Installing your dryer

 

_9

If the new dryer is installed into an existing exhaust system you must make 
sure:

• 

The exhaust system meets all local, state, and national codes.

• 

That a flexible plastic duct is not used.

• 

To Inspect and clean all lint buildup from inside the existing duct.

• 

The duct is not kinked or crushed.

• 

The exhaust hood damper opens and closes freely.

The static pressure in any exhaust system must not exceed 0.83 inches of water column, or be 
less than 0.
This can be measured with the dryer running with a manometer at the point where the exhaust 
duct connects to the dryer. A no-heat setting should be used. The dryer tumbler should be 
empty and the lint filter clean.

IMPORTANT TO INSTALLER

Please read the following instructions carefully before installing the dryer. These instructions should be kept 
for future reference.

REMOVE THE DOOR FROM ALL DISCARDED APPLIANCES TO AVOID THE DANGER OF A CHILD 
SUFFOCATING.

LOCATION CONSIDERATIONS

The dryer should be located where there is enough space in front for loading the dryer, and enough space 
behind for the exhaust system. This dryer is factory-ready for rear exhaust. To exhaust out the bottom or 
the left, use the accessory exhaust kit. Instructions are included with the kit. It’s important to make sure the 
room has enough fresh air. The dryer must be located where there is no air-flow obstruction.
On gas dryers, adequate clearance as noted on the data plate must be maintained to ensure adequate air 
for combustion and proper dryer operation.
THE DRYER MUST NOT BE INSTALLED OR STORED IN AN AREA WHERE IT WILL BE EXPOSED TO 
WATER AND/OR WEATHER. THE DRYER AREA IS TO BE KEPT CLEAR OF COMBUSTIBLE MATERIALS, 
GASOLINE, AND OTHER FLAMMABLE VAPORS AND LIQUIDS. A DRYER PRODUCES COMBUSTIBLE 
LINT. THE AREA AROUND THE DRYER SHOULD BE KEPT LINT-FREE.

ALCOVE OR CLOSET INSTALLATION

The dryer must be exhausted to the outside to reduce the risk of fire when installed in an alcove or 
closet.

• 

No other fuel-burning appliance should be installed in the same closet as the dryer.

• 

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED TO THE OUTDOORS. 
See EXHAUST INFORMATION section.

• 

Minimum clearances between the dryer and adjacent walls or other surfaces are: 
2” in front, 17” on top, 1” on either side, and 2.375” in the back.

• 

The closet front must have two unobstructed air openings for a combined minimum total area of 72 in² 
with 3” minimum clearance on the top and bottom. A louvered door with equivalent space clearance is 
acceptable.

01 Installing your dryer

WARNING

WARNING

Summary of Contents for DV337 SERIES

Page 1: ...and Electric Dryer user manual imagine the possibilities Thank you for purchasing a Samsung product To receive a more complete service please register your product at www samsung com global register D...

Page 2: ...e sure you have everything necessary for proper installation 1 A GROUNDED ELECTRICAL OUTLET is required See Electrical Requirements 2 A POWER CORD for electric dryers except Canada 3 GAS LINES if a ga...

Page 3: ...amper to prevent back drafts and entry of wildlife Never use an exhaust hood with a magnetic damper The hood should have at least 12 inches 30 5 cm of clearance between the bottom of the hood and the...

Page 4: ...ft use the accessory exhaust kit Instructions are included with the kit It s important to make sure the room has enough fresh air The dryer must be located where there is no air flow obstruction On ga...

Page 5: ...haust duct termination securely fastened to the mobile home structure using materials that will not support combustion The exhaust duct may not terminate underneath the mobile home See Exhausting sect...

Page 6: ...ediately upstream of your dryer s gas supply connection Your dryer must be disconnected from the gas supply pipe system during any pressure testing of the system DO NOT reuse old flexible metal gas li...

Page 7: ...Canada and local codes and ordinances GROUNDING This dryer must be grounded In the event of malfunction or breakdown the ground will reduce the risk of electrical shock by providing a path of least re...

Page 8: ...pere with three No 10 copper wire conductors terminated with closed loop terminals open end spade lugs with turned up ends or with tinned leads 1 size of the conductors and the type of cord 2 3 4 1 9...

Page 9: ...ced for a 3 WIRE SYSTEM CONNECTION The dryer frame is grounded to the neutral conductor at the terminal block A 4 WIRE SYSTEM CONNECTION is required for new or remodeled construction mobile homes or i...

Page 10: ...k screws Tighten screws 5 Tighten the strain relief screws 6 Insert the tab of the terminal block cover into your dryer s rear panel slot Secure the cover with a hold down screw 1 External ground conn...

Page 11: ...rapping screws 3 Keep ducts as straight as possible 4 Clean all old ducts before installing your new dryer Be sure vent flap opens and closes freely Inspect and clean the exhaust system annually Don t...

Page 12: ...le the black screw in the other hole 4 Remove two screws on the opposite side of the door hinge 8 Place the door on the other side and reattach it to the dryer 5 Remove two screws from the holder leve...

Reviews: