background image

E-

Installation

Checkpoints prior to installation

 Check the cabinet and front grille of the unit for any harmful defects

such as scratches.

 Be sure to check the power supply.

- Refer to the specifications on the label attached to the unit.

Before installation, be sure to check the installation area or the air

conditioner, and drain hose.

Installation Conditions

 As the unit is heavy, the wall or window of the installation area should

have sufficient strength and durability for operation of the air conditioner,
and for prevention of any vibration or noise.
If it is weak, reinforcement work should be performed separately.

 It is advisable to install the air conditioner in the north or west side to

prevent the effect of direct sunlight.
When installing it in the south or east side due to unavoidable
circumstances, it is advisable to install the sunshade to prevent the
direct sunlight.
In this case, take care not to cause any hindrance to the flow of outside air.

3 When installing the air conditioner, be sure to obtain sufficient space on

the rear side of the unit for smooth flow of air.
When operating the air conditioner in closed areas such as inner building
with cooling operation, and result in trouble with the unit.
See the illustration below.

500mm

500mm

75mm

min.

300mm

500mm

150mm min.

"A"

Approx.3

750mm

45

45

  

The appliance must be fixed well by screw or similar

     method.

Awning

Fence, wall
or other
obstacle

          

  

If the wall is greater than 50mm thick,

                           cut the wall back on a 45° angle if possible.

Outdoor side

Indoor side

00mm or more

MODEL

“A”

AW07/AW09

45

AW

70

DB98-27204A.indd   11

2007-1-23   9:18:44

Summary of Contents for AW07P2 Series

Page 1: ...AW07P2 Series AW09P2 Series AW12P2 Series Window type Room Air Conditioner Cooling DB98 27204A USER S MANUAL E DB98 27204A indd 15 2007 1 23 9 18 46 ...

Page 2: ...st be plugged into its own specific power source which must be installed in compliance with national wiring earthing and safety regulations u If the power cord is damaged in any way it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard u This device must be installed according to the national electrical rules u The appliance must be...

Page 3: ...ommon Problems 10 INSTALLATION 11 Contents CAUTION The high inrush current of the starting compressor motor can have adverse effects to the operation of other equipment under unfavorable mains conditions This equipment does not comply with the relevant technical standards for the limitation of voltage fluctuations and flicker Before connection this equipment to the power supply system please repor...

Page 4: ...ow blades up down orientation Air inlet Outside Ventilation lever The design and shape are subject to change according to the model Power plug The type of the power plug may differ according to the type of local power supply Power Cable Operating mode selection dial Temperature control dial Air flow blade swing switch Fan speed switch DB98 27204A indd 4 2007 1 23 9 18 37 ...

Page 5: ...e air conditioner starts operating 2 To adjust the temperature turn the temperature control dial to the desired position Possible temperatures Between 18 C and 29 C inclusive Result The air conditioner starts cooling if the room temperature is higher than the selected temperature 3 Press the Fan Speed mode selector to the High or Low position Result The Fan speed is adjusted DB98 27204A indd 5 200...

Page 6: ...n Result The air simply circulates inside the room 2 To switch the unit on simply turn the Timer dial to Continue position Result The air conditioner starts operating 3 To airing your room only turn the temperature control dial to 1 position Result The air conditioner runs in fan mode 4 Press the Fan Speed mode selector to the High or Low position Result The Fan speed is adjusted Switching the Air...

Page 7: ...en the operating time reaches zero Adjusting the Air Flow Direction Horizontally Depending on the position of the unit in your room you can adjust the orientation of the inner air flow blades on the right hand side of the unit thus increasing the efficiency of the air conditioner 1 Set the air flow blade swing switch to the on position Result The inner blades swing automatically left and right 2 T...

Page 8: ...Drip from the blades Temperature and Humidity Ranges Mode IndoorTemperature OutdoorTemperature Indoor Humidity Cooling 21 C to 32 C approx 21 C to 43 C approx 80 or less The following table indicates the temperature and humidity ranges within which the air conditioner can be used in the best condition If the air conditioner is used at Then Higher temperatures The automatic protection feature may b...

Page 9: ...e order of disassembly 2 Pull the air filter to the right side 3 Remove all dust on the air filter with a vacuum cleaner or brush 4 When you have finished insert the air filter back into its original position 5 Wipe the surface of the unit with a neutral detergent and then wipe it again with dry cloth Be sure not to use benzene solvent or other chemical products If you Then Will not be using the a...

Page 10: ... temperature may be too low Dust may be blocking the air filter refer to page 8 cleaning instructions Check that there is no obstacle blocking the air flow into or out of the unit The air flow direction does not change when you set the air flow blade swing switch to the on position Check that the air conditioner has been switched on if necessary turn the operating mode selection dial refer to page...

Page 11: ...prevent the effect of direct sunlight When installing it in the south or east side due to unavoidable circumstances it is advisable to install the sunshade to prevent the direct sunlight In this case take care not to cause any hindrance to the flow of outside air 3 When installing the air conditioner be sure to obtain sufficient space on the rear side of the unit for smooth flow of air When operat...

Page 12: ...E 12 Rear Rubber cap Screws 2EA Gasket Drain Tube Installation Cont Installation of the Drain Tube Fix the drain tube as shown in the figure DB98 27204A indd 12 2007 1 23 9 18 44 ...

Page 13: ...E 13 Memo DB98 27204A indd 13 2007 1 23 9 18 44 ...

Page 14: ...DB98 27204A indd 14 2007 1 23 9 18 45 ...

Reviews: