background image

                                                                               

 

 
 

7) Select MAC address at 

“Board list”

 

8) Enter IP Address, Subnet mask, Default Gateway according to your Sub environment. 

- Caution:

 There is no Gateway when the printer is connected to PC direct. Write the   

Same with IP address at Gateway address.   

- Notice:

 Ethernet interface requests Gateway device to save its own IP address when   

Data transmission does not take place for more than 5 minutes 

 
9) Enter value at Local port. 

(Default: 

6000, 

choose from 6000 to 10000) 

 

10) Set Baud rate. 

(Set it as same as the printer condition. Highest bps can be used) 

 
11) When setting finishes select 

“Setting”

 

12) Select 

“Exit”

 and finish the program. 

 
 

NOTE 1.   

“DHCP mode” is for

 DHCP server. 

      (DHCP: Dynamic Host Configuration Protocol) 

 

NOTE 2.    “Upload” button is used to upgrade Firmware. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

V3.0.0                                                     

www.samsungminiprinters.com

 

5

Summary of Contents for IFA-E

Page 1: ...Ethernet user manual Model name Front picture Rear picture IFA E SRP 350 SRP 350II SRP 270 IFB E SRP 370 SRP 372 V3 0 0 www samsungminiprinters com 1 ...

Page 2: ...se the designated tool file described below for the optimal operation according to each interface version This version is described on the metal bracket Each tool file can be downloaded from website www samsungminiprinters com Interface Version Model name Applicable printers Tool file Network interface IFA E SRP 350 270 350II V 3 x x IFB E SRP 370 372 Ethernet_V3 x zip 10 100 Base T All in one V 2...

Page 3: ...rnet interface card 3 Set a serial communication speed at the highest bps SRP 350 57 600bps SRP 370 372 350II 115 200 bps SRP 270 19 200 bps 4 Connect LAN cable to Ethernet interface card and turn on the printer Use Direct cable 1 1 cable to connect to HUB Switch Use Cross cable to connect to LAN card of computer 5 Run Configure_V3 xx exe V3 0 0 www samsungminiprinters com 3 ...

Page 4: ...6 Select Search If you know IP address check in the box of Direct configuration and enter IP address Then select search V3 0 0 www samsungminiprinters com 4 ...

Page 5: ...ce to save its own IP address when Data transmission does not take place for more than 5 minutes 9 Enter value at Local port Default 6000 choose from 6000 to 10000 10 Set Baud rate Set it as same as the printer condition Highest bps can be used 11 When setting finishes select Setting 12 Select Exit and finish the program NOTE 1 DHCP mode is for DHCP server DHCP Dynamic Host Configuration Protocol ...

Page 6: ...ms are Win 2000 XP 2003 server Follow the Installation procedure below if required 1 Install printer driver 1 1 Download and install the printer driver from homepage www samsungminiprinters com 1 2 Re boot the personal computer 2 Open printer properties box at installed printer driver V3 0 0 www samsungminiprinters com 6 ...

Page 7: ...3 Select Ports and click the button Add Port 4 Select Standard TCP IP port and choose New Port V3 0 0 www samsungminiprinters com 7 ...

Page 8: ...dard TCP IP Printer Port Wizard activated 6 Write IP address at box Printer Name or IP Address and go next IP address in this case must be the same as the value given to Ethernet card V3 0 0 www samsungminiprinters com 8 ...

Page 9: ...7 Go next 8 Select Close V3 0 0 www samsungminiprinters com 9 ...

Page 10: ...9 Click the button Configure Port 10 Enter Port Number and OK It must be same as the value given to Ethernet card V3 0 0 www samsungminiprinters com 10 ...

Page 11: ...11 Go Apply 12 Select General Print Test Page and check whether print is okay V3 0 0 www samsungminiprinters com 11 ...

Page 12: ...400 on on 19200 off off 9600 on off DTR DSR SW1 3 off 8 data bit SW1 4 off none parity SW1 5 off SRP 270 bps SW2 7 SW2 8 19200 On On 9600 Off Off 4800 On Off 2400 Off On DTR DSR SW2 3 off 8 data bit SW1 4 off none parity SW1 5 off SRP 370 SRP 372 bps SW1 1 SW1 2 115200 on on 38400 off on 19200 on off 9600 off off DTR DSR SW1 3 off 8 data bit MSW9 none parity MSW9 ...