9
GAS MODEL
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
Radiant Sensor(10RS)
Resistance value < 1 Ω
If resistance is infinite, replace Radiant sensor
Igniter(101D)
Resistance value 40~400 Ω
If resistance is infinite, replace Igniter
Gas Valve(25M01A)
Valve 1-2 : Resistance value 1.2K Ω
Valve 1-3 : Resistance value 0.5K Ω
Valve 4-5 : Resistance value 1.2K Ω
If resistance is infinity, replace Valve
Thermostat (60T21 Hi-Limit)230F-50F
Resistance value < 1 Ω
If resistance is infinity, replace Thermostat
THERMISTOR
238.23Ω @ 25 °C 77
(Technical)DV405-02365H-03_EN_130221.indd 9
2013-02-21 �� 5:32:02