Installation requirements
Installation requirements
English
16
Mobile home installation
The installation of the dryer in mobile homes must conform to the Manufactured Home
Construction and Safety Standard Title 24 CFR, Part 3280 {formerly the Federal Standard
for Mobile Home Construction and Safety, Title 24, HUD (Part 280), 1975} for the United
States) or CSA Standards Z240 (for Canada).
When installing a dryer in a mobile home, you must make provisions for anchoring the
dryer to the floor.
Locate the dryer in an area that has adequate fresh air.
A minimum of 72 in² (465 cm²) of unobstructed space is required.
Call 1-800-SAMSUNG (726-7864) for information on purchasing the Floor Anchoring Kit
as an accessory.
All mobile home installations must be exhausted to the outside with the exhaust duct
termination securely fastened to the mobile home structure, using materials that will not
support combustion.
The exhaust duct may not terminate underneath the mobile home.
See Exhausting section for more information.