Deciding on Where to Install the Air Conditioner
PREPARING THE INSTALLATION
MH050FX
A2
Indoor unit
Outdoor unit
Power supply
Ø, V, Hz
026/035
MH050FX
A2
1,208-230, 60
Unit
Outside diameter
Liquid
Gas
026/035
1/4"
3/8"
MH052FX
A2
outdoor unit cannot be connected to the following indoor unit combination.
-MH052FNCA/MH052FECA
Piping outside diameter
(h)
(H)
A
B
23.6 inch
minimum
1 Room max
length
2 Room total max
length
Max height between
indoor unit & outdoor unit
Max height between
indoor units
Dimension
65.6ft
98.4ft
49.2ft
24.6ft
Composition
A,B
A+B
(H)
(h)
Piping length and the height
Main power switch
7.86 inch
or more
6.29 inch
or more
3.93 inch
or more
11.8 inch
minimum
11.8 inch
minimum
23.6 inch-
minimum
CAUTION:
9.84ft as minimum pipe length: It will
reduce noise and vibration.
This value must be increased at 24.6 ft in
case it is connected just one indoor unit.
System can work with one indoor unit connected, but it is recommended that the TOTAL number
of indoor unit suggested by manufacturer are connected to obtain the maximum performance.
The appearance of the unit may be different from the diagram depending on the model.
Make at least one round:
It will reduce noise and vibration