Summary of Contents for AW0500

Page 1: ...AW0510 AW1510A AW05F05A AIR CONDITIONER CONTENTS 1 Precautions 2 Product Specifications 3 Installation and Operating Instructions 4 Disassembly and Reassembly 5 Troubleshooting 6 Exploded Views and Parts List 7 Block Diagram 8 Wiring Diagram SERVICE Manual ...

Page 2: ... cord and avoid tapping into a power cord This practice may result in malfunction or fire 6 After completing repairs and reassembly check the insulation resistance Procedure Prior to applying power measure the resistance between the power cord and the ground terminal The resistance must be greater than 30 megohms 7 Make sure that the grounds are adequate 8 Make sure that the installation condition...

Page 3: ...1 2 Samsung Electronics MEMO ...

Page 4: ...EON OZ kg BTU h Kcal h BTU h W Kcal hw LT h C F M LBS Row Type Row Type Model Model µF VAC µF VAC PSI 5 6 625 9 0 255 5 000 8 0 1 5 134 46 1 1 44A052HW1KA 4 30 370 4 8 515 12 0 340 5 100 9 7 1 5 125 46 2 2 44A052HS1KA 3 5 30 370 5 6 625 9 0 255 5 000 8 0 1 5 134 46 1 1 2R7S126A6F 4 35 270 4 8 515 12 0 340 5 100 9 7 1 5 125 46 2 2 2R7S126A6F 3 5 35 370 4 8 560 12 0 340 1 250 9 7 2 22 1 5 125 46 2 2...

Page 5: ...2 2 Samsung Electronics 2 2 Dimensions 314 3 4 5 452 Unit mm ...

Page 6: ...e 5 Make sure that you install the unit in an area away from TVs audio units cordless phones fluorescent lighting fixtures and other electrical appliances at least 1 meter clearance 6 Make sure that you install the unit in an area which provides easy drainage for condensed water 7 Make sure that you install the unit in area not exposed to the rain or direct sunlight Install a separate sunblind if ...

Page 7: ...Cool air will be ceased below 7 13 C Slowly turn the Fan Selector Switch in the following order to LOW FAN HIGH FAN HIGH COOL MED COOL LOW COOL OFF All functions will be off LOW FAN The circulation of air is low HIGH FAN The circulation of air is maximum LOW COOL Circulation cooling and humidity removal are low all simultaneousy operated MED COOL Circulation cooling and humidity removal are medium...

Page 8: ...d lines Replace compressor Inspect electrical wiring for defects and terminals for correct and secure connections Solder discharge line Corrective action Check refrigerant oil level Add oil as necessary Solder suction line Use nitrogen gas Perform soldering function Fillsystemwithnitrogengas Check for leakage Pinch and braze filling tube Recharge system Evacuate system Release nitrogen gas Problem...

Page 9: ... leak generally it is not necessary to add oil unless the oil has leaked significantly Put approximately 10cc oil into a transparent container and test it 4 3 Refrigerant Oil Specifications Normal Overheat Motor Damage Condition of Refrigerant Cycle Color Light Yellow Brown Color Dark Brown No Odor Pungent Oil Odor Remarks Return with the system Oil Change Oil Change Condition of Oil Model Oil Spe...

Page 10: ...ehind the guard air filter 2 Remove the grille from the cabinet by pushing in on the grille tabs on both cabinet sides and then lift the grille off the top latches Ass y Frame 1 Remove the 7 screws on each of the cabinet and lift the cabinet upward Ass y Evaporator 1 Remove foam seal on the top of the unit 2 Remove 4 screw on the both side of evaporator 3 Separate the evaporator from the unit Ass ...

Page 11: ... of condenser 2 Separate the cond casing from the base pan 3 Loose the nut to disassemble the fan propeller 4 Separate the fan propeller from the motor and the cond casing Ass y Control 1 Remove the 2 screws at the bottom of between the base pan and the control box 2 Separate the power cord from the base pan Ass y Motor 1 Remove the 2 screws on the motor and mountor motor 2 Separate the motor from...

Page 12: ...switch 2 switch is faulty 2 check the motor 3 motor is faulty 1 check the refrigerant leakage 1 Caused by the pipe crack 2 check the evaporator condition 2 shortage of refrigerant freezing blocked with dusts etc 3 clean the evaporator air filter Difference of temp exists between the suction side and the discharge side at least 12 C Standard condition Indoor 27 C outdoor 35 C 1 check vibration of t...

Page 13: ...1 Samsung Electronics 6 Exploded View and Parts List 34 35 37 36 1 3 1 2 3 4 5 7 8 21 41 40 22 23 38 27 28 29 30 31 32 25 26 33 33 1 33 2 33 3 33 4 33 5 33 6 24 9 10 11 12 14 15 16 39 20 17 18 19 13 6 3 2 ...

Page 14: ...OVER PARTITION ASSY CONTROL BOX ASSY CONTROL BOX ASSY CONTROL ASSY CONTROL ASSY CONTROL BOX PLATE CONTROL SWITCH ROTARY THERMOSTAT C OIL C OIL C OIL C OIL CLIP CAPACITOR POWER CORD CABINET OK SHUTTER ANGLE UP SHUTTER ANGLE UP ASSY SHUTTER RH ASSY SHUTTER RH ASSY SHUTTER LF ASSY SHUTTER LF ASSY COMP ASSY COMP ASSY COMPRESSOR ASSY SCREW DRAIN PLUG DRAIN TUBE RUBBER DRAIN RUNNER DRAIN ABS SC 94445R A...

Page 15: ...6 3 Samsung Electronics MEMO ...

Page 16: ... 7 1 7 Block Diagram 7 1 Refrigerating Cycle Block Diagram PINCH PIPE SERVICE VALVE PINCH PIPE SERVICE VALVE SUCTION LINE ACCUMULATOR COMPRESSOR EVAPORATOR CAPILLARY TUBE CONDENSER DISCHARGE LINE PINCH PIPE SERVICE VALVE ...

Page 17: ...7 2 Samsung Electronics MEMO ...

Page 18: ...UTRAL RIB ACTIVE WHT L C S R C THERMOSTAT BLK H S 2 3 SELECTOR SWITCH 8 Wiring Diagram DIAGRAM ELECTRIC AW05B05A AW0500 AW05E05A AW0510 AW05B05A AW0500A AW05E05A AW0510A AW05F05A CAPACITOR 4 30µF 370VAC CAPACITOR 3 5 30µF 370VAC CAPACITOR 4 35µF 270VAC CAPACITOR 3 5 35µF 370VAC CAPACITOR 3 5 30µF 370VAC ...

Page 19: ...8 2 Samsung Electronics MEMO ...

Page 20: ...ay not in whole or in part be copied photocopied reproduced translated or converted to any electronic or machine readable from without prior written permission of Samsung Electronics Co Ltd SyncMaster 17GLi CMG7387L Service Manual First edition June 1995 Printed in Korea Trademarks Samsung is a registered trademark and SyncMaster 17GLi CMG7387L and MacMaster Cable Adapter are trademark of Samsung ...

Page 21: ...Samsung Electronics Co Ltd May 2000 Printed in Korea Code No DB81 00118A 3 ELECTRONICS ...