Temperature and Humidity Ranges

ENGLISH

The following table indicates the temperature and humidity ranges, 
within which the air conditioner can be used.

If the air conditioner is used at... 

Then... 

The automatic protection feature may be
triggered and the air conditioner stopped.

High temperature

A water leakage or some other 
malfunction may happen if the heat
exchanger freezes.

Low temperature

Water may condense on and drip from
the surface of the indoor unit if it is used
for a long periods.

High humidity levels

Mode

Outdoor Temperature

Indoor Temperature

Indoor Humidity

Cooling

Drying

21°C to 54°C approx.

21°C to 54°C approx.

21°C to 32°C approx.

21°C to 32°C approx.

80% or less

-

❇ 

If the cooling operation is used at over 33°C(indoor temperature)
then, it does not cool at its full capacity.

Summary of Contents for BC052TBZA

Page 1: ...ER S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D UTILISATION E S F A DB98 05501A 2 Indoor Unit BC052TEZA BC052TBZA BC070TEZA BC070TBZA HC105TEZA HC105TBZA HC140TGZA HC140TFZA HC175TGZA HC175TFZA HC230TGZA HC230TFZA Outdoor Unit BC052TEZX BC052TBZX BC070TEZX BC070TBZX HC105TEZX HC105TBZX HC140TGZX HC140TFZX HC175TGZX HC175TFZX HC230TGZX HC230TFZX ...

Page 2: ...top operation turn off the electrical breaker and consult authorized service personnel DANGER Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner dire...

Page 3: ...oller Buttons and Display 6 The Indicators on the Receiver Display Unit 7 Wired Remote Controller Buttons and Display 8 Centralized Controller 9 RECOMMENDATIONS FOR USE Operating Recommendations 10 Temperature and Humidity Ranges 11 Cleaning Your Air Conditioner 12 Solving Common Problems 14 TECHNICAL SPECIFICATIONS ENGLISH ...

Page 4: ...ction may differ from yours depending on the model Indoor Unit HC105TEZA HC140TGZA HC175TGZA HC230TGZA HC105TBZA HC140TFZA HC175TFZA HC230TFZA Indoor Unit BC052TEZA BC052TBZA BC070TEZA BC070TBZA Air outlet Air inlet Air outlet Air inlet Air inlet Panel option ...

Page 5: ...ZX Outdoor Unit HC105TEZX HC105TBZX Outdoor Unit HC140TGZX HC140TFZX HC175TGZX HC175TFZX Outdoor Unit HC230TGZX HC230TFZX Air inlet Rear ENGLISH Air outlet Connection valve Air outlet Connection valve Connection valve Air outlet Connection valve Air outlet ...

Page 6: ...onditioner does not have function of adjusting air flow direction Therefore the function is not operated even if you press the swing button N N N No o o ot t t te e e e Operating mode Mode selection button Filter Reset button Swing button Not operated On Timer button Off Timer button On Off Timer Set Cancel button Fan speed adjustment button Temperature adjustment buttons Temperature setting Fan s...

Page 7: ...e controller and it is installed on the wall To use the receiver display unit refer to an appropriate manual Filter sign indicator Filter sign indicator Remote control sensor On Off indicator Fan indicator On Off button Timer indicator Fan indicator Timer indicator Remote control sensor On Off button Concealed Type Standard Type ...

Page 8: ...refer to page 12 or 13 Duct type air conditioner does not have function of adjusting air flow direction Therefore the function is not operated even if you press the swing button N N N No o o ot t t te e e e Communication error indicator On Timer setting Off Timer setting Test indicator On Timer button Off Timer button Test button Filter Reset button Mode selection button Temperature adjustment but...

Page 9: ...the wall To use the centralized controller refer to an appropriate manual ENGLISH Operating lamp All On button All Off button On Off indicators On Off buttons Index Operating lamp comes on when at least one air conditioner connected to the centralized controller is operating N N N No o o ot t t te e e e ...

Page 10: ...erating your air conditioner Topic Recommendation If a power failure occurs while the air conditioner is operating the unit will be switched off When the power returns the air conditioner restarts in the previous operation mode Power failure Operating Recommendations ...

Page 11: ... A water leakage or some other malfunction may happen if the heat exchanger freezes Low temperature Water may condense on and drip from the surface of the indoor unit if it is used for a long periods High humidity levels Mode Outdoor Temperature Indoor Temperature Indoor Humidity Cooling Drying 21 C to 54 C approx 21 C to 54 C approx 21 C to 32 C approx 21 C to 32 C approx 80 or less If the coolin...

Page 12: ...move the fixing bracket on the base of air filter kit 1 Pull out the air filter in the direction of the arrow 2 Remove all dust on air filter with a vacuum cleaner or a brush In case of serious dust accumulation put the air filter in warm detergent water and shake it vertically 3 Dry the air filter 4 When you have finished insert the filter into the unit 5 Reinstall the fixing bracket 6 Clean the ...

Page 13: ...fety clips 2 2 Open the front grille about 45 and pull it forward 2 Remove two brackets by unfastening screws 3 Pull out the air filters 4 Remove all dust on air filter with a vacuum cleaner or a brush In case of serious dust accumulation put the air filter in warm detergent water and shake it vertically 5 Dry the air filters 6 When you have finished insert the filter into the original position 7 ...

Page 14: ...de has been selected The room temperature may be too low or too high Dust may be blocking the air filter guard refer to page 12 or 13 for cleaning instructions Check that there is no obstacle in front of the outdoor unit The air conditioner does not operate with the remote controller Wireless Remote Controller Wireless Remote Controller No beep is heard when you press ON OFF on the remote controll...

Page 15: ...0V 50Hz BC105TEZA BC105TEZX 3Ø 380 415V 50Hz HC140TGZA HC140TGZX 3Ø 380 415V 50Hz HC175TGZA HC175TGZX 3Ø 380 415V 50Hz HC230TGZA HC230TGZX 1Ø 220V 60Hz 1Ø 220V 60Hz 1Ø 220V 60Hz BC052TBZA BC052TBZX BC070TBZA BC070TBZX HC105TBZA HC105TBZX 1Ø 220V 60Hz 3Ø 220V 60Hz HC140TFZA HC140TFZX 1Ø 220V 60Hz 3Ø 220V 60Hz 1Ø 220V 60Hz 3Ø 220V 60Hz HC175TFZA HC175TFZX HC230TFZA HC230TFZX ...

Page 16: ...ELECTRONICS THIS AIR CONDITIONER IS MANUFACTURED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR Printed in Korea ...

Reviews: