Causes
Check Point
Heater, main PBA
ㆍ
HE error occurs when the temperature change is 39.2˚F or less within the first 10
minutes after the heating starts
#7. Error Code
7-6. HE (Heater Error)
Symptom
ㆍ
HE error is displayed. (‘Heavy’ + ‘Delicate’ LED On)
Step 1
: Heater
!
Check the connections at the Heater connectors.
"
Check the resistance between both ends of the Heater directly,
or check for the resistance between the red wire of the Heater Relay
and the amber and yellow wires of the Power Relay, respectively.
(
The Voltage : approximately 13.5Ω
If the value is not normal, replace heater.
! '*#$%&!
Step 2
: Main PBA
!
Check for the voltage between Main PBA T101 connector and
T102 connector.
(
The Voltage : approximately AC 120V (while operating)
If the value is not normal, replace heater.