25
Burner Features
Nominal heat input and flow rates see below at 15˚C at 1,013 mbar.
(Table 1)
COUN-
TRY
TYPE OF
GAS
BURNER
Rapid
Semi-rapid
Auxiliary
Total
POSITION
Max
Min
Max
Min
Max
Min
GB,IT
FR,HU
BE,LT
NL,PT
G-30
BUTANE
29 mbar
Injector make
(1/100 mm)
85
65
50
-
Nominal heat input
(Kw)
3.0
0.75
1,75
0.43
1.0
0.37
7.5
Nominal flow rates
(g/h)
211.1 53.4 119.5 30.5
71.2
25.4
PL
G-30
BUTANE
36 mbar
Injector make
(1/100 mm)
80
62
47
-
Nominal heat input
(Kw)
3.0
0.85
1,75
0.48
1.0
0.38
7.5
Nominal flow rates
(g/h)
203.4 58.5 124.6 33.1
71.2
25.4
GB,IT
FR,BE
LT,PT
G-31
PROPANE
37 mbar
Injector make
(1/100 mm)
85
65
50
-
Nominal heat input
(Kw)
3.0
0.7
1,75
0.4
1.0
0.33
7.5
Nominal flow rates
(g/h)
199.4 49.4 117.7 28.5
68.4
22.8
GB,IT
FR,BE
LT,PT
PL
G-20
NATURAL
20 mbar
Injector make
(1/100 mm)
115
97
72
-
Nominal heat rating
(Kw)
3.0
0.78
1,75
0.51
1.0
0.29
7.5
Nominal flow rating
(ℓ/h)
271
74
168
48
97
28
HU
G-20
NATURAL
25 mbar
Injector make
(1/100 mm)
110
91
68
-
Nominal heat input
(Kw)
3.0
0.84
1,75
0.57
1.0
0.32
7.5
Nominal flow rates
(ℓ/h)
271
79
166
54
91
30
Burner
Calibrated orifice 1/100mm
Auxiliary
31
Semi-rapid
34
Rapid
45
- Aeration adjustment none
26
MEMO