Samsung Electronics
8-3
8-2 Connecting Up and Purging the Circuit
p
hT
p
iT
}
w
z
}
z
WARNING
When installing, make sure there is no leakage. When recovering the refrigerant, ground
ƚŚĞĐŽŵƉƌĞƐƐŽƌĮƌƐƚďĞĨŽƌĞƌĞŵŽǀŝŶŐƚŚĞĐŽŶŶĞĐƟŽŶƉŝƉĞ͘/ĨƚŚĞƌĞĨƌŝŐĞƌĂŶƚƉŝƉĞŝƐŶŽƚƉƌŽƉĞƌůLJ
connected and the compressor works with the service valve open, the pipe inhales the air and
ŝƚŵĂŬĞƐƚŚĞƉƌĞƐƐƵƌĞŝŶƐŝĚĞŽĨƚŚĞƌĞĨƌŝŐĞƌĂŶƚĐLJĐůĞĂďŶŽƌŵĂůůLJŚŝŐŚ͘/ƚŵĂLJĐĂƵƐĞĞdžƉůŽƐŝŽŶĂŶĚŝŶũƵƌLJ͘
dŚĞŽƵƚĚŽŽƌƵŶŝƚŝƐůŽĂĚĞĚǁŝƚŚƐƵĸĐŝĞŶƚZͲϰϭϬƌĞĨƌŝŐĞƌĂŶƚ͘
ŽŶŽƚǀĞŶƚZͲϰϭϬŝŶƚŽĂƚŵŽƐƉŚĞƌĞ͗ŝƚŝƐĂŇƵŽƌŝŶĂƚĞĚŐƌĞĞŶŚŽƵƐĞŐĂƐ͕
ĐŽǀĞƌĞĚďLJ<LJŽƚŽWƌŽƚŽĐŽů͕ǁŝƚŚĂ'ůŽďĂůtĂƌŵŝŶŐWŽƚĞŶƟĂů;'tWͿсϮϬϴϴ͘
You should purge the air in the indoor unit and in the pipe.
/ĨĂŝƌƌĞŵĂŝŶƐŝŶƚŚĞƌĞĨƌŝŐĞƌĂŶƚƉŝƉĞƐ͕ŝƚĂīĞĐƚƐƚŚĞĐŽŵƉƌĞƐƐŽƌ͘
/ƚŵĂLJĐĂƵƐĞƌĞĚƵĐƟŽŶŽĨĐŽŽůŝŶŐĐĂƉĂĐŝƚLJĂŶĚŵĂůĨƵŶĐƟŽŶ͘
Refrigerant for air purging is not charged in the outdoor unit.
hƐĞsĂĐƵƵŵWƵŵƉĂƐƐĞĞŶŝŶƚŚĞƉŝĐƚƵƌĞ͘
ϭ͘ŚĞĐŬƚŚĞƉŝƉŝŶŐĐŽŶŶĞĐƟŽŶƐ͘
Ϯ͘ŽŶŶĞĐƚƚŚĞĐŚĂƌŐŝŶŐŚŽƐĞŽĨůŽǁƉƌĞƐƐƵƌĞƐŝĚĞŽĨŵĂŶŝĨŽůĚŐĂƵŐĞ
to the packed valve having a service port .
hd/KE
DĂŬĞƚŚĞĞůĞĐƚƌŝĐĂůĐŽŶŶĞĐƟŽŶĂŶĚůĞĂǀĞƚŚĞƐLJƐƚĞŵŝŶƚŽ͞ƐƚĂŶĚďLJŵŽĚĞ͘͟
ŽŶŽƚƚƵƌŶŽŶƚŚĞƐLJƐƚĞŵ͊dŚŝƐŝƐŶĞĐĞƐƐĂƌLJĨŽƌďĞƩĞƌǀĂĐƵƵŵŽƉĞƌĂƟŽŶ
;ĨƵůůKWEƉŽƐŝƟŽŶŽĨůĞĐƚƌŽŶŝĐdžƉĂŶƐŝŽŶsĂůǀĞͲsͲͿ͘
ϯ͘KƉĞŶƚŚĞǀĂůǀĞŽĨƚŚĞůŽǁƉƌĞƐƐƵƌĞƐŝĚĞŽĨŵĂŶŝĨŽůĚŐĂƵŐĞ
counter clockwise.
ϰ͘WƵƌŐĞƚŚĞĂŝƌĨƌŽŵƚŚĞƐLJƐƚĞŵƵƐŝŶŐǀĂĐƵƵŵƉƵŵƉĨŽƌĂďŽƵƚϯϬŵŝŶƵƚĞƐ͘
ϱ͘ůŽƐĞƚŚĞǀĂůǀĞŽĨƚŚĞůŽǁƉƌĞƐƐƵƌĞƐŝĚĞŽĨŵĂŶŝĨŽůĚŐĂƵŐĞĐůŽĐŬǁŝƐĞ͘
ϲ͘DĂŬĞƐƵƌĞƚŚĂƚƉƌĞƐƐƵƌĞŐĂƵŐĞƐŚŽǁͲϬ͘ϭDWĂ;ͲϳϲĐŵ,ŐͿĂŌĞƌĂďŽƵƚ
ϯϬŵŝŶƵƚĞƐ͘dŚŝƐƉƌŽĐĞĚƵƌĞŝƐǀĞƌLJŝŵƉŽƌƚĂŶƚŝŶŽƌĚĞƌƚŽĂǀŽŝĚŐĂƐůĞĂŬ͘
ϳ͘dƵƌŶŽīƚŚĞǀĂĐƵƵŵƉƵŵƉ͘
ϴ͘ZĞŵŽǀĞƚŚĞŚŽƐĞŽĨƚŚĞůŽǁƉƌĞƐƐƵƌĞƐŝĚĞŽĨŵĂŶŝĨŽůĚŐĂƵŐĞ͘
ϵ͘^ĞƚǀĂůǀĞĐŽƌŬŽĨďŽƚŚůŝƋƵŝĚƐŝĚĞĂŶĚŐĂƐƐŝĚĞŽĨƉĂĐŬĞĚǀĂůǀĞ
ƚŽƚŚĞŽƉĞŶƉŽƐŝƟŽŶ͘
ϭϬ͘DŽƵŶƚƚŚĞǀĂůǀĞƐƚĞŵŶƵƚƐĂŶĚƚŚĞƐĞƌǀŝĐĞƉŽƌƚĐĂƉƚŽƚŚĞǀĂůǀĞ͕
ĂŶĚƟŐŚƚĞŶƚŚĞŵĂƚƚŚĞƚŽƌƋƵĞŽĨϭϴϯŬŐĨͻĐŵǁŝƚŚĂƚŽƌƋƵĞǁƌĞŶĐŚ͘
A
B
C
D
Valve stem
^ƚĞŵĂƉ
Service port
Valve stem
^ƚĞŵĂƉ
Service port
}
w
}
w
Model Name
:ϬϰϬD:Ϯ,
Valve
ϯͬϴ͟
ϭͬϮ͟
Ϯ
Ͳ
:ϬϱϬD:Ϯ,
ϭ
ϭ
:ϬϲϴD:ϯ,
Ϯ
ϭ
:ϬϳϬͬϬϴϬD:ϰ,
Ϯ
Ϯ
:ϭϬϬD:ϱ,
Ϯ
3
Summary of Contents for AR09/12JSPFBWKN
Page 49: ...Samsung Electronics 3 13 AJ100MCJ5EH EU...
Page 56: ...3 20 Samsung Electronics MEMO...
Page 70: ...Samsung Electronics 4 17...
Page 71: ...4 18 Samsung Electronics...
Page 89: ...4 36 Samsung Electronics T m k z T TXGGp...
Page 90: ...Samsung Electronics 4 37...
Page 91: ...4 38 Samsung Electronics 4 6 1 3 Communica n error a er g Tracking...
Page 95: ...4 42 Samsung Electronics 4 6 4 Outdoor unit fan error...
Page 99: ...4 46 Samsung Electronics 4 6 7 2 Outdoor out cond temperature sensor error...
Page 107: ...Samsung Electronics 5 7 6 Remocon signal out 9 Remocon signal IN CN01 DISPLAY Panel PCB 1...
Page 116: ...Samsung Electronics 6 1 6 Wiring Diagram 6 1 INDOOR UNIT AR SP AR SW DB68 04014A 9...
Page 117: ...6 2 Samsung Electronics AR FPE AR FHB DB68 05092A 3...
Page 118: ...Samsung Electronics 6 3 to mzlh k z N U...
Page 120: ...6 5 Samsung Electronics k z N U uqWY so lhVuqWZ so lh...
Page 121: ...Samsung Electronics 6 6 k z N U toW Ym lh...
Page 122: ...6 7 Samsung Electronics to mqlh k z N U...
Page 123: ...6 8 Samsung Electronics 6 2 OUTDOOR UNIT k z N U hqW WtjqYloVl GVGhqW WtjqYloVl...
Page 125: ...Samsung Electronics 6 10 AJ100MCJ5EH EU...
Page 128: ...7 3 Samsung Electronics to mzlh k z N U...
Page 130: ...Samsung Electronics 7 5 to mqlh k z N U...
Page 131: ...7 6 Samsung Electronics uq so lhVto m lh k z N U...
Page 135: ...Samsung Electronics 7 10 AJ100MCJ5EH EU PCB MAIN...
Page 136: ...Samsung Electronics 7 11 AJ100MCJ5EH EU PCB MAIN...
Page 137: ...Samsung Electronics 7 12 AJ100MCJ5EH EU PCB INVERTER...
Page 138: ...Samsung Electronics 7 13 AJ100MCJ5EH EU PCB HUB...
Page 151: ...Samsung Electronics 8 15 AJ100MCJ5EH EU AJ070 080MCJ4EH EU...