Remove the magnetron including the shield case,
permanent magnet, choke coils andF capacitors (all
of which are contained in one assembly).
1. Disconnect all lead wires from the magnetron
and lamp.
2. Remove a screw securing the magnetron
supporter.
3. Remove the magnetron supporter.
4. Remove the air cover.
5. Remove screws securing the magnetron to the
wave guide.
6. Take out the magnetron very carefully.
7. Remove screws from the back panel.
8. Take out the fan motor.
9. Remove the oven lamp by rotating to pull out
from hole of air cover.
Samsung Electronics
4-1
Lamp
Magnetron
H. V. Trans H. V. Capacitor
Screw
Thermo S/W
Fan Motor
4. Disassembly & Reassembly
4-1 Replacement of Magnetron, Motor Assembly and Lamp
4-2 Replacement of High Voltage Transformer
H. V. Trans
Screws
PRECAUTION
There exists HIGH VOLTAGE ELECTRICITY with high current capabilities in the circuits of the HIGH VOLTAGE TRANSFORMER
secondary and filament terminals. It is extremely dangerous to work on or near these circuits with the oven energized.
DO NOT measure the voltage in the high voltage circuit including filament voltage of magnetron.
PRECAUTION
Never touch any circuit wiring with your hand nor with an
insulated tool during operation.
1. Discharge the high voltage capacitor.
2. Disconnect all the leads from the high voltage transformer.
3. Remove the mounting bolts on the high voltage transformer.
4. When replacing, connect the leads correctly and firmly.
NOTE 1 : When removing the magnetron, make sure that its antenna does not hit any adjacent parts, or it
may be damaged.
NOTE 2 : When replacing the magnetron, be sure to remount the magnetron gasket in the correct position
and make sure the gasket is in good condition.