background image

Solving Common Problems

Explanation/Solution

Check that the breaker used for the air conditioner is switched on.

Check that the operation indicator on the indoor unit is on;  

if necessary press the       (On/Off) button on the remote control.

Check whether the Timer indicator on the indoor unit is switched on. 

If so:
- Wait until the switch-on time is reached and the air conditioner starts  

up automatically

- Cancel the timer (see pages 16 and 17 for further details)

Check that there are no obstacles between you and the indoor unit.

Check the remote control batteries.

Check that you are close enough to the indoor unit (seven meters/

yards or less).

Check that you are pointing the remote control at the remote control 

sensor in the right of the indoor unit.

Replace the remote control batteries if necessary.

Check that the correct operating mode has been selected (AUTO, 
COOL).

The room temperature may be too low.

Dust may be blocking the air filter guard; refer to page 22 for cleaning 

instructions.

Check that there is no obstacle in front of the outdoor unit.

Check that the operating mode is set to COOL or FAN ; in the 

AUTO mode, the fan speed changes automatically and in the

DRY mode, it is set to AUTO.

Check that the air conditioner has been switched on; if necessary, 

press the       (On/Off) button on the remote control.

Check that the timer has been programmed correctly; see pages 16 

and 17.

Air the room.

Problem

The air conditioner does not
operate at all

The air conditioner does not
operate with the remote control

No beep is heard when you press
the      (On/Off) on the remote 
control

The air conditioner does not cool

The fan speed does not change
when you press the           button

The air flow direction does not 
change when you press the

button

The timer is not correctly triggered 

Odour is permeated in the room
during air conditioning

Before contacting the after-sales service, perform the following simple checks.
They may save you the time and expense of an unnecessary call.

E-

21

ENGLISH

Summary of Contents for IAST18SJGE/XSG

Page 1: ...ico sistema Split Refrigeraci n Climatiseur de type S par Refroidissement AST18SJGB S AST18SJGE S AST24S6GBD S AST24S6GED S Indoor unit UST18SJGB S UST18SJGE S UST24S6GBD S UST24S6GED S Outdoor unit O...

Page 2: ...e Use the remote control within 7 meters from the indoor unit If applicable WARNING DURING OPERATION Never store or load the air conditioner upside down or sideways to prevent the damage of the compre...

Page 3: ...ity 12 Airing Your Room 13 Selecting Energy Saving Mode 14 Adjusting the Air Flow Direction Vertically 15 Adjusting the Air Flow Direction Horizontally 15 PROGRAMMING YOUR AIR CONDITIONER Setting the...

Page 4: ...gn and shape are subject to change according to the model Indoor Unit Air filter under the grille Air flow blades outlet Air Inlet On Off switch Remote senser Turbo indicator GREEN Operation indicator...

Page 5: ...E 5 ENGLISH Air Inlet Rear Air Outlet Connection Valve Outdoor Unit UST18SJGB S UST18SJGE S Air Inlet Rear Air Outlet Connection Valve Outdoor Unit UST24S6GBD S UST24S6GED S...

Page 6: ...N Turbo Sleep mode selection button Swing button On Timer button Off Timer button On Off Timer Set Cancel button Fan speed adjustment button Temperature adjustment buttons Temperature setting Sleep mo...

Page 7: ...ake full advantage of the unit s features The booklet is organized as follows The following figures are shown on pages from 4 to 6 Indoor and outdoor units Remote control buttons and display They will...

Page 8: ...battery with on the remote control 1 2 Close the cover by sliding it back until it clicks into place 3 Use two AAA LR03 1 5V batteries Do not use old batteries or different kinds of batteries togethe...

Page 9: ...change modes at any time If necessary press the On Off button Result The air conditioner starts up in Cool mode with Turbo fan speed The operation indicator on the indoor unit lights up The indoor uni...

Page 10: ...d Possible temperatures are between 18 C and 30 C inclusive Result Each time you press the button The temperature is adjusted by 1 C The indoor unit beeps The air conditioner starts cooling provided t...

Page 11: ...urbo fan speed The operation indicator on the indoor unit lights up The indoor unit beeps 2 Press the button Result The temperature and fan settings are adjusted automatically The air conditioner cool...

Page 12: ...three minutes 2 If the is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press the...

Page 13: ...p of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press the button The air conditioner runs in FAN mode The t...

Page 14: ...nder 26 C cancel the Energy saving mode before adjusting the temperature 6 To control the direction of the air flow refer to page 15 5 To select the fan speed press the button one or more times until...

Page 15: ...Cooling Upwards 2 If you want the blade to move up and down automatically when the air conditioner is operating press the button Result The blade move up and down around the base position set 3 To st...

Page 16: ...ton to complete the setting Result The remaining time is displayed Blinking of the timer indicator stops The selected mode and the temperature on the display disappear after 10 seconds The air conditi...

Page 17: ...inking of the timer indicator stops The air conditioner will switch off automatically when the counter displayed on the remote control reaches the set time and disappears the Off timer setting 2 If yo...

Page 18: ...s until appears on the remote control Result The indoor unit beeps The air conditioner will be controlled as indicated in the illustrations below Cooling The desired temperature is increased by 1 C ev...

Page 19: ...ioner can be used If the air conditioner is used at Then High temperatures The automatic protection feature may be triggered and the air conditioner stopped Mode Outdoor Temperature Indoor Temperature...

Page 20: ...on press the On Off switch on the right side of the indoor unit Result The Operation indicator on the indoor unit comes on The indoor unit beeps The air conditioner starts up in the most suitable mode...

Page 21: ...ay be too low Dust may be blocking the air filter guard refer to page 22 for cleaning instructions Check that there is no obstacle in front of the outdoor unit Check that the operating mode is set to...

Page 22: ...Before cleaning your air conditioner ensure that you have switched off the breaker used for the unit 1 Open the upper front grille by pulling right and left sides of the grille 2 Slide the lower front...

Page 23: ...Technical Specifications E 23 ENGLISH Model Indoor unit 220V 60Hz AST18SJGE S AST24S6GED S AST18SJGB S AST24S6GBD S 220 240V 50Hz Power Supply...

Page 24: ...ELECTRONICS THIS AIR CONDITIONER IS MANUFACTURED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR...

Reviews: