Installation
English
30
Installation
NOTE
• During or after the test, the internal drum is hot. Use caution to prevent burns. The
Vent Blockage Test is used to check for problems in the current duct system when the
dryer is installed for the first time.
• If the test result displays check code (the duct system is blocked ), refer to the “
” section below, and
then take proper measures to correct any problems. If the test is suspended, it could
result in incorrect results. Follow the proper procedures when testing the dryer.
• Even if the test result is normal (“
0
”), the duct system could be blocked slightly.
Properly install all duct work according to the installation instructions in this manual.
Installation check codes
Check code
Meaning
Solution
0
Vent condition is good.
Clg (Cg)
The vent is clogged.
1.
Clean the lint filter.
2.
Check your vent condition.
* You must take measures (such as
cleaning) through expert personnel.
C80 (C8)
About 80 % of the vent is clogged.
(This may decrease the drying
performance.)
C90 (C9)
Over 90 % of the vent is clogged.
(This may lead to poor drying
performance or cause malfunction)
Ct
The internal temperature of the
dryer is too low (below 32 °F (0 °C))
or too high (over 104 °F (40 °C))
and therefore vent blockage cannot
be detected.
Leave the dryer at room
temperature (41~95 °F (5~35 °C))
for an hour and check again.
tC
Temperature sensor error.
Contact a service center.
C1
Unit is detecting items inside the
drum or there is an error on the
dry sensor.
Remove items from the drum and
check again.
If the problem continues, contact a
service center.
dC
Unit is detecting door is open.
Close the door properly and check
again.
If the problem continues, contact a
service center.
Untitled-17 30
8/4/2020 6:47:25 PM
Summary of Contents for DVE45T6005 Series
Page 1: ...Dryer User manual DVE G 45T6005 DVE G 45T6000 Untitled 17 1 8 4 2020 6 47 18 PM ...
Page 61: ...Memo Untitled 17 61 8 4 2020 6 47 38 PM ...
Page 62: ...Memo Untitled 17 62 8 4 2020 6 47 38 PM ...
Page 63: ...Memo Untitled 17 63 8 4 2020 6 47 38 PM ...
Page 125: ...Mémo Untitled 19 61 8 4 2020 7 02 15 PM ...
Page 126: ...Mémo Untitled 19 62 8 4 2020 7 02 15 PM ...
Page 127: ...Mémo Untitled 19 63 8 4 2020 7 02 15 PM ...
Page 129: ...Secadora Manual del usuario DVE G 45T6005 DVE G 45T6000 Untitled 18 1 8 4 2020 6 56 45 PM ...
Page 190: ...Notas Untitled 18 62 8 4 2020 6 57 07 PM ...