Summary of Contents for AVMCC052CA1

Page 1: ...stema Ar Condicionado Klimaanlage System ÛÙËÌ ÏÈÌ ÙÈÛÌÔ ëËÒÚÂÏÌ È ÇÓÁ Û Ì È äÓÌ ËˆËÓÌ ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA RUSSIAN E S F I P D G R DB98 13707A 3 AVMCH052CA1 4 AVMCH072CA1 4 AVMCH105CA1 4 AVMCH128CA1 4 AVMCH140CA1 4 AVMCH052EA B 1 4 AVMCH070EA B 1 4 AVMCH105EA B 1 4 AVMCH128EA B 1 4 AVMCH140EA B 1 4 Heat pump AVMCC052CA1 4 AVMCC072CA1 4 AVMCC105CA1 4 AVMCC128CA1 4 AV...

Page 2: ... the Unit 9 Connecting the Refrigerant Pipe 10 Cutting Flaring the Pipes 11 Performing Leak Test Insulation 12 Drainpipe and Drain Hose Installation 13 Connecting the Connection Cord 15 Assigning Address to Indoor Unit 16 Additional Functions 17 Bio pure Filter Installation Optional 18 Troubleshooting 19 4 4 4 4 W W W WA A A AY Y Y Y C C C CA A A AS S S SS S S SE E E ET T T TT T T TE E E E I I I I...

Page 3: ... Test Insulation 12 Drainpipe and Drain Hose Installation 13 Connecting the Connection Cord 15 Assigning Address to Indoor Unit 16 Additional Functions 17 Bio pure Filter Installation Optional 18 Troubleshooting 19 4 4 4 4 W W W WA A A AY Y Y Y C C C CA A A AS S S SS S S SE E E ET T T TT T T TE E E E I I I IN N N NS S S ST T T TA A A AL L L LL L L LA A A AT T T TI I I IO O O ON N N N Chapter E 3 E...

Page 4: ...Saline air Machine oil Sulphide gas Special environmental conditions If you must install the unit in such conditions first consult your dealer Accessories The following accessories are supplied with the indoor unit The type and quantity may differ depending on the specifications E 4 Pattern sheet Insulation Insulation cover drain Insulation cover band Insulation pipe Insulation drain hose Installa...

Page 5: ...it on a ceiling that can support its weight Maintain sufficient clearance around the indoor unit Make sure that the water dripping from the drain hose runs away correctly and safely The indoor unit must be installed in this way that they are out of public access Not touchable by the users E 5 ENGLISH Space Requirements for Indoor Unit ...

Page 6: ...0 M4 Hole prepared hole Fresh air intake hole 55 246 230 100 80 55 290 2x230 260 25 20 25 198 293 256 318 111 141 1 2 3 4 5 6 Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection Air discharge grille Air suction grille ø9 52 ø15 88 No Name Remark Drawing of the indoor unit 052 070 072 Unit mm ...

Page 7: ...55 840 55 25 25 20 198 158 138 304 288 68 290 2x230 260 10 M4 Hole prepared hole Branch duct connection OPEN CLOSED OPEN CLOSED 1 2 3 4 5 6 Liquid pipe connection Gas pipe connection Drain pipe connection Power supply connection Air discharge grille Air suction grille ø9 52 ø19 05 No Name Remark 105 128 140 Unit mm ...

Page 8: ...ust a space between the ceiling and the indoor unit by using the gauge of dimensions 7 3 Fix the indoor unit securely after adjusting level of the unit by using a leveler 7 4 Remove the pattern sheet connect the other cables and install the front panel Ensure that the ceiling is strong enough to support the weight of the indoor unit Before hanging the unit test the strength of each attached suspen...

Page 9: ...onnect the piping N N N No o o ot t t te e e e On delivery the indoor unit is loaded with refrigerant gas All this gas must therefore be purged before connecting the assembly piping To purge the inert gas proceed as follows Unscrew the pinch pipe at the end of each refrigerant pipe Result All inert gas escapes from the indoor unit Liquid refrigerant port Gas refrigerant port ...

Page 10: ...e to protect the condensate water on the outside of pipe falling onto the floor and the efficiency of the unit will be better 2 Cut off any excess foam insulation 3 Be sure that there must be no crack or wave on the bended area 4 It would be necessary to double the insulation thickness 10mm or more to prevent condensation even on the insulator when if the installed area is warm and humid 5 If the ...

Page 11: ...correctly 2 To prevent any gas from leaking out remove all burrs at the cut edge of the pipe using a reamer 3 Slide a flare nut on to the pipe and modify the flare 4 Check that the flaring is correct referring to the illustrations below for examples of incorrect flaring 5 Align the pipes and tighten the flare nuts first manually and then with a torque wrench applying the following torque 6 Outer D...

Page 12: ...Acrylonitrile Butadien Rubber around each refrigerant pipe 1 Wind insulating tape around the pipes and drain hose 2 Finish wrapping insulating tape around the rest of the pipes leading to the outdoor unit 3 Always make the seam of pipes face upwards N N N No o o ot t t te e e e Leak Test Insulation Insulation cover pipe Be sure to overlap the insulation Indoor Unit Insulation pipe C C C CA A A AU ...

Page 13: ...necessary to increase the height of the drainpipe install the drainpipe straightly within 300 mm from the flexible hose port If it is raised higher than 550 mm there can be water leaks Care must be taken when installing the drainpipe and drain hose for the indoor unit so that condensate water is drained correctly outside Fix the flexible hose to the drainpipe The connection port of the flexible ho...

Page 14: ... hose 3 Reassemble the cover drain pump 4 You can check the drainage only when the air conditioner is in cool mode N N N No o o ot t t te e e e If you do not pour water inside the water supply intake water may spill from the indoor unit N N N No o o ot t t te e e e Testing the drainage Cover drain pump If a concentrated drain hose is installed refer to the figure below N N N No o o ot t t te e e e...

Page 15: ...cord Remove the screw on the electrical component box and remove the cover plate 1 Route the connection cord through the side of the indoor unit and connect the cable to terminals refer to the figure below 2 Route the other end of the cable to the outdoor unit through the ceiling the hole on the wall 3 Reassemble the electrical component box cover carefully tightening the screw 4 Next Indoor unit ...

Page 16: ...AIN address from 00 to 39 by mixing SW01 and SW02 The MAIN address from 00 to 39 should differ from each other Check the indoor unit address on the plan that you are to install and set the address according to the plan Setting RMC Address The SW03 RMC switch is the address setting switch for controlling the indoor unit with the wired remote controller and centralized controller You must set the SW...

Page 17: ...witch ON Switch OFF K5 5 C compensation 2 C compensation Switch No Switch ON Switch OFF K1 K2 K3 K4 SW04 K5 K6 K7 K8 Adjusting filter cleaning cycle You can adjust the cycle for filter sign indicator K6 1000 hours 2000 hours Switch No Switch ON Switch OFF K5 K6 K7 K8 Control of electronic expansion valve at the indoor unit off When an indoor unit off makes refrigerant noise set K9 to OFF position ...

Page 18: ...tall the filter and the front grille 7 Do not remove the packing from a bio pure filter until you wish to use the filter as it will lose its properties N N N No o o ot t t te e e e The air conditioner can be fitted with a Bio Pure filter to remove minute dust particles The service life of the filter is approximately three months depending on the time during which the air conditioner is used Remove...

Page 19: ...unit Error of outlet temperature sensor in indoor unit OPEN SHORT For heat pump models only Error of mixed operation Error of outdoor temperature sensor Error of COND sensor Error of DISCHARGE sensor 1 No communication for 2 minutes between indoor unit and outdoor unit communication error for more than 2 minutes 2 Indoor unit receiving the communication error from outdoor unit 3 Outdoor unit track...

Page 20: ...rror of electronic expansion valve open 3 Breakaway of EVA OUT sensor 4 Breakaway of EVA IN sensor 5 Breakaway of COND MID sensor 6 2nd detection of refrigerant completely leak 7 2nd detection of high temperature COND 8 2nd detection of high temperature DISCHARGE 9 COMP DOWN due to 2nd detection of low pressure switch 10 Error of reverse phase 11 Compressor down due to 6th detection of freezing 12...

Page 21: ...or unit OPEN SHORT error of eva in sensor in indoor unit OPEN SHORT error of eva out sensor in indoor unit EEPROM error EEPROM option error Error of fan starting Error of outdoor unit Communication errors Displays related to indoor unit x 0 F For the details refer to the installation manual of the outdoor unit Remark The order of priority EA Eb Cx dx bx Ax Fx ox qx rx sx tx Ux vx Eo In case that t...

Page 22: ... Parts List 23 O O O OP P P PT T T TI I I IO O O ON N N NA A A AL L L L A A A AC C C CC C C CE E E ES S S SS S S SO O O OR R R RI I I IE E E ES S S S Chapter E 22 ...

Page 23: ...power cable 1 Transmitter communicationcable 1 Transmitter Accessories Owner s instructions 1 Installation manual 1 Owner s instructions 1 Installation manual 1 Installation manual 1 Function controller 1 Cable tie 2 Cable clamp 6 M4x16 tapped screw 7 Function Controller Accessories Owner s instructions 1 Installation manual 1 Wireless remote controller 1 Battery 2 Remote control holder 1 STS 2S 2...

Page 24: ...ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR QUESTO CONDIZIONATORE D ARIA È PRODOTTO DA ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR DIESE KLIMAANLAGE IST FABRIZIERT VON AYTH H Y KEYH KATA KEYA THKE A O ùíéí äéçÑàñàéçÖê àáÉéíéÇãÖç îàêåéâ ...