Samsung FH052EAMT Installation Manual Download Page 3

Preparation for installation  . . . . . . . . . . . . . . . . . 4

Deciding on where to install the indoor unit   . . . 5

Ceiling installation   . . . . . . . . . . . . . . . . . . . . . . . 8

Floor installation   . . . . . . . . . . . . . . . . . . . . . . . . 9

Purging the unit  . . . . . . . . . . . . . . . . . . . . . . . . 10

Connecting the refrigerant pipe   . . . . . . . . . . . . 11

Cutting / Flaring the pipes   . . . . . . . . . . . . . . . . 12

Performing leak test & insulation  . . . . . . . . . . . 13

Drain hose installation  . . . . . . . . . . . . . . . . . . . 14

Connecting the connection cord   . . . . . . . . . . . 15

Assigning address to indoor unit   . . . . . . . . . . . 16

Troubleshooting   . . . . . . . . . . . . . . . . . . . . . . . 18

C

C

C

C

E

E

E

E

II

II

LL

LL

II

II

N

N

N

N

G

G

G

G

//

//

FF

FF

LL

LL

O

O

O

O

O

O

O

O

R

R

R

R

TT

TT

Y

Y

Y

Y

P

P

P

P

E

E

E

E

II

II

N

N

N

N

S

S

S

S

TT

TT

A

A

A

A

LL

LL

LL

LL

A

A

A

A

TT

TT

II

II

O

O

O

O

N

N

N

N

Chapter

E-

3

ENGLISH

Summary of Contents for FH052EAMT

Page 1: ...sistemático Refrigeración y Calefacción Climatiseur numérique multifonctionnel Refroidissement et Chauffage Sistema Aria Condizionata Raffreddamento e Riscaldamento Sistema Ar Condicionado Refrigeração e Aquecimento Klimaanlage System Kühlen und Wärmen ÛÙËÌ ÏÈÌ ÙÈÛÌÔ æ ÍË Î È ÚÌ ÓÛË ëËÒÚÂÏÌ È ÇÓÁ Û Ì È äÓÌ ËˆËÓÌ éıÎ Ê ÂÌËÂ Ë Ó Ó Â ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E S F I P D G R DB98 1...

Page 2: ...on 8 Floor installation 9 Purging the unit 10 Connecting the refrigerant pipe 11 Cutting Flaring the pipes 12 Performing leak test insulation 13 Drain hose installation 14 Connecting the connection cord 15 Assigning address to indoor unit 16 Troubleshooting 18 C C C CE E E EI I I IL L L LI I I IN N N NG G G G F F F FL L L LO O O OO O O OR R R R T T T TY Y Y YP P P PE E E E I I I IN N N NS S S ST T...

Page 3: ...aring the pipes 12 Performing leak test insulation 13 Drain hose installation 14 Connecting the connection cord 15 Assigning address to indoor unit 16 Troubleshooting 18 C C C CE E E EI I I IL L L LI I I IN N N NG G G G F F F FL L L LO O O OO O O OR R R R T T T TY Y Y YP P P PE E E E I I I IN N N NS S S ST T T TA A A AL L L LL L L LA A A AT T T TI I I IO O O ON N N N Chapter E 3 ENGLISH ...

Page 4: ...ller Battery Remote Controller Holder Pattern sheet Plate Hanger Installation Manual Owner s Instructions Cable Tie OWNER S INSTRUCTIO NS MANUAL DE INSTRUCCIO NES ISTRUZIONI PER L USO MANUAL DE INSTRUÇÕES MANUEL D UTILISATION GEBRAUCHSANWEISUN G Splut type Room Air Conditioner Aire acondicionado doméstico sistema Split Condizionatore d aria per ambienti ad unità Separate Aparelho de ar condicionad...

Page 5: ...e gas alkaline substances present in the air Avoid location where obstacles preventing good air circulation are present Noise prevention should be considered in determining the unit s location The structure where the unit is to be installed should be strong enough to support the weight of the unit Do not install the unit where it will be exposed to direct sunlight E 5 ENGLISH Space Requirements fo...

Page 6: ...Deciding on where to install the indoor unit cont E 6 45 50 240 200 650 197 922 1000 Drawing of the indoor unit Unit mm Back side ...

Page 7: ...E 7 ENGLISH 50 44 Pipe outlet bottom side Drain hose outlet Wiring hole Air intake hole Ø50 ...

Page 8: ...nstall threaded rod onto anchor bolt expansion bolt to long enough to suspend the unit right below the dropped ceiling and the install the unit suspending on the threaded rod Ensure that the ceiling is strong enough to support the weight of the indoor unit Before hanging the unit test the strength of each attached suspension bolt IMPORTANT Use the pattern sheet to select pipe directions N N N No o...

Page 9: ...he outdoor for smooth water flow 2 Install the hanging plate according to the distance and mount it 3 Install the unit and be sure to arrange the drain hose so that it is leveled lower than the drain hose connecting port of the indoor unit 1000 793 45 50 650 101 Use the pattern sheet to select pipe directions N N N No o o ot t t te e e e Drain hose Drain hose 300mm or more 300mm or more Back side ...

Page 10: ...g the assembly piping To purge the inert gas proceed as follows Unscrew the caps at the end of each pipe Result All inert gas escapes from the indoor unit To prevent dirt or foreign objects from getting into the pipes during installation do NOT remove the caps completely until you are ready to connect the piping N N N No o o ot t t te e e e ...

Page 11: ...to protect the condensate water on the outside of pipe falling onto the floor and the efficiency of the unit will be better 2 Cut off any excess foam insulation 3 Be sure that there must be no crack or wave on the bended area 4 It would be necessary to double the insulation thickness 10mm or more to prevent condensation even on the insulator when if the installed area is warm and humid 5 If the pi...

Page 12: ...orrectly 2 To prevent any gas from leaking out remove all burrs at the cut edge of the pipe using a reamer 3 Slide a flare nut on to the pipe and modify the flare 4 Check that the flaring is correct referring to the illustrations below for examples of incorrect flaring 5 Align the pipes and tighten the flare nuts first manually and then with a wrench applying the following torque 6 Outer Diameter ...

Page 13: ...top valve of the outdoor unit inject nitrogen gas into refrigerant pipe to reach 28kgf cm2 1 Purge nitrogen gas after finishing leak test 3 By using soap bubbles check leak on flare nut connection of pipes 2 Wind insulating tape around the pipes 2 Finish wrapping insulating tape around the rest of the pipes leading to the outdoor unit 3 Always make the seam of pipes face upwards N N N No o o ot t ...

Page 14: ...l check that none of the following situations occur If draining pipe is not too long It may be extended the draining pipe by connecting as following figure The hose must NOT slope upwards The end of the drain hose must NOT be placed in water Do NOT bend the hose in different directions Keep a clearance of at least 5 cm between the end of the hose and the ground Do NOT place the end of the drain ho...

Page 15: ...the connection cord through the side of the indoor unit and connect the cable to terminals refer to the figure below 2 Route the other end of the cable to the outdoor unit through the ceiling the hole on the wall 3 Reassemble the electrical component box cover carefully tightening the screw 4 E 15 ENGLISH Indoor Unit Outdoor Unit Communication Power Next Indoor unit Communication Next Indoor unit ...

Page 16: ...ized controller 4 If you install optional accessories such as the wired remote controller centralized controller etc see an appropriate installation manual 5 If an optional accessory is not installed you do not have to set the RMC address However adjust K1 and K2 switches of the SW03 DIP switch to ON position in this case 6 Set the MAIN address by adjusting the rotary switch SW01 from 0 to F Each ...

Page 17: ...of the indoor unit connected to the wired remote controller to OFF position MAIN SW01 address RMC SW02 address 0 0 Switch Indoor unit Indoor unit 1 1 0 Indoor unit 2 E 17 ENGLISH Example Setting up option switches when installing 2 indoor units Communication cable Wired remote controller INDOOR UNIT 2 K9 SW05 SW04 RMC SW02 SW01 MAIN K10 K11K12 K5 K6K7K8 SW03 K1 K2K3K4 K9 SW05 SW04 RMC SW02 SW01 MA...

Page 18: ...rror of outdoor unit Displayed on the indoor unit which is operating Error of peripherals option set up EEPROM error EEPROM option error Error of the indoor unit sensor Error of the indoor unit pipe sensor Error of the outdoor unit pipe sensor Freeze prevention control Errors occur during 6th detection Communication error Transmitter wired remote control Communication error between indoor units X ...

Page 19: ...T error of eva in sensor in indoor unit EEPROM error EEPROM option error Error of outdoor unit Communication errors Displays related to indoor unit x 0 F For the details refer to the installation manual of the outdoor unit Remark The order of priority EA Eb Cx dx ox qx rx tx Ux Eo In case that the same error displays from multi indoor units the one having the faster address has the priority x x x ...

Page 20: ... Parts List 21 O O O OP P P PT T T TI I I IO O O ON N N NA A A AL L L L A A A AC C C CC C C CE E E ES S S SS S S SO O O OR R R RI I I IE E E ES S S S Chapter E 20 ...

Page 21: ... Transmitter communicationcable 1 Transmitter Accessories Owner s instructions 1 Installation manual 1 Owner s instructions 1 Installation manual 1 Installation manual 1 Function controller 1 Cable tie 2 Cable clamp 6 M4x16 tapped screw 7 Function Controller Accessories Owner s instructions 1 Installation manual 1 Wireless remote controller 1 Battery 2 Remote control holder 1 STS 2S 2x10 tapped sc...

Page 22: ...ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR QUESTO CONDIZIONATORE D ARIA È PRODOTTO DA ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR DIESE KLIMAANLAGE IST FABRIZIERT VON AYTH H Y KEYH KATA KEYA THKE A O ùíéí äéçÑàñàéçÖê àáÉéíéÇãÖç îàêåéâ ...

Reviews: