Setting the Security Function 

This function prevents intrusion from outside while the residents are out.  Once set, it 
generates an alarm sound when the door lock is operated from inside. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Activating the 

Security 

This alarm sounds if the [OPEN] button 
is pressed, or the manual switchgear is 
turned counterclockwise while the 
security function is being activated. 

[Inside] 

"Toot~, toot~, toot~" 
(for 5 minutes) 

Setting the 

Securit

Press and hold the [#] button on the 
outdoor unit for 3 seconds while the 
door is being locked.

Enter the password and press the [

¹

button to set the security function. 

"Too~~t, 
too~~t"

"Too~~~t" 

Expose the registered card to the card 
reader, or enter the password, and then 
press the [

¹

] button. 

[Outside] 

Releasing the 

Securit

Or

The security function is automatically released when the locked door is opened from 
outside by entering the registered password or exposing the card to the card reader. 

Summary of Contents for EZON SHS-1320

Page 1: ......

Page 2: ......

Page 3: ...d to lock it manually Double locking function adds security The double locking function adds security by preventing the door from being opened from outside at night or at times when extra security is needed Pranks played by children and juveniles can be prevented When an unregistered card is used or when an invalid password is entered more than 3 time consecutively an alarm sound is generated and ...

Page 4: ...Card 11 Password Registration and Change 12 RF Card Registration 14 Deleting the Card 16 Opening the Door from Outside with a Password 17 Opening the Door from Outside with a RF Card 18 Opening Locking the Door from Inside 19 Additional Functions 20 Double Security Mode Setting 20 Automatic Manual Locking Setting 21 Sound Setting and Releasing 22 Alarm Sound Emergency Sound 23 Troubleshooting 27 O...

Page 5: ...ing Information given under this heading is information the user must be aware of to prevent physical harm Caution Information given under this heading is information the user must be aware of to prevent service problems or system damage Note Information given under this heading provides additional information relating to the text in this manual Description of Symbols General warning or caution Pr...

Page 6: ...not function properly Make sure that no unauthorized person has the access to the password To minimize the risk of burglary it is recommended that you periodically change the password Do not operate the product with wet hands and keep liquids such as water or drinks away from the product or the product may malfunction or be damaged Do not use the excessive force or sharp objects to push the door l...

Page 7: ... immediately after they run out of power and never mix new batteries with used ones This can cause reduction of product life or a malfunction in the product Replace the batteries within 1 week after the battery replacement alarm sounds The product can stop operating if the batteries are not replaced in time Do not use water benzene or alcohol when cleaning the product as these fluids can cause pro...

Page 8: ... LR6 Indoor Rubber Pad Indoor Unit Strike Outdoor Unit RF card The product components used may vary depending on the installation environment Indoor Unit Fastening Bolts OH M4X32 2EA Strike and Fastening Panel Fastening Bolts BH 4 2X20 8EA Indoor Unit Fastening Bolts PH M4X33 2EA Outbody Fastening Rotating Prevention Bolt LENCH BOLT M4 0 L4 8 ...

Page 9: ...ays how the door lock operates including reading a card 3 Card Reader The Card Reader is used to recognize a card before opening the door Touch the number pad to operate the Card Reader 4 External Power Contact Power can be supplied from the emergency battery after the main batteries have been completely discharged 9V battery Number Pad Turned Off Number Pad Turned On Number Pad External Power Con...

Page 10: ...rom indoor or outdoor 5 Deadbolt This makes the door hooked into a doorframe and locked 6 Door Opening ensor This sensor detects opening and closing of the door in Automatic Locking mode 7 Automatic Manual Locking Toggle Switch This switch is used to switch between Automatic Locking and Manual Locking If it is set for Automatic Locking the door is automatically locked when closed If it is set for ...

Page 11: ...batteries are not replaced Although actual battery life differs depending on the manufacturer date of production and operation environment four 1 5V AA alkaline batteries can last for seven months based on an average of 10 uses per day Battery Life Melody 4 AA batteries If the poles of the batteries are not placed properly the door lock will not operate normally Liquid leaks from batteries can dam...

Page 12: ...sing 9V Battery Buy an emergency battery 9V at the nearest store 3 Opening the Door Using the Emergency Battery Place the RF card on the card reader or enter the password while the 9V battery is connected to the external power contact of the outdoor unit Or Password Entry The door is not opened Recognition of a Card Or As the alkaline batteries offer longer life they are recommended over the manga...

Page 13: ...d card are erased 1 Opening the Cover from inside Lightly press the battery cover and pull it down in the direction of the arrow mark 2 Pressing the Registration Button from inside Press and hold the Registration button for 10 seconds or longer Successful Toot Toot toot Toot toot toot toot sounds are generated 3 Entering the Password from outside Press the registered password or 4560852580 and the...

Page 14: ...y press the Registration button 2 Entering the Current Password from outside Enter the current password 12345 after initialization and press the button 3 Entering a New Password from outside Enter the new password 5 to 12 digits and press the button To prevent burglary it is recommended to use a password of 6 digits or longer Only numbers between 0 and 9 can be used Registering or changing the pas...

Page 15: ...ith a Password on page 17 Too t Too t Manage your password with care so that unauthorized people will not have access to it Regularly changing your password can reduce the risk of it being leaked A registered password cannot be deleted Change the password to a new one or initialize it to delete all registered data password and RF card and then reregister them Check if the new password works proper...

Page 16: ...t and briefly press the Registration button 2 Entering the Password from outside Enter the password and press the button 3 Placing the RF Card in Contact from outside Place the RF card to be registered on the card reader on the outdoor unit You will know the RF card has been registered when a long too t sounds Toot Registering or changing the password is available while the door is open Too t toot...

Page 17: ... on page 18 Registering Additional RF Cards Continue Registration Registration at another Time To register an additional RF card after the registration process is terminated repeat the registration process with the card To register multiple RF cards lightly press another RF card to the card reader within 10 seconds of registering the previous card If another card is not exposed to the card reader ...

Page 18: ...not be individually deleted All card information is deleted when the card delete function is used Previously registered cards cannot be used to open the locked door after they are deleted Toot Toot toot Successful Too t sounds are generated Failed Toot sound is generated Register new RF cards after deleting the card data To open the locked door from outside after deleting card data use the registe...

Page 19: ...lease refer to Double Security Mode Setting on page 20 to change the double security mode to the common security mode The password must be entered while the number pad is illuminated If the light is turned off touch the Number Pad and reenter the password If the wrong password is entered press the button to cancel the entry and start from the beginning If the wrong password is entered 3 times cons...

Page 20: ...e door will be opened after 1 second Place the card on the card reader Successful Too t Failed Toot Touch the Number Pad The card reader will operate properly when the RF card is placed within 30mm 20mm and 10mm of the card reader respectively The recognition distance may differ depending on the card manufacturer A toot alarm sound is generated when an unregistered card is placed or the card is no...

Page 21: ...t is locked Press the OPEN button to lock the door when it is closed in Manual Locking mode Too t Too t Turn the manual switchgear counterclockwise to make its green part appear while the door is locked Turn the manual switchgear clockwise to make its red part appear in Manual Locking mode while the door is closed Opening the Door Manually Locking the Door Manually ...

Page 22: ...ode Setting 7 button Double Security Mode 9 button Common Security Too t Briefly press the Registration button on the indoor unit Too t Double Security Mode This can prevent the password from being exposed by pressing any two numbers for authentication before pressing the password Setting the Double Security Mode is available while the door is open The double security mode is set when the product ...

Page 23: ...oot toot are generated every 15 seconds This alarm sound is not generated in Manual Locking mode The door is automatically locked again if the closed door is not opened within 7 seconds of being unlocked using the password or card For security reasons ensure that the door is locked after locking the door in Manual Lock mode since it is not automatically locked after being closed Automatic Mode The...

Page 24: ... pressed after the 0 3 button is pressed Sound Function 0 Button Mute 1 Button 1 Step 2 Button 2 Step 3 Button 3 Step Too t Briefly press the Registration button on the indoor unit Toot 0 Button All sounds except the alarm sound are deactivated 1 3 Button All sounds are activated and the sound gets louder as the step goes up In registration mode sound is generated regardless of the current setting...

Page 25: ...fter 1 minute Following this the lock is released from inactive mode This alarm will sound if an attempt is made to open the door with an unregistered card or if a wrong password is entered three times in a row The alarm sound is generated and the door lock is deactivated for 1 minute While the door is in this inactive mode a single toot sound is generated every 10 seconds and seven consecutive to...

Page 26: ...eing activated Inside Toot toot toot for 5 minutes Setting the Security Press and hold the button on the outdoor unit for 3 seconds while the door is being locked Enter the password and press the button to set the security function Too t too t Too t Expose the registered card to the card reader or enter the password and then press the button Outside Releasing the Security Or The security function ...

Page 27: ...orcefully opened while locked the door opening sensor detects it and generates the alarm sound Toot toot toot for 5 minutes Open the battery cover of the indoor unit and take out the batteries or press the Registration button Expose the registered card to the card reader or enter the password and then press the button Inside Outside Or When fire occurs the temperature sensor detects it and flashes...

Page 28: ...ed even if the OPEN button is pressed from inside while the double locking function is set But the door can be opened if the manual switchgear is turned counterclockwise When the Number Pad is touch the door cannot be opened while the alarm sound is generated Too t too t Please be cautious since the door cannot be opened from outside when this function is set Particularly be careful of children ac...

Page 29: ...ferring to Password Registration and Change in the user guide P 12 13 The RF card cannot be registered When registering multiple cards continuously the next card must be placed on the card reader within 10 seconds of the previous card P 14 15 The door cannot be opened even after entering the password followed by the button Check that the registered password has been correctly entered If number but...

Page 30: ...ing closed Check to ensure that Automatic Locking mode has been set If the operation mode is set to Manual Locking touch the Number Pad to lock the door If the door does not automatically lock when in Automatic Locking mode then the door lock is installed improperly Contact the digital door lock distributor to have it reinstalled The automatic locking function will not work if the batteries are co...

Page 31: ...ere s no response when the Number Pad is touched Press the hole on the right side of the external power contact on the outdoor unit with a pin If there s still no response after taking the measures above please call the nearest service center ...

Page 32: ...r counterclockwise The door opens Closing the Door from Insider Automatic Mode Press the Open button while the door is opened The door locks Manual Mode Turn the manual switchgear clockwise The door locks Opening the Door from Outside Double Security Mode RF card T ouch the Number Pad Expose the card to the reader within 5 seconds Password T ouch the Number Pad Enter any two numbers Enter the pass...

Page 33: ... Release Enter the password or place the card Emergency Sound Deactivation from Inside Press the Registration button Emergency Sound Deactivation from Outside Enter the password or place the card Double Locking Setting Turn the double locking lever to the direction Double Locking Release Turn the double locking lever to the direction ...

Page 34: ...its Product Dimensions Outdoor Unit 68 7 mm W 175 1 mm H 21 5 mm D Indoor Unit 180 7 mm W 91 5 mm H 48 mm D RF card 25 0 mm W 35 0 mm H 4 0 mm D The content of this manual is subject to change without prior notice to the user in order to enhance performance of the product Product Name Model Name Wireless device using extremely low power radio SHS 1320 Certificate Number SCT SHS 1320 Trade Name of ...

Page 35: ...31 ...

Page 36: ...제품 보증서 ...

Page 37: ......

Reviews: