Samsung Electronics
5-9
Troubleshooting
5-4 Fault Diagnosis of Major Parts
Parts
Temp.Sensor
Heat ex. Sensor
Indoor Fan Motor
Outdoor Fan Motor
Stepping Motor
(UP/DOWN swing motor)
Diagnosis
Measure resistance with a tester.
Normal
8K
Ω
~27K
Ω
at ambient temperature (+0°C ~ +30°C)
Abnormal
∞
, O
Ω
… open or short
Measure resistance between terminals (CN72) with a tester
Normal
At ambient temperature (10°C ~ 30°C)
Abnormal
Measure the voltage between ground and signal wire of the fan motor
Normal
Abnormal
Abnormal if voltage does not change from 0V to 5V.
Normal
At ambient temperature (10°C ~ 30°C)
Abnormal
∞
, O
Ω
… open or short
Measure resistance between red wire and each terminal.
Normal
Approx. 380
Ω
at ambient temperature (20°C ~30°C)
Abnormal
∞
, O
Ω
… open or short
Between
Resistance
Yellow, Blu
190 ±10
Ω
Yellow, Red
240±15
Ω
Between
Voltage
Gray, Orange
05V~4.5V
Yellow, Orange
5V
between
Resistance
Black, Yellow
189±10
Ω
Black, Red
220±10
Ω
Summary of Contents for AS-2408BR
Page 2: ... Samsung Electronics Co Ltd FEB 1999 Printed in Korea Code No DB81 10161A 3 ...
Page 4: ...1 2 Samsung Electronics MEMO ...
Page 20: ...3 14 Samsung Electronics MEMO ...
Page 34: ...Samsung Electronics 6 1 6 Exploded Views and Parts List 6 1 Indoor Unit ...
Page 40: ...6 7 Samsung Electronics MEMO ...
Page 41: ...Samsung Electronics 6 1 6 Exploded Views and Parts List 6 1 Indoor Unit ...
Page 47: ...6 7 Samsung Electronics MEMO ...
Page 50: ...Samsung Electronics 7 3 MEMO ...
Page 54: ...Samsung Electronics 10 1 10 Schematic Diagrams 10 1 Indoor Unit ...
Page 55: ...Samsung Electronics 10 2 10 2 Remote Control ...