BASIC TECHNICAL INFORMATION FOR:
SAMSUNG MAX
MINI-SPLIT UNITS
Page 1: ...WWW SUNLIGHTSUPPLY COM Distributed by BASIC TECHNICAL INFORMATION FOR SAMSUNG MAX MINI SPLIT UNITS...
Page 2: ...0 16 oz ft over 25 ft CHARGE FOR LINE RUN LENGTHS Length 25 35 45 50 Added Charge oz 0 1 6 3 3 4 0 INTERCONNECTING WIRING Gauge 14 AWG Power 16 AWG Shielded Communication Number of Interconnecting Wir...
Page 3: ...OR LINE RUN LENGTHS Length 25 35 45 55 65 75 85 95 98 Added Charge oz 0 1 6 3 2 4 8 6 4 8 0 9 6 11 2 11 68 INTERCONNECTING WIRING Gauge 14 AWG Power 16 AWG Shielded Communication Number of Interconnec...
Page 4: ...LINE RUN LENGTHS Length 25 35 45 55 65 75 85 95 98 Added Charge oz 0 4 3 8 6 12 9 17 2 21 5 25 8 30 1 32 25 INTERCONNECTING WIRING Gauge 14 AWG Power 16 AWG Shielded Communication Number of Interconne...
Page 5: ...quired to control MAX models with Samsung central control options upper level control Includes sub PCB 4 crimp wire connectors wire harness and sub PCB cover sub PCB Wire Harness sub PCB 1 With the po...
Page 6: ...ntly pull this wire upward and out of the unit 3 Connect the PCB to the PCB wire harness a and to the sub PCB wire harness b NOTE the sub PCB wire harness is included with the wired controller a b 4 R...
Page 7: ...red controller wires already installed pull the wires through the front of the indoor unit Cut the 2 small plastic connectors off the ends of the sub PCB wire harness the ends of the red blue and yell...
Page 8: ...CAN BE EXPECTED DOWN TO 0 F OUTDOOR TEMPERATURE PLEASE NOTE THAT IF A PROLONGED OFF CYCLE IS EXPERIENCED IN OUTDOOR TEMPERATURES BELOW 10 F THE UNIT MAY NOT RESTART UNTIL THE TEMPERATURE RISES ABOVE...
Page 9: ...an adverse affect on the system s ability to properly return oil to the compressor Over time this will cause inconsistent performance error codes and premature failure of components Ceiling Cassette...