Installation

Before installation, be sure to check the installation area
for the air conditioner, and drain hose.

Checkpoints prior to installation

Check the cabinet and front grille of the unit for any harmful defects
such as scratches.

1

Be sure to check the power supply.

- Refer to the specifications on the label attached to the unit.

2

Installation Conditions

As the unit is heavy, the wall or window of the installation area should
have sufficient strength and durability for operation of the air conditioner,
and for prevention of any vibration or noise.
If it is weak, reinforcement work should be performed separately.

1

It is advisable to install the air conditioner in the north or west side to
prevent the effect of direct sunlight.
When installing it in the south or east side due to unavoidable 
circumstances, it is advisable to install the sunshade to prevent the 
direct sunlight.
In this case, take care not to cause any hindrance to the flow of outside air.

2

When installing the air conditioner, be sure to obtain sufficient space on
the rear side of the unit for smooth flow of air.
When operating the air conditioner in closed areas such as inner building 
with cooling operation, and result in trouble with the unit.
See the illustration below.

3

500mm

500mm

75mm

min.

300mm

500mm

Fence, wall
or other 
obstacle

150mm min.

“A”

Approx.3

˚

Awning

750mm

◆ 

If the wall is greater than 150mm thick, 

cut the wall back on a 45˚ angle if possible.

100mm or more

45˚

45˚

Model

✴✴✴✴✴✴

N

✴✴

✴✴✴✴✴✴

D

✴✴

✴✴✴✴✴✴

M

✴✴

“A”

180mm

220mm

240mm

E-

14

Outdoor Side

Indoor Side

The appliance must be fixed well by screw or similar method.

Summary of Contents for AW09A0KE

Page 1: ...CA AW12F0 1 3 DAA BA CA DA EA AW14F0 1 3 MAA AB BA CA DA EA AW18F0 1 3 MBA BB BC DA EA EB AW18F0 1 3 MCA CB CC AWT18F0 1 3 MBA BB DA EA EB AW22F0 1 3 MBA CA DA EA AW22F0 1 3 MBB CB DB EB AW24F0 1 3 M...

Page 2: ...items placed on or against it If the power cord is damaged in any way it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard 6 Do NOT...

Page 3: ...N The maximum permissible system impedance at the power junction box is 0 24 ohms Usually the maximum permissible mains impedance will not be exceeded when the branch to the power outlet is fed from a...

Page 4: ...switch Air flow blade swing switch Outer air flow blades up down orientation Air inlet Outside Ventilation lever Inner air flow blades right left orientation The design and shape are subject to chang...

Page 5: ...perature in your room You can also set the fan speed 1 2 To control the direction of the air flow refer to page 7 3 To adjust the temperature turn the temperature control dial to the desired position...

Page 6: ...refer to page 7 3 If you wish to evacuate stale air outside push the ventilation lever on the front of the unit to the right and the open position Result The air inside the room circulates and stale a...

Page 7: ...he blades are in the desired position Hold the inner air flow blades and adjust them to the desired direction 2 Set the air flow blade swing switch to the position Result The inner blades swing automa...

Page 8: ...3 G3 models If the air conditioner is used at Then Higher temperature The automatic protection feature may be triggered and the air conditioner stopped Lower temperature A water leakage or some other...

Page 9: ...air filter back into its original position 4 Wipe the surface of the unit with a neutral detergent and then wipe it again with dry cloth Be sure not to use benzene solvent or other chemical products 5...

Page 10: ...ve the dust on the air filter Before cleaning your air conditioner ensure that it is switched off and unplugged from the wall socket Open the front grille by pulling on the tabs of the unit The remova...

Page 11: ...e 9 or 10 for cleaning instructions Check that there is no obstacle blocking the air flow into or out of the unit PROBLEM The air conditioner does not operate at all The air conditioner does not cool...

Page 12: ...Specifications E 12 Design and specifications are subject to change without notice Model AA AB BA BB BC BD CA CB CC CD DA DB EA EB EC Power Supply 115V 60Hz 220V 60Hz 230 208V 60Hz 200 220V 50Hz 220...

Page 13: ...remove the third grounding prong from the power cord We recommend that you do not use an extension cord or an adapter plug with this appliance Do not change the plug on the power cord of this applian...

Page 14: ...st side to prevent the effect of direct sunlight When installing it in the south or east side due to unavoidable circumstances it is advisable to install the sunshade to prevent the direct sunlight In...

Page 15: ...the rubber cap inserted into the basepan 6 Fix the drain pan as shown in the figure and then connect the drain hose You can use any commercially available drain hose 7 Install the cabinet at the spec...

Page 16: ...rea THIS AIR CONDITIONER IS MANUFACTURED BY ESTE ACONDICIONADOR DE AIRE HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQU PAR ESTE APARELHO DE AR CONDICIONADO FABRICADO POR QUESTO CONDIZIONATORE D ARIA...

Reviews: