Installation
Installation
English
16
Alcove or closet installations
WARNING
• The dryer must be exhausted to the outside to reduce the risk of fire when installed in
an alcove or closet.
• No other fuel-burning appliance should be installed in the same closet as the dryer.
Minimum clearances between the dryer and adjacent walls or other surfaces:
Sides
1 in. (25 mm)
Rear
5.9 in. (150 mm)
Top
17 in. (432 mm)
Closet front
2 in. (51 mm)
Installation with pedestal
A
C
B
D
F
E
A
53.7 in (1365 mm)
D
27 in. (686 mm)
B
32.5 in. (825 mm)
E
46.9 in (1192 mm)
C
5.9 in. (150 mm)
F
52.2 in. (1326 mm)