4-2
4. Troubleshooting
4-1-1. No Power
Symptom
The LEDs on the front panel do not work when connecting the power cord.
The SMPS relay does not work when connecting the power cord.
The units appears to be dead.
-
-
-
Major
checkpoints
The IP relay or the LEDs on the front panel does not work when connecting the power cord if the cables are
improperly connected or the Main Board or SMPS is not functioning. In this case, check the following:
Check the internal cable connection status inside the unit.
Check the fuses of each part.
Check the output voltage of SMPS.
Replace the Main Board.
-
-
-
-
Diagnostics
Does proper DC A3.3V
appear at C1031?
Check a IC1003
Change a main PCB ass’y
No
Yes
Does proper DC 1.8V, 1.25V appear at
R1081, C1045?
No
Yes
LAMP off, power indicator
LED red color?
Yes
No
Check a connection a power cable.
Does proper DC5V appear at
pin 9 of CN1001?
No
Yes
A power is supplied to set?
Change a Assy PCB Power.
Check a IC1008, IC1004
Change a main PCB ass’y
1
2
3
4
Caution
Make sure to disconnect the power before working on the IP board.
Summary of Contents for LN26B350F1
Page 6: ...1 4 1 Precautions Memo ...
Page 19: ...4 4 4 Troubleshooting WAVEFORMS 1 R G B Output Signal ...
Page 21: ...4 6 4 Troubleshooting WAVEFORMS 2 Digital Output Data 3 Signal of HDMI Data ...
Page 23: ...4 8 4 Troubleshooting WAVEFORMS 3 CVBS Output Signal 4 Tuner_CVBS Output Signal ...
Page 25: ...4 10 4 Troubleshooting WAVEFORMS 4 CVBS Output Signal ...