background image

E-

11

ENGLISH

Selecting the Heat Mode            

You can select the Heat mode if you want to heat your room.
You can adjust the temperature and the fan speed when heating.

1

If necessary, press the         (On/Off) button.
Result:        



The operation indicator on the indoor unit lights up. 



The air conditioner starts up in the mode you selected last. 



The indoor unit beeps.

2

Press the         button on the remote control until 

 is displayed.

Result:        



The indoor unit beeps each time you press the         button.  



The air conditioner runs in the Heat mode. 

      

Note

           You can change modes at any time.

 

3

Press the                 button to adjust the temperature until the required  

temperature is displayed.  

You can set the temperature between 61°F(16°C) and 86°F(30°C).
Result:       



Each time you press the                 button:  

- The temperature is adjusted by 1°F  

- The indoor unit beeps

                      



If the room temperature reaches 9°F higher than the set  

temperature, the air conditioner stops heating, but the fan  

operates consistently.

                      



If the room temperature reaches 5°F lower than the set  

temperature, the air conditioner starts heating again.

4

Press the            button to select the fan speed until the required settingis  

displayed.

                          Automatic (rotated : 

  



  



)

                          Low
                          Medium
                          High
                          Maximum

Result:        



Each time you press the            button, the indoor unit beeps. 



For the first 3~5 minutes, the fan may not operate to prevent  

the cool air from running out of the indoor unit.  

It helps to warm the air in your room sufficiently.

5

To control the airflow direction, refer to pages 16 and 17.

                                                                                              Air Marketing Group LLC 
141 Kinderkamack Rd, Park Ridge, NJ 07656  Tel: 201-782-1782  Fax: 201-782-1783 Web: www.amgair.com Email: [email protected]

 

Summary of Contents for AQV36W

Page 1: ...onditioner Cooling and Heating USER SMANUAL AQV36W E DB98 29386A 1 ESPAÑOL FRANÇAIS S F Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 Web www amgair com Email info amgair com ...

Page 2: ...E 1 ENGLISH Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 Web www amgair com Email info amgair com ...

Page 3: ...r store or load the air conditioner upside down or sideways to prevent the damage of the compressor Young children or infirm persons should be always supervised when they use the air conditioner Max current is measured according to IEC standard for safety Current is measured according to ISO standard for energy efficiency OTHERS Before throwing out the air conditioner remove the batteries from the...

Page 4: ...Adjusting the Airflow Direction Vertically 16 Adjusting the Airflow Direction Horizontally 17 Setting the On Timer 18 Setting the Off Timer 19 Setting the Sleep Timer 20 Setting the 1 Hour Timer 21 RECOMMENDATIONS FOR USE Operating Recommendations 22 Temperature and Humidity Ranges 23 OperatingYour Air ConditionerWithout the Remote Control 23 Troubleshooting Guide 24 CleaningYour Air Conditioner 2...

Page 5: ...er under the grille Airflow blades outlet Air Inlet Timer indicator Fan mode indicator Turbo indicator Energy saving indicator Power On Off button Remote Control Sensor Operation indicator Cool Heat mode Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 Web www amgair com Email info amgair com ...

Page 6: ...NGLISH Outdoor Unit Air Outlet ConnectionValve Air Inlet Rear AQV36W Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 Web www amgair com Email info amgair com ...

Page 7: ...Airflow direction Fan speed indicator Turbo button 1 Hour Timer button Fan speed button Airflow control button Timer Set Cancel button Battery check button Operation modes indicator AUTO COOL DRY FAN HEAT Note Each mode indicator shows the current setting and the battery life You can check the battery life by pressing the button The number of the battery life indicator means the remaining battery ...

Page 8: ...atteries together Batteries may be completely discharged after 12 months even if they have not actually been used 1 Remove the battery cover in the rear of the remote control by pushing it with your thumb 2 Insert two batteries respecting the polarities as indicated by the and symbols 3 Close the cover by sliding it back in its place Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 ...

Page 9: ...res You have already seen the basic description of the unit on pages from 4 to 6 Starting up with the next page you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use three different symbols PRESS PUSH HOLD DOWN Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 Web www amgair...

Page 10: ...utton The air conditioner runs in the Auto mode The Auto mode cools or heats the room depending on the set temperature The air conditioner changes the Cool or Heat mode automatically depending on the current temperature during operation Note You can change modes at any time 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between ...

Page 11: ...rature between 61 F 16 C and 86 F 30 C Result Each time you press the button The temperature is adjusted by 1 F The indoor unit beeps If the room temperature is higher than the selected temperature the air conditioner starts cooling If the room temperature reaches the set temperature the air conditioner stops cooling but the fan operates consistently 4 Press the button to select the fan speed unti...

Page 12: ...0 C Result Each time you press the button The temperature is adjusted by 1 F The indoor unit beeps If the room temperature reaches 9 F higher than the set temperature the air conditioner stops heating but the fan operates consistently If the room temperature reaches 5 F lower than the set temperature the air conditioner starts heating again 4 Press the button to select the fan speed until the requ...

Page 13: ...ress the button The air conditioner runs in the Dry mode Note You can change modes at any time 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 61 F 16 C and 86 F 30 C Result Each time you press the button The temperature is adjusted by 1 F The indoor unit beeps The air conditioner starts dehumidifying and the fan speed is...

Page 14: ...tton on the remote control until is displayed Result The indoor unit beeps each time you press the button The air conditioner runs in the Fan mode The temperature is set automatically Note You can change modes at any time 3 Press the button to select the fan speed until the required setting is displayed Low Medium High Result Each time you press the button the indoor unit beeps 4 To control the ai...

Page 15: ...matically The air conditioner cools or heats the room as quickly as possible After 30 minutes the air conditioner is reset automatically to the previous setting You can select theTurbo function in the Auto Cool and Heat mode If you select this function in the Dry or Fan mode the mode changes to the Auto mode 3 Press the button again to stop theTurbo Function before the end of the 30 minute period ...

Page 16: ...ditioner runs in the Energy saving mode The outer airflow blade moves up and down To stop the Energy saving mode press the again Note You can select the Energy saving mode only in the Cool and Heat mode 3 Press the button to adjust the temperature until the required temperature is displayed 4 Press the button to select the fan speed until the required setting is displayed 5 To control the airflow ...

Page 17: ...ion is set Result The outer blade is adjusted vertically 2 Press the button to move the blade up and down automatically during operation 3 Press the button again to stop the blade moving up and down Note If you turn the air conditioner Then the blade Off is closed completely On set to the default position Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 ...

Page 18: ...orizontally with your hands The inner blades with small fins moves the air to the required direction 1 Adjust the inner blades by moving them to left or right Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 Web www amgair com Email info amgair com ...

Page 19: ...s The air conditioner turns on automatically at the appointed time and the OnTimer setting disappears 3 Press the button until the desired mode is displayed at the top of theremote control to select the mode in advance Result The air conditioner operates in the selected mode when it is turned on Note If you don t use the remote control after setting the OnTimer it turns off automatically after 25 ...

Page 20: ...tting Result The remaining time is displayed The timer indicator stops blinking The air conditioner turns off automatically at the appointed time and the OffTimer setting disappears Example If you would like to turn the air conditioner on after 2 hours and to operate it for 2 hours 1 Press the button until 2 0 Hr is displayed 2 Press the button 3 Press the button until 4 0 Hr is displayed 4 Press ...

Page 21: ...o longer displayed The air conditioner operates normally You can set the Sleep Timer to turn off the air conditioner automatically while you are sleeping The air conditioner stops operating 6 hours after you set the Sleep Timer 1 Press the button until the indicator appears on the remote control Result The indoor unit beeps The air conditioner will be controlled as indicated in the illustrations be...

Page 22: ...only one button 1 Press the button until the indicator appears on the remote control 2 Press the button until the desired mode is displayed at the remote control to select the mode after setting the 1 HourTimer Result The air conditioner operates in the selected mode for an hour Note If you set the 1 HourTimer when the air conditioner is turned off the air conditioner turns on and operates for an ...

Page 23: ...his happens The heating operation is stopped The air conditioner defrosts automatically for about 7 minutes After about 7 minutes the air conditioner starts operating again normally High indoor and outdoor temperatures If both the indoor and outdoor temperatures are high when you select the Heat mode the fan and the compressor of the outdoor unit may stop at times This is normal wait until the air...

Page 24: ...oor temperature is as low as 32 F 0 C the heating capacity drops up to 70 80 depending on the operating condition If you use the air conditioner over 90 F 32 C indoor temperature the cooling capacity may drop Operating Your Air Conditioner Without the Remote Control You can operate your air conditioner directly without the remote control 1 To turn the air conditioner on press the On Off button on ...

Page 25: ...ary The air conditioner does not cool or heat Check if the correct operating mode has been selected Auto Cool Heat The room temperature may be too low or too high Check if the air filter is dirty refer to page 25 for cleaning instructions Check that there is no obstacle in front of the outdoor unit When heating the required room temperature is never reached and the air conditioner frequently stops...

Page 26: ... finish insert air filters by fixing them to each tab of the grille 5 To close the front grille fix it to hooks and push down the lower right and left tabs of the grille 6 Clean the front grille with a damp cloth and mild detergent do NOT use benzene solvents or other chemicals Note If you have not used the air conditioner for a long time select the Fan mode for 3 to 4 hours to dry the inside of t...

Page 27: ... the lower right and left tabs of the grille 2 Pull out the deodorizing and Bio filter 3 Wash the filters with clean water then dry them in the shade 4 Insert the filters in their place Note You can change the position of filters with each other 5 Close the front grille Deodorizing Filter Bio Filter Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 W...

Page 28: ...Memo Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 Web www amgair com Email info amgair com ...

Page 29: ...0 7267 www samsung com latin EL SALVADOR 800 6225 www samsung com latin GUATEMALA 1 800 299 0013 www samsung com latin JAMAICA 1 800 234 7267 www samsung com latin PANAMA 800 7267 www samsung com latin PUERTO RICO 1 800 682 3180 www samsung com latin REP DOMINICA 1 800 751 2676 www samsung com latin TRINIDAD TOBAGO 1 800 SAMSUNG 726 7864 www samsung com latin VENEZUELA 0 800 100 5303 www samsung c...

Reviews: