Samsung AR**KSFP** series User Manual Download Page 14

13

English

A

t a Glanc

e

Remote Control Overview

01 

Set temperature indicator

02 

Timer option indicator

03 

Operation mode indicator

04 

Options indicator

05 

Low battery indicator

06 

Transmit indicator

07 

Fan speed indicator

08 

Vertical air swing indicator

09 

Horizontal air swing indicator (Without this 
function)

10 

Settings indicator

11 

Power button

12 

Temperature button

13 

Options button

14 

Timer button

15 

Direction button / Selection button

16 

Vertical air swing button

17 

Mode button

18 

Fan speed button

19 

Horizontal air swing button(Without this 
function)

20 

Settings button

21 

SET button

  NOTE

ŷ

The descriptions in this manual are primarily 
made based on the remote control buttons.

ŷ

Although 

Virus Doctor(

)

/

d'light Cool /

Usage / Filter Reset / Display / Horizontal 
air swing indicator 

is displayed on the 

remote control display, it is not available on 
this model. 

01

05

06

07

08

10

09

16

17

18

20

21

02

03

04

11

12

13

19

14

15

Inserting batteries

two 1.5V AAA type batteries

Summary of Contents for AR**KSFP** series

Page 1: ...VISIT US ONLINE AT U S A Consumer Electronics Mobile Phones 1 800 SAMSUNG 726 7864 HHP 1 844 SAM PAYS 726 7297 www samsung com us support CANADA 1 800 SAMSUNG 726 7864 www samsung com ca support English www samsung com ca_fr support French ...

Page 2: ...Air conditioner User manual AR77KSFP77 ŷ Thank you for purchasing this Samsung air conditioner ŷ Before operating this unit please read this user manual carefully and retain it for future reference ...

Page 3: ...eatures 16 Cooling Operation 16 RRO PRGH ŷ 6WHS FRROLQJ IXQFWLRQ Dehumidifying Operation 17 Dry mode Air Purifying Operation 17 Virus doctor function Heating Operation 18 Heat mode Quick Smart Features 19 XWR PRGH ŷ DQ PRGH ŷ DVW IXQFWLRQ ŷ RPIRUW IXQFWLRQ ŷ HHS VRXQG IXQFWLRQ ŷ 4XLHW IXQFWLRQ ŷ Energy Saving Features 22 Energy Saving Operation 23 6LQJOH XVHU IXQFWLRQ ŷ 7LPHG RQ 7LPHG RII IXQFWLRQ...

Page 4: ...Changing the direction of the drain hose Step 2 6 Installing and connecting the assembly pipes to the refrigerant pipes assembly pipe Step 2 7 Shortening or extending the refrigerant pipes assembly pipe Step 2 8 Fixing the installation plate Outdoor Unit Installation 44 Step 3 1 Fixing the outdoor unit in place Step 3 2 Connecting the power and communication cables and the refrigerant pipes Step 3...

Page 5: ...w appliance Because the following operating instructions cover various models the characteristics of your air conditioner may differ slightly from those described in this manual If you have any questions call your nearest contact centre or find help and information online at www samsung com WARNING Hazards or unsafe practices that may result in severe personal injury or death CAUTION Hazards or un...

Page 6: ...nstalled product Install an Isolation Switch next to the Air Conditioner but not on the panels of the Air Conditioner and circuit breaker dedicated to the air conditioner ŷ Failing to do so may result in electric shock or fire Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed ŷ Failing to do so may result in electric shock fire explosion or problems with the ...

Page 7: ...ght ŷ Failing to do so may result in abnormal vibrations noise or problems with the product Install the drain hose properly so that water drains correctly ŷ Failing to do so may result in water overflowing and property damage Avoid adding drain to waste pipes as odours may arise in the future When installing the outdoor unit make sure to connect the drain hose so that draining is performed correct...

Page 8: ...Failing to do so may result in electric shock or fire FOR USING WARNING If the appliance is flooded please contact your nearest service centre ŷ Failing to do so may result in electric shock or fire If the appliance generates a strange noise a burning smell or smoke cut off the power supply immediately and contact the nearest service centre ŷ Failing to do so may result in electric shock or fire I...

Page 9: ...t turn the air conditioner off with the circuit breaker while it is operating ŷ Turning the air conditioner off and then on again with the circuit breaker may cause a spark and result in electric shock or fire After unpacking the air conditioner keep all packaging materials well out of the reach of children as packaging materials can be dangerous to children ŷ If a child places a bag over its head...

Page 10: ...y and contact the nearest service centre ŷ Failing to do so may result in electric shock or fire Do not attempt to repair disassemble or modify the appliance yourself ŷ Do not use any fuse such as cooper steel wire etc other than the standard fuse ŷ Failing to do so may result in electric shock fire problems with the product or injury CAUTION Do not place objects or devices under the indoor unit ŷ...

Page 11: ...t drink the water from the air conditioner ŷ The water may be harmful to humans Do not apply a strong impact to the remote control and do not disassemble the remote control Do not touch the pipes connected with the product ŷ This may result in burns or injury Do not use this air conditioner to preserve precision equipment food animals plants or cosmetics or for any other unusual purposes ŷ This ma...

Page 12: ...Before cleaning or performing maintenance cut off the power supply and wait until the fan stops ŷ Failing to do so may result in electric shock or fire CAUTION Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges ŷ This should be done by a qualified technician Please contact your installer or service centre Do not clean the inside of the air condit...

Page 13: ...07 05 01 Air intake 02 Air filter 03 Air flow blade up and down 04 Air flow blade left and right 05 Room temperature sensor 06 Display 07 Power button Remote control receiver Display 01 02 03 04 05 01 good sleep indicator 02 Timer indicator Auto clean indicator 03 Operation indicator 04 Power button 05 Remote controller receiver ...

Page 14: ...tton 14 Timer button 15 Direction button Selection button 16 Vertical air swing button 17 Mode button 18 Fan speed button 19 Horizontal air swing button Without this function 20 Settings button 21 SET button NOTE ŷ The descriptions in this manual are primarily made based on the remote control buttons ŷ Although Virus Doctor d light Cool Usage Filter Reset Display Horizontal air swing indicator is ...

Page 15: ...e Cool Dry Heat Indoor temperature 61 F to 90 F 16 C to 32 C 65 F to 90 F 18 C to 32 C 81 F 27 C or less Outdoor temperature 14 F to 114 F 10 C to 46 C 14 F to 114 F 10 C to 46 C 5 F to 75 F 15 C to 24 C Indoor humidity 80 or less relative humidity _ _ ŷ If the air conditioner operates in a high humidity environment in the Cool mode for an extended period of time condensation may occur ŷ If the ou...

Page 16: ...t the vertical air flow blade manually it may not close completely when you turn off the air conditioner ŷ You can control the vertical air flow direction when the good sleep function is running while in the Heat mode but not while in the Cool mode Horizontal air flow manual Keep the horizontal air flow in a constant direction by changing the directions of the horizontal air flow blades manually C...

Page 17: ...elect a function temperature and fan speed that you want to apply To cool your room quickly select a low temperature and a strong fan speed To save energy select a high temperature and a weak fan speed As the indoor temperature approaches the set temperature the compressor will operate at a low speed to save energy 2 Step cooling function Use the 2 Step cooling function to quickly reach the set te...

Page 18: ...Operation Dry mode Use the Dry mode in rainy or humid weather Ź Ź Select Dry NOTE ŷ The lower the set temperature is the greater the dehumidifying capacity is When the current humidity seems to be high adjust the set temperature to a low temperature ŷ You cannot use the Dry mode for heating The Dry mode is designed to produce a cooling side effect ...

Page 19: ...ade to the lowest position as shown in the left figure to prevent cold air from coming out from the indoor unit A The position of the vertical air flow blade when the defrost function is running The blade looks almost closed B The position range of the vertical air flow blade when the Heat mode is running ŷ When the defrost function is running no air comes out from the indoor unit in order to prev...

Page 20: ...warm air to warm up the indoor temperature Fan mode Use the Fan mode to run the air conditioner like a common fan The air conditioner provides a natural breeze Ź Ź Select Fan NOTE ŷ If the air conditioner will not be used for an extended period of time dry the air conditioner by running it in the Fan mode for 3 or 4 hours ŷ The outdoor unit is designed not to operate in the Fan mode to prevent col...

Page 21: ...hen you select the Fast function in the Heat mode you may not be able to increase the fan speed in order to prevent cool air from blowing Comfort function Use the Comfort function when you feel the current cooling or heating effect is too strong The air conditioner provides a mild cooling or heating You can select this function both in the Cool and Heat modes In the Cool or Heat mode Ź Ź Ź Select ...

Page 22: ...the Quiet function to reduce operating noise You can select this function both in the Cool and Heat modes In the Cool or Heat mode Ź Ź Ź Select Quiet Ź NOTE ŷ You can change the set temperature and the air flow direction ŷ You cannot change the fan speed ŷ If you select the Quiet function while such functions as 2 Step cooling Fast Comfort Single user or good sleep are running these functions are ...

Page 23: ...t or good sleep are running these modes are cancelled ŷ After selecting the Single user function you can change the set temperature 76 F to 86 F 24 C to 30 C in the Cool mode 61 F to 86 F 16 C to 30 C in the Heat mode fan speed and vertical air flow direction ŷ When the Single user function is turned on in the Cool mode while the set temperature is set to lower than 76 F 24 C the set temperature i...

Page 24: ... is displayed on the indoor unit display ŷ After starting the Timed on function you can change the mode and the set temperature You cannot change the set temperature while the Fan mode is running ŷ You cannot set the same time for both of the Timed on and Timed off functions Combining Timed on and Timed off When the air conditioner is off Example Timed on 3 hours Timed off 5 hours The air conditio...

Page 25: ...rature Optimal set temperature Cool 77 F to 81 F 25 C to 27 C 79 F 26 C Heat 70 F to 73 F 21 C to 23 C 72 F 22 C ŷ 2QFH RX VWDUW WKH JRRGŰVOHHS IXQFWLRQ WKH 7LPHU indicator appears on the indoor unit display ŷ You can set the operation time to between 0 5 and 12 hours Set the operation time to 0 0 to cancel the JRRGŰVOHHS IXQFWLRQ ŷ 7KH GHIDXOW RSHUDWLRQ WLPH IRU WKH JRRGŰVOHHS IXQFWLRQ LQ the Coo...

Page 26: ...nditioner is on Auto clean starts as soon as the air conditioner stops running ŷ During Auto clean the indoor fan continues to run and air flow blades remain open to expel ambient air Cleaning the indoor unit exterior and outdoor unit heat exterior CAUTION ŷ Do not clean the display by using alkaline detergent Cleaning at a Glance Cleaning duration minutes Auto Cool Cool Dry 30 Auto Heat Heat Fan ...

Page 27: ...o prevent any injury from sharp edges of the surface when handling the heat exchanger Cleaning the filter CAUTION ŷ Do not scrub the air filter with a brush or other cleaning utensil This may damage the filter ŷ Do not expose the air filter to direct sunlight when drying it NOTE ŷ Clean the air filter every 2 weeks Cleaning term may vary depending on the usage and environmental conditions ŷ If the...

Page 28: ...n ŷ Switch on the circuit breaker plug in the power cord then operate the air conditioner again ŷ Make sure that the isolator is turned on ŷ Check whether the Timed off function is running Operate the air conditioner again by pressing the Power button I cannot change the temperature ŷ Check whether the Fan or Fast mode is running In these modes the air conditioner controls the set temperature auto...

Page 29: ... whether the outdoor unit is covered or installed near obstacles Remove the coverings and obstacles ŷ Check whether the air conditioner is running the defrost function When ice forms in winter or the outdoor temperature is too low the air conditioner runs the defrost function automatically While this function is running the indoor fan stops and warm air does not come out ŷ Check whether doors or w...

Page 30: ...n the Heat mode I cannot change the fan speed ŷ When the Auto Dry or Fast mode is running or the good sleep function is running in the Cool mode the air conditioner controls the fan speed automatically and you cannot change the fan speed The remote control does not work ŷ Replace the batteries in the remote control with new ones ŷ Make sure that nothing is blocking the remote control sensor ŷ Chec...

Page 31: ... Check whether the drains are clean Clean them regularly An error is indicated ŷ If the indoor unit indicator blinks contact the nearest service centre Be sure to pass the error code to the service centre Noise is generated ŷ When refrigerant flow changes noise may be generated depending on the status of the air conditioner This is a normal operation Smoke is generated from the outdoor unit ŷ If m...

Page 32: ...ctions regularly These operations should be performed by qualified personnel only ŷ The unit contains moving parts which should always be kept out of the reach of children ŷ Do not attempt to repair move alter or reinstall the unit If performed by unauthorised personnel these operations may cause electric shocks or fires ŷ Do not place containers with liquids or other objects on the unit ŷ All the...

Page 33: ...es larger than the size of the outdoor unit Also secure a space larger than 23 6inch 600 mm between the protection wall and the outdoor unit for exhausted air to ventilate ŷ Install the unit in a place where water can drain smoothly ŷ If you have any difficulty finding installation location as prescribed above contact your manufacturer for details ŷ Be sure to clean the sea water and the dust on t...

Page 34: ... 49 2ft 15m 26 2ft 8m 7718 2477 9 8ft 3m 98 4ft 30m 49 2ft 15m 3 9inch 100 mm or more 4 9inch 125 mm or more Drain hose hole You can select the direction of draining left or right Maximum pipe height 49 2ft 15m Maximum pipe length 98 4ft 30 m Make at least one round to reduce noise and vibration The actual units may look different from the images depicted here Make a U trap A on the pipe which is ...

Page 35: ...nit is installed with any insufficient clearance it may generate sound and affect the whole product ŷ Be sure to install the outdoor unit in a level place where its vibration does not affect the whole product Step 1 2 Checking and preparing accessories and tools Accessories Accessories in the indoor unit package Installation plate 1 Remote control 1 Manual users Install 1 Remote control battery 2 ...

Page 36: ...e or outdoor unit package ŷ Wired remote controller is optional It has no Filter Reset function in this model ŷ At cool mode when wireless Remote controller temp setting is from 61oF 64oF wired Remote controller FDQ GLVSOD WKH VHWWLQJ WHPS FRUUHFWO EXW FDQŰW VHW TEMP below from 64oF to 61oF Tools General tools ŷ Vacuum pump Backward flowing prevention ŷ Manifold gauge ŷ Stud finder ŷ Torque wrench...

Page 37: ...pipes as shown in the figure This wrapping minimises condensation problem 2 Wind the refrigerant pipes power cable communication cable and drain hose with vinyl tape to make a pipe bundle Possible directions of the pipe bundle Left Right Rear right or left Bottom right Wall Drain hose Indoor unit The hole slants downwards Insulation Refrigerant pipes Refrigerant pipes assembly pipe Installation pl...

Page 38: ...ation ŷ If you need to extend the pipe be sure to extend the cable too The maximum length of each of the cable and pipe used should not exceed 49 2ft 15m 7709 1277 98 4ft 30m 7718 2477 ŷ Do not connect two or more different cables to extend the length This connection may cause fire ŷ Each circular terminal must match the size of its corresponding screw in the terminal block ŷ After connecting the ...

Page 39: ...oints and flip it over and compress another two points in the same location ŷ The compression dimension should be 8 0 ŷ After compressing it pull both sides of the wire to make sure it is firmly pressed 5 Wrap it with the insulation tape twice or more and position your contraction tube in the middle of the insulation tape A total of three or more layers of insulation is required 6 Apply heat to th...

Page 40: ...n hose is smaller than the product s drain hose water leakage may occur ŷ Inadequate installation may cause water leakage ŷ If the drain hose is routed inside the room insulate the hose so that dripping condensation does not damage the furniture or floors ŷ Do not box in or cover the drain hose connection Drain hose connection must be easily accessible and serviceable Step 2 4 Optional Extending t...

Page 41: ...t least 4200 kPa and for burst pressure of at least 20700 kPa Under no circumstances must sanitary type copper pipe be used There are 2 refrigerant pipes of different diameters ŷ The smaller one is for the liquid refrigerant ŷ The larger one is for the gas refrigerant A short liquid refrigerant pipe and a short gas refrigerant pipe are already fitted to the air conditioner The connection procedure...

Page 42: ...e 2 7 Assemble the Guide into the position of A or B as shown in the picture 3 NOTE ŷ The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test For further details see Step 4 1 Performing the gas leak tests on page54 CAUTION ŷ Tighten the flare nut with a torque wrench according to specified method If the flare nut is over tightened the f...

Page 43: ...ght of the indoor unit If you install the indoor unit in a place where it is not strong enough to withstand the unit s weight the unit could fall and cause injury When fixing the indoor unit on a wall Fix the installation plate to the wall giving attention to the weight of the indoor unit NOTE ŷ If you mount the plate to a concrete wall using plastic anchors make sure that gaps between the wall an...

Page 44: ...ou fix the indoor unit on a gypsum board use only specified anchor bolts on reference positions Otherwise the gypsum surrounding the joints may crumble over time and cause the screws to be loosened and stripped This may lead to physical injury or equipment damage ŷ Search for other spots if there are less than two studs or the distance between the studs are different from the plate hanger ŷ Fix th...

Page 45: ...e sure that the wall can support the weights of the rack and the outdoor unit ŷ Install the rack close to the column as much as possible Step 3 2 Connecting the power and communication cables and the refrigerant pipes F1 F2 L1 L2 CAUTION ŷ Be sure to fix the power cables and communication cable with a cable clamp Unit ft mm Model X Y 7709 1277 2 01ft 612mm 1 04ft 317mm 7718 2477 2 16ft 660mm 1 12f...

Page 46: ... better vacuum operation full OPEN position of Electronic Expansion Valve 2 Connect the charging hose of the low pressure side of manifold gauge to a gas service port as seen in the picture Z 3 Open the valve of the low pressure side of manifold gauge anticlockwise 4 Evacuate the air in the connected pipes using the vacuum pump for about 15 minutes ŷ Make sure that pressure gauge shows 0 1 MPa 76 ...

Page 47: ...Important information regulation regarding the refrigerant used This product contains fluorinated greenhouse gases Do not vent gases into the atmosphere CAUTION ŷ Inform user if system contains 5 tCO2 e or more of fluorinated greenhouse gases In this case it has to be checked for leakage at least once every 12 months according to regulation n 517 2014 This activity has to be covered by qualified p...

Page 48: ... amount charged in the field Refer to the above information for the quantity of refrigerant replenishment C Total refrigerant charge d Refrigerant cylinder and manifold for charging CAUTION ŷ The filled out label must be adhered in the proximity of the product charging port e g onto the inside of the stop valve cover ...

Page 49: ...nits with soap lather or liquid Outer diameter inch mm Tightening torque Body cap fWŷOE 1ŷP Charging port cap fWŷOE 1ŷP ø1 4inch 6 35mm 14 8 18 4 20 25 7 4 8 9 10 12 ø3 8inch 9 52mm 14 8 18 4 20 25 ø1 2inch 12 70mm 18 4 22 1 25 30 ø5 8inch 15 88mm 22 1 25 8 30 35 Over ø3 4inch 19 05mm 25 8 29 5 35 40 1ŷP NJIŷFP Tightening torque for body cap Refer to the table Charging core Spindle R 22 Thread of ...

Page 50: ...ed to collect all the system refrigerant in the outdoor unit This operation must be carried out before disconnecting the refrigerant tubing in order to avoid refrigerant loss to the atmosphere 1 Shut off the liquid valve with the Allen wrench 2 Turn on the air conditioner in cooling with fan operating at high velocity Compressor will immediately start provided 3 minutes have elapsed since the last...

Page 51: ...he Cover PCB 3 Attach the Sub PCB to the right side of the Panel frame 4 Find the PCB wire and connect the wire to the Sub PCB as seen in the picture 5 Connect the wire remote controller central remote controller etc to the Sub PCB 6 Assemble the Cover PCB and the front panel NOTE ŷ The Sub PCB is attached to be controlled by the wired remote controller and central controller Case Sub PCB ...

Page 52: ...red Remote controller Wire Joint Quantity 1EA 1EA 4EA Shape Code DB93 11412A DB93 11405A DB96 90020A Wired Remocon 1 2 12V 4 5 COM2 RAC MAIN SUB Connection External controller connection MIM B14 ORG Wired Remote Controller RAC SUB PCB Communication Cable POWER Cable 12V COM2 ORG RED RED YEL YEL BLU BLU Wired remote controller installation optional ...

Reviews: