 Safety Precautions

  

Read carefully this installation manual before installation and check 

whether the OnOff controller is installed correctly after installation.

  

Do not attempt to install or repair this OnOff controller by yourself.

  

This OnOff controller contains no user-serviceable parts. Always 

consult authorized service personnel for repairs.

  

When moving, consult authorized service personnel for 

disconnection and installation of the OnOff controller.

  

Ensure that the wall is strong enough to support the weight of the 

OnOff controller.

  

The OnOff controller must be installed according to the national 

electrical rules by an installation specialist.

  

When wiring, connect the supplied wires firmly and fasten them 

securely so that external force cannot be applied to the terminal 

connection area.

  

Position all the wires correctly so that the cover of the electric 

equipment section doesn’t float. Then securely fasten the cover.

  

Before handling or adjusting the power loading terminal, switch 

off the power supply.

  

When you want to disuse the OnOff controller, consult authorized 

installation center.

 

WARNING

 

CAUTION

  

Do not use inflammable gases near the OnOff controller.

  

  Do not install the OnOff controller in a location where it will come 

into contact with the combustible gases, machine oil, sulphide gas, 

etc.

  

 Avoid a location where acid/alkali solution or special spray is used.

  

 Choose a location that is dry and sunny, but not exposed to direct 

sunlight. Available temperature is between 0°C(32°F) and 39°C(102°F).

  

Do not spill water into the OnOff controller.

  

Do not give tensile strength to the cable to avoid disconnection.

  

Do not press buttons with a pointed thing.

  

Do not connect the power cable to the control terminal.

  

If the OnOff controller is installed in a hospital or other special 

places, it should not affect other electronic devices.

  

Do not install the product in an area where mineral oil is kept or 

arsenic acid of oil and steam frequently exist such as a kitchen. 

  

Do not install the product in an area where corrosive gases such as 

ammonia gas or sulfurous acid gas are generated e.g. an exhaust 

pipe of a toilet or an outlet of ventilating opening.

  

Do not install the product in an area where a machine that 

generates electromagnetic waves is placed.

  

Do not install the product in an area where combustible gas 

leakage is expected or volatile flammable material such as thinner 

and gasoline are handled. 

  

Do not install the product in an area where carbon textile or 

flammable dust float in the air.

  

Do not install the product in an area where corrosion is expected 

such as shoreline and hot spring.

This installation manual indicates you to install the OnOff controller which is connected to 

the indoor unit. For installation of other optional accessories, see an appropriate installation 

manual.

2

OnOff Controller MCM-A200DN_IM_EN_03721A(1).indd   2

2013-02-06   오후 6:40:07

Summary of Contents for MCM-A202DN

Page 1: ...OnOff Controller MCM A200DN_IM_EN_03721A 1 indd 12 2013 02 06 오후 6 40 09 ...

Page 2: ... Conditioner installation manual imagine the possibilities ThankyouforpurchasingthisSamsungproduct This manual is made with 100 recycled paper EN DB68 03721A 1 OnOff Controller MCM A200DN_IM_EN_03721A 1 indd 13 2013 02 06 오후 6 40 09 ...

Page 3: ...kali solution or special spray is used Choose a location that is dry and sunny but not exposed to direct sunlight Available temperature is between 0 C 32 F and 39 C 102 F Do not spill water into the OnOff controller Do not give tensile strength to the cable to avoid disconnection Do not press buttons with a pointed thing Do not connect the power cable to the control terminal If the OnOff controlle...

Page 4: ...or unit Indoor unit Indoor unit Indoor unit RMC 00 RMC 04 RMC OA RMC OB RMC OC RMC OD RMC OE RMC OF RMC 05 RMC 06 RMC 07 RMC 08 RMC 09 RMC 01 RMC 02 RMC 03 Wirerangethatcan beconnectable Rated Dimension Stud Dimension Basic dimension mm inch AWG mm2 inch2 mm2 inch2 mm inch t Φd1 E F W L 22 16 0 25 1 65 0 0003 0 0025 1 5 0 0023 3 0 1181 0 7 0 0275 3 8 0 1496 4 5 0 1771 6 3 0 2480 5 5 0 2165 19 05 0...

Page 5: ...address of Indoor Unit Example RMC 1 SEG11 0 F RMC 2 SEG12 0 F However when RMC 1 F RMC 2 can be set between 0 E In Case of Installing OnOff Controller Only OnOff Controller You must reset the OnOff controller to apply the changed RMC 1 address SW22 SW21 SW22 SW21 DIP Switch RMC 1 address SW01 0 F Cooling Heating switch Cooling Heating OFF Left ON Right OnOff Controller MCM A200DN_IM_EN_03721A 1 i...

Page 6: ...controller 1 use the OnOff controller When setting the installation option X SEG11 SEG12 RMC 1 RMC 2 address 00 FE SEG9 When setting the address option 1 RMC address setting X X X Note Detailed method about Installation option establishment refers to Indoor Unit manual Installation option must set the SEG2 value as 2 in Indoor Unit option code Address option must set the SEG2 value as A in Indoor ...

Page 7: ...ng 1 2 LEVEL 0 OFF OFF Among the various controllers such as the OnOff controller wired wireless controller and the indoor unit button the air conditioner will only be able to operate with the most recently used controller LEVEL 1 ON OFF The wired wireless controller can only be used when the OnOff controller is powered on LEVEL 2 OFF ON The air conditioner can only be operated with the OnOff cont...

Page 8: ...option SW21 Contents 1 2 ON Disable OnOff controller usage OFF Enable OnOff controller usage All the DIP switches of the OnOff controller is set to OFF as factory default setting SW21 setting of the DIP switch will be applied instantly Option setting for communication can be executed regardless of the Level setting OnOff Controller MCM A200DN_IM_EN_03721A 1 indd 7 2013 02 06 오후 6 40 08 ...

Page 9: ...ddress set to 0 RMC 1 address set to 1 RMC 1 address set to 2 Indoor Unit 1 15 assign Indoor Unit 16 31 assign Indoor Unit 32 64 assign To install 128 units to 16 or less number of outdoor units Group control of units Control layer connection OnOff Controller MCM A200DN_IM_EN_03721A 1 indd 8 2013 02 06 오후 6 40 08 ...

Page 10: ...6 7 8 9 A B C D E F Indoor unit 31 Indoor unit 30 Indoor unit 29 Indoor unit 18 Indoor unit 17 Indoor unit 16 Indoor unit 32 Indoor unit 33 Indoor unit 34 Indoor unit 45 Indoor unit 46 Indoor unit 47 Indoor unit 63 Indoor unit 62 Indoor unit 61 Indoor unit 50 Indoor unit 49 Indoor unit 48 Indoor unit 0 Indoor unit 1 Indoor unit 2 Indoor unit 13 Indoor unit 14 Indoor unit 15 OnOff Controller MCM A2...

Page 11: ...ller RMC 1 address set to 0 RMC 1 address set to 1 RMC 1 address set to 2 Indoor Unit 1 15 assign Indoor Unit 16 31 assign Indoor Unit 32 64 assign To install 80 units for 1 outdoor unit Group control of units Set layer connection OnOff Controller MCM A200DN_IM_EN_03721A 1 indd 10 2013 02 06 오후 6 40 09 ...

Page 12: ...6 7 8 9 A B C D E F Indoor unit 31 Indoor unit 30 Indoor unit 29 Indoor unit 18 Indoor unit 17 Indoor unit 16 Indoor unit 32 Indoor unit 33 Indoor unit 34 Indoor unit 45 Indoor unit 46 Indoor unit 47 Indoor unit 63 Indoor unit 62 Indoor unit 61 Indoor unit 50 Indoor unit 49 Indoor unit 48 Indoor unit 0 Indoor unit 1 Indoor unit 2 Indoor unit 13 Indoor unit 14 Indoor unit 15 OnOff Controller MCM A2...

Reviews: