English - 21
02
INST
ALL
ATION
6.
Review the “
” section on page
Remove the pipe thread protective cap. Apply a pipe joint compound or about 1½ wraps of Teflon tape over
all threaded connections.
The pipe joint compound must be resistant to the actions of any liquefied petroleum gas.
Connect the gas supply to your dryer. An additional fitting is required to connect the 3/4” (1.9 cm) female
thread end of a flexible connector to the 3/8” (1 cm) male threaded end on the dryer.
Securely tighten the gas line fitting over the threads.
Turn on the gas supply.
Check all gas connections for leaks using a soap solution.
If bubbles appear, tighten the connections and recheck. DO NOT use an open flame to check for gas leaks.
Door reversal
Type 1
1.
Unplug the power cord.
2.
Remove two door hinge screws.
3.
Lift the door and remove it.
4.
Remove two screws from the frame front.
5.
Remove the two screws from the opposite side of the door hinge.
6.
Remove the two screws from the holder lever.
7.
Reassemble the two screws on the inside holes.