Troubleshooting_39
Check Type
Check Mode
Checking Method
Corrective actions
Detergent is not
dispensed.
None
1. Check whether detergent is inserted into the dispenser.
- Check whether there is detergent in the Dispenser.
2. Check the connections for the Dispenser connector.
- Reconnect the Dispenser connector.
3. Check the resistance of the Dispenser.
Measure the resistance between pin 1 (pink) and pin 2 (gray)
of the main PBA CN6 connector
(Remove the connector before measuring.)
Normal: Approx. 16
●
Faulty: Replace the Dispenser.
Ω