12
English
Ins
tallation
WARNING
•
In case of extending the electric wire, please DO NOT
use a round-shaped pressing socket.
– Incomplete wire
connections can cause
electric shock or a fire.
Step 2.5 Installing and connecting the
drain hose
1
Install the drain hose.
2
Pour water into the drain pan. Check whether the hose
is well drained.
CAUTION
•
Make sure that the indoor unit is in upright position
when you pour water to check for leakage. Make sure
that the water does not overflow onto the electrical
part.
•
If the diameter of the connection hose is smaller than
the product's drain hose, water leakage may occur.
•
Inadequate installation may cause water leakage.
•
If the drain hose is routed inside the room, insulate the
hose so that dripping condensation does not damage
the furniture or floors.
•
Do not box in or cover the drain hose connection.
Drain hose connection must be easily accessible and
serviceable.
Step 2.6 Optional: Extending the drain
hose
(A)
(B)
Drain hose
Assembly pipe
Connection hose
Indoor unit
Drain hose
Wall
5 cm
less
Ditch
Slant downwards
Slant upwards
Dipped in water
Bent
Too small
clearance
Too small
clearance
Drain hose (A)
Extension drain hose (B)
Drain hose
Extension drain hose
20 mm or more
Foam insulation
Vinyl tape
40~45mm
A3050_EU_Best model_IM_DB68-06152A-00_EN.indd 12