49
No.
Parts
Procedure
Remark
10
Bracket Motor 1) Remove the 2 screws from
the Bracket Motor and separate
it. (Use +Screw Driver)
11
Control Out
1) Disconnect 6 Connecters
From Ass’y Control Out.
2) Unscrew and remove 4
mounting screw on Control Out.
(Use +Screw Driver)
3) Separate Ass’y Control Out.
12
4 Way Valve
1) First, discharge the
refrigerant.
2) Remove the 2 screws which
is fixed to Service Valve and
separate it. (Use
+Screw Driver)
3) Separate the inlet and outlet
pipes by welding torch.
!CAUTION : If you separate the
Compressor, Heat Exchanger
or Pipe, please fully discharge
refrigerant in the Compressor
and then separate the Pipe by
welding torch.