3-2
3-2 Indoor Display Error and Check Method
No
LED Display
Explanation
Explanation
1
IPM Over Current(O.C)
2
Compressor Starting Error
3
Compressor Lock Error
4
DC-Link voltage under/over Error
5
Outdoor temperature sensor Error
6
Discharge over temperature
7
Discharge temperature sensor Error
8
Current sensor Error
9
Compressor Vlimit Error
10
Coil temperature sensor Error
11
1min. Time out Communication
12
Fan Error
13
OTP Error
14
Compressor Rotation Error
15
/
(Low/High)
Operation condition secession
16
DC-Link valtage sensor Error
17
I_Trip error / PFC Over current
18
Gas Leak Error
19
AC Line Zero Cross Signal out
20
Capacity Miss-match
21
Room sensor Error
Open/Short
22
In-coil sensor Error
Open/Short
23
FAN Error
Indoor Fan Motor Abnormal Operation
Holding for 15 sec. at less than 450rpm
24
1min. Time out Communication
25
MPI Error
26
All Lamps Blink
EEPROM Error
27
All Lamps Blink
Option Error
Option Not Set up, Option Data Error
Samsung Electronics
Summary of Contents for AQV09VBA Series
Page 28: ...MEMO Samsung Electronics 4 11 ...
Page 29: ...Samsung Electronics 5 1 5 Exploded Views and Parts List 5 1 Indoor Unit ...
Page 31: ...Samsung Electronics 5 2 Outdoor Unit 5 3 ...
Page 34: ...MEMO Samsung Electronics 5 6 ...
Page 35: ...Samsung Electronics 5 7 5 4 Ass y Control Out AQV09VBCX DB93 05534E AQV12VBCX DB93 05534F ...
Page 50: ...7 3 Samsung Electronics MEMO ...
Page 88: ...Samsung Electronics OUTDOOR FAN B D IGBT Block Diagram 13 4 DIODE IPM SMPS DC_LINK CAP ...