Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.

•  Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components.
•  Verify that installation and testing operations are performed by qualified personnel. 
•  Verify that the air conditioner is not installed in an easily accessible area.

General information

 

Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order 

to be able to use it as reference after installation. 

   For maximum safety, installers should always carefully read the following warnings.

 

   Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air 

conditioner is sold or transferred.

   This manual explains how to install an indoor unit with a split system with two SAMSUNG units. 

The use of other types of units with different control systems may damage the units and invalidate the warranty. 

 

The manufacturer shall not be responsible for damages arising from the use of non compliant units.

   This product has been determined to be in compliance with the Low Voltage Directive (2006/95/EC), and the 

Electromagnetic Compatibility Directive (2004/108/EC) of the European Union.

   The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection 

of electric and requirements set forth in the “Operating limits” table, included in the manual, shall immediately invalidate 

the warranty.

   The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable 

to be installed in areas used for laundry.

   Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.

   In order to h

elp 

prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact 

SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.

   Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations 

should be performed by qualified personnel only.

   The unit contains moving parts, which should always be kept out of the reach of children.

   Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may 

cause electric shocks or fires.

   Do not place containers with liquids or other objects on the unit.

   All the materials used for the manufacture and packaging of the air conditioner are recyclable.

   The packing material and exhaust batteries of the remote controller(optional) must be disposed of in accordance with 

current laws.

   The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air 

conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and 

safely.

Installing the unit

IMPORTANT:  When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. 

 

Always disassemble the electric lines before the refrigerant tubes.

 

Upon receipt, inspect the product to verify that it has not been damaged during transport. 

If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the 

installer or the authorized technician has collected the material from the retailer.)

Safety precautions

Installation

English-3

A3050 EU_IM_DB68-04212A_HP_EN.indd   3

2013-10-23   16:31:10

Summary of Contents for AR**HSFS Series

Page 1: ...A3050 EU_IM_DB68 04212A_HP_EN indd 1 2013 10 23 16 31 10...

Page 2: ...15 Installing and connecting the drain hose of the indoor unit 17 Changing direction of the drain hose 18 Installing and connecting the drain hose of the outdoor unit 19 Evacuating the connected pipes...

Page 3: ...areas used for laundry Do not use the units if damaged If problems occur switch the unit off and disconnect it from the power supply In order to help prevent electric shocks fires or injuries always s...

Page 4: ...the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines Always verify t...

Page 5: ...and OH S reasons Avoid the following places to prevent malfunction of the unit Where there is machine oil Salty environment such as seaside areas Where sulfide gas exists Other special atmosphere area...

Page 6: ...opposite the wall When the walls are blocking front and the rear side of the outdoor unit 300 or more 1500 or more Top view Side view Air outlet Air intake Air intake Air outlet Figure Description Air...

Page 7: ...ate sound and cause bad effect on the product Installation must be done in level and in a place where vibration will not cause any effect The following accessories are supplied with the air conditione...

Page 8: ...ingTape Tools for test operations Thermometer Resistance Meter Electroscope Optional accessories The following connection accessories are optional If they are not supplied you should obtain them befor...

Page 9: ...hed to the window frame 2 Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit 3 Attach the installation plate to the wooden upright using tapping screws If...

Page 10: ...you can disassemble the cover panel Cap Screw Remove the Cap screw Unfasten the screw Cover Panel Removing the Cover panel Before mounting the indoor unit Cover panel is fixed to a main body of the pr...

Page 11: ...ling the Cover panel After mounting the indoor unit To assemble the Cover panel proceed in reverse order of disassembling Use both hands for assembling and be extra careful not to damage the pipes and...

Page 12: ...overheating of the electrical contact during a wiring work 1 Extend the assembly cable if necessary Do not connect two or more different cables to extend the length It may cause fire When you install...

Page 13: ...in terminal block After connecting the cables make sure terminal numbers on the indoor outdoor unit matches Please ensure that Power Communication cables are separated they must not be in the same cab...

Page 14: ...on procedure for the refrigerant pipe varies according to the exit position of the pipe when facing the wall Right A Left B Underside C Rear B A C Outer Diameter Torque N m kgf cm 6 35 mm 14 18 140 18...

Page 15: ...up to see page 5 If you need a pipe longer than 4 or 5 meters You must add refrigerant to the pipes otherwise the indoor unit may freeze Cutting or extending the pipe 1 Unscrew the caps at the end of...

Page 16: ...For further details on how to connect to the outdoor unit and evacuate the air refer to page 19 21 Correct Uneven Thickness Cracked Damaged Surface Inclined Excessive torque can be cause of gas leakag...

Page 17: ...with a clamp 4 When extending the Drain Hose hold the end of Drain Hose and Extended Hose rotate and insert the drain hose into Extended hose for 40 45 mm Make sure the two hoses are firmly connected...

Page 18: ...t is necessary 1 Detach the rubber cap with the pliers 2 Detach the drain hose by pulling it and turning to the left 3 Insert the drain hose by fixing it with the screw into the groove of the drain ho...

Page 19: ...iling on the outdoor unit The outdoor unit is loaded with sufficient R 410A refrigerant Do not vent R 410A into atmosphere it is a fluorinated greenhouse gas covered by Kyoto Protocol with a GlobalWar...

Page 20: ...ose the valve of the low pressure side of manifold gauge clockwise Turn off the vacuum pump Check for 2 minutes if there is any pressure change Remove the hose of the low pressure side of manifold gau...

Page 21: ...rant Important information regulation regarding the refrigerant used Charging the refrigerant under conditions of liquid by using a liquid pipe a Factory refrigerant charge of the product see unit nam...

Page 22: ...ss to the atmosphere Shut off the liquid valve with the Allen wrench Turn the system on in cooling with fan operating at high velocity Compressor will immediately start provided 3 minutes have elapsed...

Page 23: ...cated on the top of the unit to let the discharged air out properly 2 Fix the outdoor unit in level to an appropriate support using anchor bolts 3 If the outdoor unit is exposed to strong winds instal...

Page 24: ...or pipe extension 2 Status of the indicator after supplying the power Standby status 2 When the air conditioner is in standby status use the remote controller to start the Smart Install mode 1 Press t...

Page 25: ...1 Take necessary measures when error occurs Refer to the service manual for necessary measures for each error that occurs 2 Use the product after taking care of the error that occurs Error indicator E...

Page 26: ...unit check Inlet air temp Outlet air temp From 10 C to 12 C indicative deltaT Heating mode indoor unit check Outlet air temp Inlet air temp From 11 C to 14 C indicative deltaT In heating mode the indo...

Page 27: ...tion tape twice and position your contraction tube in the middle of the insulation tape 5 Apply heat to the contraction tube to contract it 6 After tube contraction work is completed wrap it with the...

Page 28: ...wire to the Sub PCB as seen in the picture 5 Connect the wire remote controller central remote controller etc to the Sub PCB 6 Assemble the Cover PCB and the front panel The Sub PCB is attached to be...

Page 29: ...English 29 A3050 EU_IM_DB68 04212A_HP_EN indd 29 2013 10 23 16 31 18...

Page 30: ...DB68 04212A 00 A3050 EU_IM_DB68 04212A_HP_EN indd 30 2013 10 23 16 31 18...

Page 31: ...w samsung com register This manual is made with 100 recycled paper AR HSFS Series AR HSFN Series AR HSSD Series Air Conditioner user installation manual imagine the possibilities Thankyouforpurchasing...

Reviews: