iDCS 500
PROGRAMMING
TECHNICAL MANUAL
PART 2 APRIL 2002
MMC: 856
TECH PROGRAMMING LOGS
DESCRIPTION:
This MMC lists the date, time and entry location of the last 8 times that technician
programming was accessed. This will allow a technician to determine if there was
unauthorised access to system programming and where this access occurred. The
information stored in this log will consist of 2 elements, the date and time it occurred
at and the access location.
✳
Tech. Programming Logs is only available on a system with a LAN module
installed on the MCP card.
There are 4 types of access location information as described below:
NNNN
This would be the extension number of a keyset that had accessed
programming directly.
MODEM This would indicate that programming was accessed by PCMMC via the
integrated V90 modem attached to the Left side of the main cabinet.
LAN
This would indicate that programming was accessed by PCMMC via the
LAN connection on the left side of the main cabinet.
SIO X
This would indicate that programming was accessed by PCMMC via one
of the SIO connections on the left side of the main cabinet where X is the
number (1~4) of the SIO port that was used.
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor left and right
SPK
Used to store data and advance to next MMC
HOLD
Used to clear previous entry
ACTION
DISPLAY
1. Press TRSF 856
Display shows
(1) 10/30 01:24
207:10/30 01:25
HELP
Table of
Contents
HOME
PAGE