Power over Ethernet Commands
4-213
4
Power over Ethernet Commands
The commands in this group control the power that can be delivered to attached
PoE devices through switch ports on the iES4028FP and iES4024GP.
The switch’s power management enables total switch power and individual port
power to be controlled within a configured power budget. Port power can be
automatically turned on and off for connected devices, and a per-port power priority
can be set so that the switch never exceeds its allocated power budget. When a
device is connected to a switch port, its power requirements are detected by the
switch before power is supplied. If the power required by a device exceeds the
power budget of the port or the whole switch, power is not supplied.
Console#show lacp sysid
Port Channel System Priority System MAC Address
-------------------------------------------------------------------------
1 32768 00-13-F7-D3-7E-60
2 32768 00-13-F7-D3-7E-60
3 32768 00-13-F7-D3-7E-60
4 32768 00-13-F7-D3-7E-60
5 32768 00-13-F7-D3-7E-60
6 32768 00-13-F7-D3-7E-60
7 32768 00-13-F7-D3-7E-60
8 32768 00-13-F7-D3-7E-60
Console#
Table 4-57 show lacp sysid - display description
Field
Description
Channel group
A link aggregation group configured on this switch.
System Priority
*
LACP system priority for this channel group.
System MAC Address
System MAC address.
* The LACP system priority and system MAC address are concatenated to form the LAG system ID.
Table 4-58 PoE Commands
Command Group
Function
Mode Page
power mainpower
maximum allocation
Sets the maximum power available to all switch ports
GC
power inline compatible
Provides power to pre-standard PoE devices
GC
power inline
Turns power on and off for specific ports
IC
power inline
maximum allocation
Sets the maximum power available to specific switch ports
IC
power inline priority
Sets the priority for power supplied to specific ports
IC
show power inline status Displays the current status of power management on specific
ports or all ports
PE
show power mainpower
Displays the current status of power management for switch
PE
Summary of Contents for iES4024GP
Page 1: ...iES4028F 4028FP 4024GP ...
Page 4: ...iv This page is intentionally left blank ...
Page 10: ...x This page is intentionally left blank ...
Page 28: ...Contents xxviii This page is intentionally left blank ...
Page 32: ...Tables xxxii This page is intentionally left blank ...
Page 46: ...Introduction 1 10 1 This page is intentionally left blank ...
Page 336: ...Configuring the Switch 3 280 3 This page is intentionally left blank ...
Page 688: ...Command Line Interface 4 352 4 This page is intentionally left blank ...
Page 702: ...Glossary Glossary 8 This page is intentionally left blank ...
Page 710: ...Index 8 Index This page is intentionally left blank ...
Page 711: ...This page is intentionally left blank ...
Page 712: ...iES4028F 4028FP 4024GP ...