14_
setting up
flat-blade screwdriver (-) Control Lever
Both control levers must be touching the floor
to avoid possible personal injury or property
damage because of tipping.
If the right side is lower, perform the same
procedure, but with the right control lever.
It is difficult to remove the cover leg front from
the refrigerator, so we do not recommend
making small adjustments with the control lever.
Instead, refer to the next page for the best way
to make minor adjustments to the doors.
MAKING MINOR ADJUSTMENTS
TO THE DOORS
Remember, a leveled refrigerator is necessary for
getting the doors perfectly even. If you need help,
review the previous section on leveling the refrigerator.
Adjustment
part
Fixed part
The left door is fixed. To make minor door
adjustments, adjust only the right door.
1.
Pull out the flex door (
1
) to reveal the lower
hinge (
2
).
2.
Insert a philips screwdriver (+) (
3
) into the
shaft (
4
) of the lower hinge.
3.
Adjust the height by turning a philips screwdriver (+)
(
3
) clockwise (
DOWN
) or counterclockwise (
UP
).
When you turn a philips screwdriver (+)
counterclockwise (
), the door will
move up.
CAUTION
3
1
2
3
4
INSTALLING THE WATER
DISPENSER LINE
A water dispenser with a filter is one of the helpful
features on your new refrigerator. To help promote
better health, the water filter removes unwanted
particles from your water. However, it does not
sterilize or destroy microorganisms. You may need to
purchase a water purifying system to do that.
The water line also connects to the ice maker.
For the ice maker to operate properly, water pressure
of 20-125 psi (138 ~ 862 kPa) is required.
If the refrigerator is installed in an area with low water
pressure (below 20 psi), you can install a booster
pump to compensate for the low pressure.
After you have connected the water line, make
sure the water storage tank inside the refrigerator is
properly filled. To do this, press the water dispenser
lever until the water runs from the water outlet.
Water line installation kits are available at
extra cost from your dealer.
We recommend using a water line
installation kit that contains copper tubing
and ¼” compression nut.
Connecting to the water
supply line
1.
First, shut off the main water
supply.
2.
Locate the nearest cold water drinking line and
install the pipe clamp and shut off valve.
Pipe clamp
Cold water line
Shut off valve
DA68-02897A-12.indb 14
2016. 3. 30. �� 2:28