Service Manual
Adjustment and Troubleshooting
4-14
Samsung Electronics
4.1.6.3(d) HVPS Test
Item
Discription
Charger
When select key is pushed, DUTY : x%* message will be displayed.
And then Left/Right arrow is selected, x% is increased or decreased.
And DUTY : x% message will be displayed. * is disappeared.
And then select key is pushed, x%* message will be displayed.
When Upper Level is pushed, * is disappeared.
T1
When select key is pushed, DUTY : x%* message will be displayed.
And then Left/Right arrow is selected, x% is increased or decreased.
And DUTY : x% message will be displayed. * is disappeared.
And then select key is pushed, x%* message will be displayed.
When Upper Level is pushed, * is disappeared.
T2
When select key is pushed, DUTY : x%* message will be displayed.
And then Left/Right arrow is selected, x% is increased or decreased.
And DUTY : x% message will be displayed. * is disappeared.
And then select key is pushed, x%* message will be displayed.
When Upper Level is pushed, * is disappeared.
T2 REVERSE
When select key is pushed, T2 REVERSE On message will be displayed.
If not, T2 REVERSE Off will be.
Dev DC
When select key is pushed, DUTY : x%* message will be displayed.
And then Left/Right arrow is selected, x% is increased or decreased.
And DUTY : x% message will be displayed. * is disappeared.
And then select key is pushed, x%* message will be displayed.
When Upper Level is pushed, * is disappeared.
Dev AC Vpp
When select key is pushed, DUTY : x%* message will be displayed.
And then Left/Right arrow is selected, x% is increased or decreased.
And DUTY : x% message will be displayed. * is disappeared.
And then select key is pushed, x%* message will be displayed.
When Upper Level is pushed, * is disappeared.
Dev AC
When select key is pushed, DUTY : x%* message will be displayed.
And then Left/Right arrow is selected, x% is increased or decreased.
And DUTY : x% message will be displayed. * is disappeared.
And then select key is pushed, x%* message will be displayed.
When Upper Level is pushed, * is disappeared.
Charger
Duty : 50% -> -789V , Range : -81V ~ -1689V
T1
Duty : 50% -> 1159V , Range : 122V ~ 2188V
T2
Duty : 50% -> 2552V , Range : 264V ~ 4730V
Supply DC
Duty : 50% -> -269V , Range : -1V ~ -591V
AC, Vpp
Duty : 50%-> 1210V
, Range : 800V ~ 2160V
Summary of Contents for CLP 350N
Page 25: ...Product specification and feature Service Manual 2 15 Samsung Electronics 2 2 2 2 Main PBA ...
Page 45: ...Product specification and feature Service Manual 2 35 Samsung Electronics ...
Page 143: ...Samsung Electronics Service Manual Exploded Views Parts List 5 16 5 6 LSU Cover 0 1 2 5 4 6 3 ...