Installation
English
18
Engl
ish
Alcove or closet installation
For alcove or closet installation, the dryer requires the following minimum clearances:
Sides
Top
Front
Rear
25 mm
25 mm
490 mm
50 mm
If installing the dryer with a washing machine, the front of the alcove or closet must have an unobstructed
air opening of at least 550 mm. Minimum size of installation space: 3.9m
3
Step-by-step installation
Before you install your dryer, make sure you have read
Installation requirements
on page
17
.
STEP 1
Select a location
Location requirements
Select a level, well-constructed surface that will withstand vibrations. Select a location where a grounded,
3-prong outlet is easily accessible.
For convenience, consider installing the dryer next to your washing machine.
WARNING
• Install the dryer indoors only.
• Do not install the dryer in areas exposed to the weather.
•
The ambient temperature for installation is 5~35℃.
-
If the ambient temperature is low enough to freeze the condensed water in the dryer and hoses, the
dryer may not operate, or can be damaged.
-
Make sure that the temperature where the dryer is installed is not outside the recommended
temperature range. Drying performance may be reduced.
-
Make sure not to install the dryer in an enclosed environment or near any heat producing appliances.
• Do not install the dryer where gas may leak.
• Do not use in a poorly ventilated space or area.
• Use only a power source connected to the wall.
B-PJT_DV5000B_WEB_English.indd 18
2022/7/30 11:07:07
Summary of Contents for DV9 BBA Series
Page 52: ...Poznámka B PJT_DV5000B_WEB_Czech indd 52 2022 8 27 15 27 13 ...
Page 106: ...Poznámky B PJT_DV5000B_WEB_Slovak indd 52 2022 8 27 15 10 01 ...
Page 109: ...Heat Pump Dryer Usermanual DV9 BBA B PJT_DV5000B_WEB_English indd 1 2022 7 30 11 07 04 ...
Page 159: ...B PJT_DV5000B_WEB_English indd 51 2022 7 30 11 07 18 ...
Page 160: ...B PJT_DV5000B_WEB_English indd 52 2022 7 30 11 07 18 ...