safety information

safety information

SEVERE WARNING SIGNS 

If any gas or impurities other than R410A refrigerant come into the refrigerant pipe, 

serious problem may occur and it may cause injury.
Do not spray flammable gases such as insecticide near the air conditioner.

• 

Potential risk of electric shock, fire or unit malfunction.

Do not insert anything such as fingers or branches into the air conditioner vents.

• 

Keep children away from the air conditioner. Potential risk of personal injury.

Do not cut the power plug and connect to a different power cable. 
Never attempt to lengthen the power cable. 

• 

Potential risk of fire or electric shock.

Do not yank the power cable and touch the power plug with hands. 

• 

Potential risk of fire or electric shock.

Never use a damaged power plug, power cable, or loosened power receptacle. 

• 

Potential risk of fire or electric shock.

The electric work must be done by qualified service technician in accordance with the 

national wiring regulations with rated cables.

• 

If the capacity of the power cable is insufficient or electric work have not done properly, electric 

shock or fire may occur.

You should connect the power cable into the power cable terminal and fasten it with a 

clamp. 
Do not connect the air conditioner with heating apparatus or attempt to disassemble, 

remodel or repair it by yourself.

• 

Potential risk of malfunction, electric shock or fire. If repairs are needed, consult the contact center.

Consult the place of purchase or a contact center to disassemble or reinstall the air 

conditioner.

• 

Potential risk of unit malfunction, water leakage, electric shock, or fire.

Consult the place of purchase or contact center to install the air conditioner.

• 

Improper installation carries a risk of unit malfunction, water leakage, electric shock or fire.

• 

If installing in specialty areas, such as a factory complex or saline coastal area, consult the place of 

purchase or contact center for specific installation details.

Install the air conditioner with the support bracket securely fastened to use for an 

extended period of time.

• 

If the air conditioner falls, it may cause personal injury or loss of property.

If the indoor unit gets wet, turn the power off immediately and call your nearest 

contact center.

• 

Potential risk of fire or electric shock.

Install an exclusive circuit breaker and short-circuit breaker for the air conditioner. 

• 

Potential risk of electric shock or fire.

If the power cable is damaged, the manufacturer or a qualified service technician 

must replace it.
Always make sure that the power supply is compliant with current safety standards. 

Always install the air conditioner in compliance with current local safety standards.
Verify that the voltage and frequency of the power supply comply with the 

specifications and that the installed power is sufficient to ensure the operation of any 

other domestic appliance connected to the same electric lines.
The air conditioner must be installed in accordance with national wiring regulations 

and safety regulations wherever applicable.

Summary of Contents for DC24ETSA

Page 1: ......

Page 2: ...your own air conditioner Cost Efficient System Your new air conditioner not only provides maximum cooling power in the summer but can also be an efficient heating method in the winter with the advance...

Page 3: ...pt Do NOT disassemble Do NOT touch Follow directions carefully Unplug the power plug from the wall socket Make sure the machine is grounded to prevent electric shock Call the contact center for help R...

Page 4: ...sult the contact center Consult the place of purchase or a contact center to disassemble or reinstall the air conditioner Potential risk of unit malfunction water leakage electric shock or fire Consul...

Page 5: ...ect the air conditioner from power supply before it is repaired or disassembled CAUTION SIGNS Connect the refrigerant tubes first then the electrical lines when installing the unit Always disassemble...

Page 6: ...l reception error may occur due to the ballast of the lighting apparatus For maximum safety installers should always carefully read the following warnings Do not install the air conditioner in followi...

Page 7: ...onditioner If the remote control is not used for a long period of time remove the batteries to prevent leakage of electrolyte When cleaning the outdoor unit touch the heat exchanger radiator fins with...

Page 8: ...ble and the connection cord of the indoor and outdoor units in the protection tube Connect the power cable to the auxiliary circuit breaker You must keep the cable in a protection tube Keep distances...

Page 9: ...your air conditioner CLEANING AND MAINTAINING THE AIR CONDITIONER 12 12 Cleaning the filter 12 Slim duct type 13 MA duct type 14 Maintaining your air conditioner 14 Periodical checks 15 Internal prot...

Page 10: ...ol or warm with optimal efficiency Please read the user manual to get started and to make the best use of the air conditioner SLIM DUCT TYPE MA DUCT TYPE Your air conditioner may look slightly differe...

Page 11: ...The air conditioner stops heating The air conditioner will operate automatically in De ice mode for 10 minutes The steam produced on the outdoor unit in De ice mode is safe No intervention is required...

Page 12: ...is cleaned with a vacuum or by hand washing Slim duct type 1 Way 1 Slide out the Air filter on the rear side panel to the right side Way 2 Take out the Air filter from the panel 2 Clean the Air filte...

Page 13: ...area For best conditions repeat every two weeks If the Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it in a ventilated area 3 Way 1 Insert the filter b...

Page 14: ...ndoor unit Clean the air filter 1 Clean the condensate drain pan 2 Thoroughly clean the heat exchanger 2 Clean the condensate drain pipe 2 Replace the remote control batteries 1 Outdoor unit Clean the...

Page 15: ...when the heat pump is heating Anti protection of internal battery The compressor will be off to protect internal battery when the air conditioner operates in Cool mode Protect compressor The air condi...

Page 16: ...e for cooling model The fan speed does not change Check if you selected Auto or Dry mode The air conditioner automatically adjusts the fan speed to Auto in Auto Dry mode Timer function does not set Ch...

Page 17: ...IF OUT OF CONDITIONS INDOOR OUTDOOR COOLING 21 C to 32 C 21 C to 54 C 80 or less Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor DRYING 21 C to...

Page 18: ...UESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT Turkey 444 77 11 www samsung com tr SOUTH AFRICA 0860 SAMSUNG 726 7864 www samsung com za U A E 800 SAMSUNG 726 7864 8000 4726 www samsung com a...

Page 19: ...Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com global register Duct Type Series Slim duct MA duct DC18ET DC24ET DC30ET D...

Reviews: