E-
8
PREPARING THE INSTALLATION
Deciding on Where to Install the Air Conditioner (Continued)
MH070FXEA4A / MH080FXEA4A
The split type, 1-way cassette, mini 4-way cassette and slim duct type indoor units can be installed together.
Indoor unit
Outdoor unit
Power supply
Ø, V, Hz
020/023/026/030/035/052
MH070FXEA4A
MH080FXEA4A
1,220-240, 50
Unit
Outside diameter
Liquid
Gas
020/023/026/030/035
1/4"
3/8"
052
1/4"
1/2"
Piping outside diameter
(h)
(H)
A
B
1 Room max
length
4 Room total max
length
Max height between
indoor unit & outdoor unit
Max height between
indoor units
Dimension
25m
70 m
15m
7.5 m
Composition
A,B,C,D
A+B+C+D
(H)
(h)
Piping length and the height
C
D
200 mm
or more
160 mm
or more
100 mm
or more
Main power switch
600 mm
minimum
300 mm
minimum
300 mm
minimum
600 mm
minimum
26926A_IM_E.indd 8