4-1-2 Safety Error (Continued)
35 Page
38 Page
38 Page
34 Page
Error Code
Gerneral Function
Solution
Page
Divider Missing
This error occurs when the divider sensing switch
senses that the divider is used at the inappropriate
mode.
Preheating Time Out
This error occurs when the set preheating time, 30
minutes, is over.
It may occur due to a heater’s open, defects of relay
contact point and wiring defects.
Excess of cooking compart-
ment’s temperature
- This error occurs when the temperature of cooking
compartment maintains over 320°C for more than 5
minutes.
- This error occurs when a fire occurs inside cooking
compartment or the temperature cannot be con-
trolled because of sensor’s failure.
Excess of cooking compart-
ment’s temperature
- This error occur immediately after the temperature
of cooking compartment reaches 350°C.
- This error occurs when a fire occurs inside cooking
compartment or the temperature cannot be con-
trolled because of sensor’s failure.
Cooling motor lock sensed
- This error occurs when the temperature sensor on
the Main PCB senses abnormal temperature.
- It occurs 30 ~ 60 minutes after the cooling motor
does not operate.
- It may occur when the cooling motor stops running
by power off during operation of the oven, then it
runs again.
Exess of steam generator
temperature
- This error occurs when the temperature sensor in
the steam generator senses abnormal temperature.
Water valve open sensed
- This error occurs when generator sensor can not
sense the water even though water valve is opened
for 30 sec.
33 Page
36 Page
28 Page