- 8 -
4-6-2 Removal of Door “E”
1. Following the procedure as shown in the fi gure,
insert and bend a thin metal plate between Door “E”
and Door “A” until you hear the ‘tick’ sound.
2. Insertion depth of the thin metal plate should be
0.5mm or less.
4-6-3 Removal of Screen Door and Door A
1. Disassemble hook from Screen Door to Door-A.
4-6-4 Removal of Key Door & Spring
1. Push up key door, take out key door from Door “E”
Door “E” slot.
2. Take out spring.
Key Door
Spring
Door "E"
Door “E”
Door “A”
4-6-5 Reassembly Test
1. When mounting the door to the oven, be sure to adjust the door parallel to the bottom line of the oven face
plate by moving the upper hinge and lower hinge in the direction necessary for proper alignment.
2. Adjust so that the door has no play between the inner door surface and oven front surface. If the door assem-
bly is not mounted properly, microwave energy may leak from the space between the door and oven.
3. Do the microwave leakage test.
After replacement of the defective component parts of the door, reassemble it and follow the instructions
below for proper installation and adjustment so as to prevent an excessive microwave leakage.