3.  Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter 

of 65 mm so that it slants slightly downwards.

Wall

< 20 mm

Plastic 

Anchor

4.  Fix the indoor unit.
If you fix the indoor unit on a wall 

(1)   Fix the installation plate to the wall giving attention to the weight of the indoor unit. 

If you fix the indoor unit on a window frame 

(1)   Determine the positions of the wooden uprights to be attached to the window frame. 
(2)   Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.
(3)   Attach the installation plate to the wooden upright using tapping screws.

If you fix the indoor unit on a gypsum board 

(1)   Use stud finder to find out locations of the studs. 
(2)  Fix the plate hanger on two studs.

•   If you mount the plate to a concrete wall using plastic anchors, make sure that gaps 

between the wall and the plate, created by projected anchor, is less than 20 mm.

•   Search for other spots if there are less than two studs, or the distance between the studs are different from the 

plate hanger.

•  Fix the installation plate without inclining to one side.

•   Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not 

strong enough to withstand the product weight, the unit could fall and cause injury.

•   Make sure to drill only one hole after choosing the 

direction of the pipe.

(Unit : mm)

Model

A

B

C

D



12



36 120 81

36



18



33 110 110

33

Assembling the hanger screw

Use 2 screws to fix the indoor unit with hanger plate as shown in the picture.

Screw(M4x10)

B

A

D

C

B

A

D

C

B

A

D

C

Pipe hole (Ø65 mm)

Pipe hole (Ø65 mm)

1.  Disassemble the cover panel as described in page 37~38.
2.  Remove the Hanger plate from the indoor unit.
   (1) Unscrew 2 screws that fixes the Hanger plate to the indoor unit.
   (2) Push the hooks (on the bottom part of the indoor unit) up to release the installation plate from the hooks that holds it.
   (3) Pull the installation plate to release it completely from the indoor unit.

Screw(M4x10)

Screw (M4x10)

NA_BETTER_A3050_IB&IM_EN_DB68-04388A-00.indd   36

12/23/2013   10:25:27 PM

Summary of Contents for AR**HV5D series

Page 1: ...duct at www samsung com register This manual is made with 100 recycled paper AR HV5D Series Air Conditioner user installation manual imagine the possibilities ThankyouforpurchasingthisSamsungproduct To receive more complete service please register your product at www samsung com register This manual is made with 100 recycled paper NA_BETTER_A3050_IB IM_EN_DB68 04388A 00 indd 1 12 23 2013 10 24 52 ...

Page 2: ...tall When the installation is done your product will examine itself through trial operation to check if it was installed properly EasyInstallation It s so easy to install You can easily hang the product on the wall and connect the pipes and wires by opening the cover on the bottom of the product Now you won t have to tilt the product to connect the pipe and the wires function function will allow y...

Page 3: ...ecautions 30 Choosing the installation location 31 Accessories 34 Fixing the installation plate 35 Disassembling Assembling the Cover panel for indoor unit installation 37 Connecting the assembly cable 39 Installing and connecting the assembly pipe of the indoor unit 41 Evacuating the indoor unit 42 Cutting or extending the pipe 42 Installing and connecting the drain hose of the indoor unit 44 Cha...

Page 4: ...NG Use the power line with the power specifications of the product or higher and use the power line for this appliance only In addition do not use an extension line Extending the power line may result in electric shock or fire Do not use an electric transformer It may result in electric shock or fire If the voltage frequency rated current condition is different it may cause fire The installation o...

Page 5: ...ormal vibrations noise or problems with the product Install the draining hose properly so that water is drained correctly Failing to do so may result in water overflowing and property damage Avoid adding drain to waste pipes as odours may arise in the future When installing the outdoor unit make sure to connect the draining hose so that draining is performed correctly The water generated during th...

Page 6: ...service center Failing to do so may result in problems with the product water leakage electric shock or fire A delivery service for the product is not provided If you reinstall the product in another location additional construction expenses and an installation fee will be charged Especially when you wish to install the product in an unusual location such as in an industrial area or near the seasi...

Page 7: ...th the product FOR USING WARNING Do not place an object near the outdoor unit that allows children to climb onto the machine This may result in children seriously injuring themselves Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people Since this may be dangerous due to a lack of oxygen Open a window at least once an hour If any foreign subst...

Page 8: ...perate the appliance with wet hands This may result in electric shock Do not spray volatile material such as insecticide onto the surface of the appliance As well as being harmful to humans it may also result in electric shock fire or problems with the product Do not drink the water from the air conditioner The water may be harmful to humans Do not apply a strong impact to the remote controller an...

Page 9: ...deformation damage electric shock or fire Before cleaning or performing maintenance cut off the power supply and wait until the fan stops Failing to do so may result in electric shock or fire FOR CLEANING CAUTION Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges This should be done by a qualified technician please contact your installer or servi...

Page 10: ...ype Description Against cold air The internal fan will be off to prevent cold air when the heat pump is heating Defrost cycle The internal fan will be off to defrost ice when the heat pump is heating Vertical air flow blade will be closed during defrost cycle and it will open again during heating operation after defrost cycle Protect compressor The air conditioner does not start operating immediat...

Page 11: ...r display Press the 2nd F button and then press the Usage button on the remote controller while the air conditioner is operating When the air conditioner is not in use power consumption will not be displayed on the indoor unit display even if you press the 2nd F Usage button Indoor unit will display the amount of Power consumption for few seconds and then return to usual status by displaying the i...

Page 12: ...re indicator Filter Reset indicator Power consumption indicator Auto clean indicator Timer Auto Clean indicator Single User indicator Power button Remote controller receiver Air filter Air flow blade upanddown Air flow blade leftandright Virus Doctor Lamp Room temperature sensor Air intake Virus Doctor NA_BETTER_A3050_IB IM_EN_DB68 04388A 00 indd 12 12 23 2013 10 24 57 PM ...

Page 13: ... and right Mode Set one of the 5 operating modes see pages 15 16 for instructions Quiet Reduce noise generated from an indoor unit during operation Power Turn on off the air conditioner Temp Increase Decrease the temperature by 1 C d light Cool The d light Cool function is not available for this model Set the mode on Fast Comfort Select Fast function or Comfort function VirusDoctor Set the VirusDo...

Page 14: ...that the water does not get to the remote controller Fast Comfort indicator Quiet indicator Set temperature indicator VirusDoctorindicator 2nd F indicator Single User indicator d light Cool indicator OnTimer indicator OffTimer indicator indicator Operation mode indicator Fanspeedindicator Auto Low Medium High Turbo Low battery indicator Air swing indicator Vertical Horizontal Transmit indicator Ch...

Page 15: ...n Cool mode the air conditioner will cool your room You can adjust the temperature and the fan speed to feel cooler in hot season If current outside temperature is much higher than the selected indoor temperature it may take time to bring the inner temperature to the desired coolness Quiet mode makes the noise quieter during the operation of the indoor unit in the Cool mode Heat The air conditione...

Page 16: ... Auto Low Med High Turbo Dry Auto Fan Low Med High Turbo Heat Auto Low Med High Turbo Press the button to adjust the temperature Auto 2 Step Cooling or Heat You can adjust the desired temperature by 1 C within the range of 16 C 30 C Cool You can adjust the desired temperature by 1 C within the range of 16 C 30 C Dry You can adjust the desired temperature by 1 C within the range of 18 C 30 C Fan Te...

Page 17: ...ioner Press the Horizontalairswing button on the remote controller Air swing indicator will be on the remote controller display and air flow blades move left and right continuously to circulate the air Press the Horizontalairswing button on the remote controller again to keep the air flow direction in a constant position If you adjust the horizontal air flow blade manually it may not operate norma...

Page 18: ...but fan speed cannot be adjusted when the function is on Press the Fast Comfortbutton on the remote controller once to select Fast function Fast indicator appears on the remote controller display and the air conditioner operates in Fast function for 30 minutes When you select Fast function your air conditioner will operate more powerfully to quickly cool or warm your room Press the Fast Comfortbut...

Page 19: ...You fell disturbed sleep if the is set too short or long because the default is set to 8 hour operation If the mode is set less than 4 hours the operation will stop at the same time If the mode is set over 5 hours it will run asWake up stage from the last one hour before it stops Recommended set temperature is between 25 C 27 C for cooling and 21 C 23 C for heating Temperature and fan speed change...

Page 20: ...onds If you don t press Set Cancel button within 10 seconds after selecting the time the air conditioner will return to previous status Check On timer or Off timer indicator on the remote controller display and indicator on the indoor unit Only the latest setting timer will be applied between the OnTimer OffTimer and Off timer functions After setting the timer the set time will be displayed for 3 ...

Page 21: ...s operating in Cool Heat mode Press the SingleUser button on the remote controller while the air conditioner is operating in Cool Heat mode appears on the remote controller display for few seconds and disappears Single User indicator and air swing indicator appear automatically on the remote controller display The air flow blades move up and down If the current set temperature is lower than 24 C i...

Page 22: ...moisture inside of the indoor unit Activate this function to help provide you with clean air Press the AutoClean button During the auto clean function indoor fan will continue to run and air flow blade will remain open to expel ambient air lighting in Auto clean mode Whentheairconditioneristurnedoff The Auto clean indicator on the indoor unit display appears and the Auto clean function runs Whenth...

Page 23: ...ng the Quiet function You can reduce the noise generated from an indoor unit Press the Quiet button on the remote controller while the air conditioner is operating in Cool Heat mode Quiet indicator appears on the remote controller display The indoor unit will operate more quietly Single User Fast Comfort If using a multi system this function will work only when the Quiet function is set on all ope...

Page 24: ...d you should use a micro fiber cloth to clean the panel When you use the micro fiber cloth slightly dampen the cloth and remove any debris on the cloth to avoid scratches Heatexchanger Illustration may differ slightly depending on the models Make sure to turn off the power of the indoor unit and cut off the power supply before cleaning the air conditioner CAUTION Do not clean the display using alk...

Page 25: ... main body Insert the Air filter back in its original position Dry the Air filter in a ventilated area Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy rinse it with running water Clean the Air filter every 2 weeks Cleaning term may differ depending on the usage and environmental conditions In dusty area clean it once a week If the Air filter dries in a confined or hum...

Page 26: ...are in the top of the Air filter into the main body Air filter 2 There s one hook in both side of the filter press the surface of the Air filter softly and get the hooks into the main body 3 Press the bottom of the filter lightly to securely fix the main body NA_BETTER_A3050_IB IM_EN_DB68 04388A 00 indd 26 12 23 2013 10 25 18 PM ...

Page 27: ...he condensate drain pan 2 Thoroughly clean the heat exchanger 2 Clean the cross fan 2 Clean the condensate drain pipe 2 Replace the remote controller batteries 1 Outdoor unit Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of air 2 Verify that all the electric components are firmly tightened 2 Clean ...

Page 28: ...lockedbydirt Ifthereisalotofdustonthe Airfilter cooling heating performancemaydecrease Cleanthem frequently Checkiftheoutdoorunitiscoveredorinstalledneartheobstacle Takethecoveroffandtaketheobstacleaway CheckiftheairconditionerisoperatinginDefrostmode When theiceformedinwinterortheoutdoortemperatureistoolow the airconditioneroperatesinDefrostmodeautomatically InDefrost mode indoorfanstopsandwarmai...

Page 29: ...g contacttheservicecenter Odorspermeatein theroomduring operation Checkiftheapplianceisrunninginasmokyarea Ventilatethe roomoroperatetheairconditionerinFanmodefor1 2hours Wedonotusesmellycomponentsintheairconditioner ChecktheDrainshavebeenclearedRegularMaintenance Errorisindicated Whenanindoorunitindicatorblinks contactthenearestservice center Pleaseensuretheerrorcodeispassedontotheservice centerw...

Page 30: ...ts set forth in the Operating limits table included in the manual shall immediately invalidate the warranty The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Do not use the units if damaged If problems occur switch the unit off and disconnect it from the power supply In order to help...

Page 31: ...ays make sure that the power supply is compliant with current safety standards Always install the air conditioner in compliance with current local safety standards Always verify that a suitable grounding connection is available Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other dom...

Page 32: ...or directly under eaves for accessibility for service and OH S reasons Avoid the following places to prevent malfunction of the unit Where there is machine oil Salty environment such as seaside areas Where sulfide gas exists Other special atmosphere areas 125 mm or more 300 mm or more 125 mm or more 600 mm minimum 300 mm minimum 300 mm minimum 600 mm minimum L meters maximum total pipe length Wrap...

Page 33: ...500 or more 300 or more The upper part of the outdoor unit and the air outlet is opposite the wall When the walls are blocking front and the rear side of the outdoor unit 300 or more 1500 or more Top view Side view Air outlet Air intake Air intake Air outlet Figure Description Air flow direction Unit mm When installing more than 1 outdoor unit Unit mm 1500 or more When the air outlet is towards th...

Page 34: ...enerate sound and cause bad effect on the product Installation must be done in level and in a place where vibration will not cause any effect Choosing the installation location Installation Plate 1 12 Installation Plate 1 18 Remote controller 1 User s Installation Manual 1 BatteriesforRemote controller 2 Remote Control Holder 1 M4 x 16Tapped Screws 2 Cap Screws 3 Accessories The following accessor...

Page 35: ...ly Pipe Ø6 35 mm x 5 m 1 Insulated Assembly Pipe Ø12 70 mm x 5 m 1 12 Insulated Assembly Pipe Ø15 88 mm x 5 m 1 18 PET3 FoamTube Insulation 1 VinylTapes 2 Drain Hose length 2 m 1 Putty 100 g 1 Pipe Clamps A 3 Pipe Clamps B 3 Cement Nails 6 M4 x 25Tapped Screws 6 Drain Plug 1 3 wire Power Cable 1 2 wire Assembly Cable 1 3 wire Assembly Cable 1 Fixing the installation plate You can select the direct...

Page 36: ...20 mm Search for other spots if there are less than two studs or the distance between the studs are different from the plate hanger Fix the installation plate without inclining to one side Make sure that a wall can withstand the weight of the product If you install the product in a place where it is not strong enough to withstand the product weight the unit could fall and cause injury Make sure to...

Page 37: ...en the screws so that you can disassemble the cover panel Cap Screw Remove the Cap screw Unfasten the screw Cover Panel Removing the Cover panel Before mounting the indoor unit The bottom panel fits the main body using the side center and bottom hooks as shown Unlock the side hooks first and then unlock the center and bottom hooks Check the location of the hooks before removing the cover panel f f...

Page 38: ...it up at an angle Assembling the Cover panel After mounting the indoor unit To assemble the Cover panel proceed in reverse order of disassembling Use both hands for assembling and be extra careful not to damage the pipes and drain hose Lock the side center and bottom hooks in this sequence Tighten the bottom panel with the screws and close the screw holes with their cap Lock the side hook Fasten t...

Page 39: ...g part of the terminal socket is facing upwards Upside down The terminal socketis damaged There is no ring terminalto cover the wire There must be no space between the terminal and the screw when connected Any remaining space may become a fire hazard due to overheating of the electrical contact The terminal socket is upside down Either the screw is not fitted properly or there is a space between t...

Page 40: ...ot connect two or more different cables to extend the length It may cause fire When you install the unit make first refrigerant connections and then electrical connections Connect the air conditioner to grounding system before performing the electrical connection If unit is uninstalled first disconnect electrical cables then refrigerant connections If the outdoor unit is more than 5 meters away fr...

Page 41: ...The connection procedure for the refrigerant pipe varies according to the exit position of the pipe when facing the wall Right A Left B Underside C Rear B A C Outer Diameter Torque N m kgf cm ø6 35 mm 14 18 140 180 ø9 52 mm 34 42 350 430 ø12 70 mm 49 61 500 620 ø15 88 mm 68 82 690 830 If you want to shorten or extend the pipes refer to page 42 43 4 Cut off the remaining foam insulation 5 If necess...

Page 42: ... end of each pipe All inert gas exhausts from the indoor unit The indoor unit is supplied with inert gas nitrogen Before installing the unit check if nitrogen gas flow out of indoor unit If this one isn t true DO NOT INSTALLTHE UNIT since leakage could be inside the indoor unit Unscrew the caps Pipes 1 Make sure that you have all the required tools pipe cutter reamer flaring tool and pipe holder 2...

Page 43: ...tending pipe by welding brazing please ensure nitrogen is used during welding brazing process The joint must be accessible and serviceable Tighten the flare nut with torque wrench according to specified method If the flare nut is over tightened the flare may break and cause refrigerant gas leakage 4 Put a flare nut slightly into the pipe and modify the flare Outer Diameter D Depth A Flaring Size B...

Page 44: ...htly with a clamp 4 When extending the Drain Hose hold the end of Drain Hose and Extended Hose rotate and insert the drain hose into Extended hose for 40 45 mm Make sure the two hoses are firmly connected there is no water leakage 5 Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose Then Use vinyl tape to wrap the each side of connection by 20 mm Drain hose Extension drai...

Page 45: ...verflow onto the electrical part Change the direction only when it is necessary 1 Detach the rubber cap with the pliers 2 Detach the drain hose by pulling it and turning to the left 3 Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan 4 Attach the rubber cap with a screwdriver by turning it to the right until it fixes to the end of t...

Page 46: ... Gas pipe side Liquid pipe side Excessive torque can be cause of gas leakage 3 Connect the charging hose of the low pressure side of manifold gauge to a gas service port as seen in the picture 4 Open the valve of the low pressure side of manifold gauge counterclockwise 5 Evacuate the air in the connected pipes using the vacuum pump for about 15 minutes Make sure that pressure gauge shows 0 1 MPa 7...

Page 47: ...sional installation agency for product installation Add refrigerant charge according to table below If you use a pipe longer than 5 m A g of refrigerant R 410A must be added for each extra meter If you use a pipe shorter than 5 m The evacuating time is normal Refer to the Service Manual for further details Adding Refrigerant Model A 12 18 15 NA_BETTER_A3050_IB IM_EN_DB68 04388A 00 indd 47 12 23 20...

Page 48: ...efrigerant Important information regulation regarding the refrigerant used Charging the refrigerant under conditions of liquid by using a liquid pipe a Factory refrigerant charge of the product see unit name plate b Additional refrigerant amount charged in the field Refer to the above information for the quantity of refrigerant replenishment c Total refrigerant charge d Refrigerant cylinder and ma...

Page 49: ...re Shut off the liquid valve with the Allen wrench Turn the system on in cooling with fan operating at high velocity Compressor will immediately start provided 3 minutes have elapsed since the last stop After 2 minutes of operation shut the suction valve with the same wrench Turn the system off and switch mains supply off Disconnect tubing After disconnection protect valves and tubing ends from du...

Page 50: ... 1 Place the outdoor unit as indicated on the top of the unit to let the discharged air out properly 2 Fix the outdoor unit in level to an appropriate support using anchor bolts 3 If the outdoor unit is exposed to strong winds install shield plates around the outdoor unit so that the fan can operate correctly 5 Wrap the rest of the pipe with vinyl tape 6 Attach the pipe to the wall using clamps op...

Page 51: ...al refrigerant required for pipe extension 2 Status of the indicator after supplying the power Standby status 2 When the air conditioner is in standby status use the remote controller to start the Smart Install mode 1 Press the Set Cancel or Cancel Mode Power button simultaneously for 4 seconds f f Smart Install mode can be operated only with the supplied remote controller f f During the Smart ins...

Page 52: ...play 1 Take necessary measures when error occurs Refer to the service manual for necessary measures for each error that occurs 2 Use the product after taking care of the error that occurs Error indicator Error Measures to take by an installer Display LED Display LED 1 LED 2 LED 3 Error on indoor temperature sensor 1 Check the connection of the connector Error on indoor heat exchanger 1 Check the c...

Page 53: ...g mode indoor unit check Inlet air temp Outlet air temp From 10 C to 12 C indicative deltaT Heating mode indoor unit check Outlet air temp Inlet air temp From 11 C to 14 C indicative deltaT In heating mode the indoor fan motor can remain off to avoid cold air blown into conditioned space Approximately 3 5 minutes later outdoor unit will start to operate and the Cool orWarm air will blow out After ...

Page 54: ...insulation tape twice and position your contraction tube in the middle of the insulation tape 5 Apply heat to the contraction tube to contract it 6 After tube contraction work is completed wrap it with the insulation tape to finish Tools Crimping pliers Connectionsleeve mm Insulation tape Contractiontube mm Spec MH 14 20xØ7 0 HxOD Width 18 mm 50xØ8 0 LxOD Shape 40 mm Insulation tape Contraction tu...

Page 55: ...English 55 NA_BETTER_A3050_IB IM_EN_DB68 04388A 00 indd 55 12 23 2013 10 25 46 PM ...

Page 56: ...QUESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT INDIA 1800 3000 8282 1800 266 8282 www samsung com in NA_BETTER_A3050_IB IM_EN_DB68 04388A 00 indd 56 12 23 2013 10 25 46 PM ...

Reviews: