56 _ Troubleshooting
Error Type
Error mode
Checking method
Corrective actions
2YHUÀRZ
error
OE
&KHFNWKHFRQQHFWLRQVIRUWKH2YHUÀRZ6HQVRUFRQQHFWRU
5HFRQQHFWWKH2YHUÀRZ6HQVRUFRQQHFWRU
2. Check whether the Water Valve operates normally. Use
d07 Display mode.
- See “4E Error”.
3. Check whether water is supplied (even small amounts) in
the intervals when the Water Valve is not operating.
- Remove foreign material from the Water Valve.
- If you cannot remove the foreign material from the Water Valve, replace it.
(UURURFFXUUHQFHDIWHUFRQ¿UP0HWKRG
- Assy Case Brake replace.
Thermistor
Error
tE
1. Check the connections for the Thermistor connector
- Reconnect the Thermistor connector.
2. Check whether the Thermistor is operating normally.
- Measure the voltage between both ends of the
Thermistor.
Normal: 0.05 to 4.95V
- Measure the resistance between both ends of the
Thermistor
: Remove the connector before measuring.
(See the Table right.)
Thermistor table
Temp(
ఁ
)
5HVLVWDQFHNȍ
5
125.814
10
98.360
15
77.480
20
61.477
25
49.120
30
39.510
35
31.985
40
26.053
45
21.347
50
17.590
55
14.573
60
12.136
65
10.157
70
8.541
- Faulty: Replace the Thermistor.
- Normal: Replace the Main PBA assy