE INSTALACIÓN
MANUEL D’INSTALLATION
MANUALE D’INSTALLZIONE
MANUAL DE INSTALAÇÃO
INSTALLATIONS-HANDBUCH

E°XEIPI¢IO E°KATA™TA™H™

àçëíêìäñàü èé ìëíÄçéÇäÖ

MULTI-SPLIT TYPE ROOM AIR CONDITIONER

( Cool and Heat )

ACONDICIONADOR DE AIRE DOMÉSTICO SISTEMA MULTI SPLIT

( Refrigeración y Calefacción )

CLIMATISEUR DE TYPE MULTIPLE

( Refroidissement et Chauffage )

CONDIZIONATORE D’ARIA PER PIÙ AMBIENTI AD UNITÀ SEPARATE

( Raffreddamento e Riscaldamento )

AR CONDICIONADO MULTI SPLIT

( Refrigeração e Aquecimento )

RAUMKLIMAGERÄT IN MEHRFACH GETEILTER AUSFÜHRUNG

( Kühlen und Wärmen )

¶O§Y¢IAIPOYMENO K§IMATI™TIKO ¢øMATIOY

(æ‡Í˘ Î·È £¤ÚÌ·ÓÛ˘ )

äéåçÄíçõâ ÇéáÑìòçõâ äéçÑàñàéçÖê íàèÄ åìãúíà-ëèãà

í (éı·ʉÂÌË ˠé·Ó„‚)

ENGLISH

ESP

A

Ñ

OL

FRAN

Ç

AIS

IT

ALIANO

POR

TUGU

Ê

S

DEUTSCH

E S F I P D G R DB98-05694A(3)

MH14VA1(A2)(C1)(C2)-07
MH18VA1(A2)(C1)(C2)-09
MH19VA1(A2)(C1)(C2)-07
MH19VA1(A2)(C1)(C2)-12

Indoor unit

MH14VA1(A2)(C1)(C2)X
MH18VA1(A2)(C1)(C2)X

MH19VA1(A2)(C1)(C2)X

Outdoor unit

E§§HNIKA

RUSSIAN

Summary of Contents for MH14VA1 Seies

Page 1: ...ATORE D ARIA PER PIÙ AMBIENTI AD UNITÀ SEPARATE Raffreddamento e Riscaldamento AR CONDICIONADO MULTI SPLIT Refrigeração e Aquecimento RAUMKLIMAGERÄT IN MEHRFACH GETEILTER AUSFÜHRUNG Kühlen und Wärmen O Y IAIPOYMENO K IMATI TIKO øMATIOY æ ÍË Î È ÚÌ ÓÛË äéåçÄíçõâ ÇéáÑìòçõâ äéçÑàñàéçÖê íàèÄ åìãúíà ëèãàí éıÎ Ê ÂÌËÂ Ë é Ó Â ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E S F I P D G R DB98 05694A...

Page 2: ...E 2 ...

Page 3: ...necting the Indoor Unit Assembly Piping 10 Cutting Extending the Piping 11 INSTALLING THE OUTDOOR UNIT Connecting the Cables to the Outdoor Unit 12 Checking Correct Earthing 14 Installing and Connecting the Outdoor Unit Drain Hose 15 Fixing the Unit in Position 15 COMPLETING THE INSTALLATION Connecting Up and Purging the Circuit 16 Refrigerant Refill 16 Performing Leak Tests 17 Placing the Indoor ...

Page 4: ...ion oil will run into the cooling circuit and seriously damage the unit Choose a location that is dry and sunny but not exposed to direct sunlight or strong winds Do not block any passageways or thoroughfares Choose a location where the noise of the air conditioner when running and the discharged air do not disturb any neighbours Choose a position that enables the piping and cables to be easily co...

Page 5: ...2 05kW or 9 000 Btu h 2 63kW B unit 9 000 2 63kW or 12 000Btu h 3 51kW Circuit breaker 20A Main power switch B D C A 1 220 240 50 Indoor unit Outdoor unit Power supply Ø V Hz MH14VA1 A2 C1 C2 MH14VA1 A2 C1 C2 X 14 000Btu h 18 000Btu h Unit Pipe size Liquid A Unit 1 4 Gas 3 8 B Unit 1 4 3 8 18 000Btu h 1 220 240 50 Indoor unit Outdoor unit Power supply Ø V Hz MH18VA1 A2 C1 C2 MH18VA1 A2 C1 C2 X 19 ...

Page 6: ...ng to install the air conditioner The 3 wire power cable and the 4 wire assembly cable are optional If these cables are not supplied use the standard cable approved by IEC standard The flare nuts are only included when the air conditioner is supplied without the assembly piping illustrated below The drain plug is supplied for heat pump model to drain the water condensed in the outdoor heat exchang...

Page 7: ... 65 mm so that it slants slightly downwards 2 If you are fixing the indoor unit to a Then follow Steps Wall 3 Window frame 4 to 6 3 Fix the installation plate to the wall in a manner appropriate to the weight of the indoor unit If you are mounting the plate on a concrete wall with anchor bolts the anchor bolts must not project by more than 20 mm 4 Determine the positions of the wooden uprights to ...

Page 8: ...assembly cable 1 Extend the assembly cable if necessary 2 Open the front grille by pulling on the tabs on the lower right and left sides of the indoor unit 3 Remove the screw securing the connector cover 4 Pass the assembly cable through the rear of the indoor unit and connect the assembly cable such as figure Each wire is labelled with the corresponding terminal number 5 Pass the other end of the...

Page 9: ...has been tested for gas leaks refer to page 17 for further details Installing and Connecting the Indoor Unit Drain Hose Care must be taken when installing the drain hose for the indoor unit to ensure that any condensation water is correctly drained outside When passing the drain hose through the 65 mm hole drilled in the wall check that none of the following situations occur The hose must NOT slop...

Page 10: ...tening the nuts first manually and then with a wrench applying the following torque Pipe Outer Diameter Torque kg cm Liquid refrigerant 6 35 mm 160 Gas refrigerant 9 52 mm 300 Gas refrigerant 12 70 mm 500 If the piping must be shortened or extended refer to page 11 4 Cut off any excess foam insulation 5 If necessary bend the pipe round along the bottom of the indoor unit and out through the approp...

Page 11: ...correctly Oblique Rough Burr 3 To prevent any gas from leaking out remove all burrs at the cut end of the pipe using a reamer 4 Slide a flare nut on to the pipe and modify the flare Pipe Outer Diameter D Depth A Liquid refrigerant 6 35 mm 1 3 mm Gas refrigerant 9 52 mm 1 8 mm Gas refrigerant 12 70 mm 2 0 mm 5 Check that the flaring is correct referring to the illustrations below for examples of in...

Page 12: ...mbly cable with the power cable such as figure Each wire is labelled with the corresponding terminal number Ensure the wire number of the indoor unit and the terminal number of the outdoor unit 3 Connect the earth wires to the earth terminals Refer to the page 14 for further details on how to check that earthing is correct 4 Replace the terminal board cover carefully tightening the screw 5 Connect...

Page 13: ...N1 1 2 E N L E L N 2 1 N1 2 1 N1 N1 E E E 1 2 N1 1 2 N1 1 2 N1 1 2 Indoor unit Outdoor unit Earth terminal A unit B unit Earth terminal Earth terminal Earth terminal Earth terminal Terminal block Assembly cable Circuit Breaker Main Power supply cable ...

Page 14: ...hole of the size indicated in the illustration opposite drive the earthing electrode into position and cover the top of the electrode with the excavated soil 4 Install a green yellow insulated earthing wire Ø1 6 mm section 2 mm2 or greater If the earthing wire is too short connect an extension lead soldering the connection and wrapping it with insulating tape do not bury the soldered connection Se...

Page 15: ...e Fixing the Unit in Position The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration particularly if the outdoor unit is to be installed close to a neighbour If it is to be installed in a location exposed to strong winds or at a height the unit must be fixed to an appropriate support wall or ground 1 Position the outdoor unit so that th...

Page 16: ...itional refrigerant up to total 30 metres of connecting pipe 1 Remove the valve stem cap and service port of 3 way valve 2 Connect the charging hose of low pressure side of manifold gauge to the packed valve having a charging port 3 8 or 1 2 Packed valve 3 Operate the unit at the cooling mode 4 Slowly open the valve of the low pressure side of manifold gauge counterclockwise until the low pressure...

Page 17: ...ation plate 1 To avoid condensation problems place heat resistant polyethylene foam separately around each refrigerant pipe in the lower part of the indoor unit 2 Wind insulating tape around the pipes assembly cable and drain hose 3 Place the resulting bundle carefully in the lower part of the indoor unit making sure that it does not jut out from the rear of the indoor unit 4 Hook the indoor unit ...

Page 18: ...e connection Step 2 Check the room select switch in the indoor unit Move the room select switch downward in the A unit and move the switch upward in the B unit Set an indoor unit connected to upper service valves to the A unit then set the other indoor unit connected to lower service valves to the B unit The liquid and gas refrigerant pipes should not be crossed with each other Step 3 Apply the po...

Page 19: ...ou have set the switch to the proper position Quantity of refrigerant The error can be occurred when the refrigerant is insufficient Connection of refrigerant pipes Upper service valves on the outdoor unit are for the A unit and the others lower service valves are for the B unit Refrigerant pipe should not be crossed with each other ...

Page 20: ...opriate pages in the owner s instruction booklet 1 How to start and stop the air conditioner 2 How to select the operating mode and adjust the temperature and fan settings 3 How to adjust the air flow direction 4 How to set the timers 5 How to remove and clean the filters Once the owner is happy with the basic operations hand over the owner s instruction booklet and this installation manual for st...

Page 21: ...ATIONS Technical Specifications Model Indoor unit MH14VA1 A2 C1 C2 07 MH18VA1 A2 C1 C2 09 MH19VA1 A2 C1 C2 07 MH19VA1 A2 C1 C2 12 220 240V 50Hz Model Outdoor unit Power Supply MH14VA1 A2 C1 C2 X MH18VA1 A2 C1 C2 X MH19VA1 A2 C1 C2 X ...

Page 22: ...NADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR QUESTO CONDIZIONATORE D ARIA È PRODOTTO DA ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR DIESE KLIMAANLAGE IST FABRIZIERT VON AYTH H Y KEYH KATA KEYA THKE A O ùíéí äéçÑàñàéçÖê àáÉéíéÇãÖç îàêåéâ Printed in Korea ...

Reviews: