4-2
4. Troubleshooting
4-1-1. No Power
Symptom
The LEDs on the front panel do not work when connecting the power cord.
-
The SMPS relay does not work when connecting the power cord.
-
The units appears to be dead.
-
Major
checkpoints
The IP relay or the LEDs on the front panel does not work when connecting the power cord if the cables are
improperly connected or the Main Board or SMPS is not functioning. In this case, check the following:
Check the internal cable connection status inside the unit.
-
Check the fuses of each part.
-
Check the output voltage of SMPS.
-
Replace the Main Board.
-
Diagnostics
2
3
3
1
Does proper DC A3.3V
appear at BD215?
Check a IC201.
Change a main PCB ass’y.
No
Yes
Does proper DC 3.3V, 1.1V
appear at BD216, BD233?
No
Yes
LAMP off, power indicator
LED red color?
Yes
No
Check a connection a power cable.
Does proper DC5V appear at
pin 4 of CN210_18P?
No
Yes
A power is supplied to set?
Change a Assy PCB Power.
Check a IC203, IC204.
Change a main PCB ass’y.
1
2
3
Caution
Make sure to disconnect the power before working on the IP board.
Summary of Contents for LA32C550J1R
Page 24: ...4 4 4 Troubleshooting WAVEFORMS PC input V sink H sink R G B LVDS output...
Page 26: ...4 6 4 Troubleshooting WAVEFORMS HDMI input RX_Data RX_Clk LVDS output...
Page 28: ...4 8 4 Troubleshooting WAVEFORMS CVBS OUT Grey Bar LVDS output...
Page 30: ...4 10 4 Troubleshooting WAVEFORMS LVDS output...
Page 32: ...4 12 4 Troubleshooting WAVEFORMS I2S Data Speaker out...
Page 75: ...6 1 6 Wiring Diagram 6 Wiring Diagram 6 1 Wiring Diagram LA32 37C550...
Page 76: ...6 2 6 Wiring Diagram LA40 46C550...