2-2
Samsung Electronics
2-2 Product Specifications
Model
Item
AQV09NSA/AQV09FC
AQV12NSA/AQV12FC
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
Type
Wall-mounted
Wall-mounted
Performance
Capacity
Cooling
kW
(Low / Std / Max)
0.99 / 2.50 / 3.20
0.99 / 3.30 / 3.80
Heating
1.20 / 3.30 / 4.20
1.40 / 4.00 / 4.70
Running Frequency
Cooling
Hz
(Low / Std / Max)
20 / 52 / 70
25 / 69 / 79
Heating
25 / 64 / 75
30 / 76 / 88
Dehumidifying
ℓ/h
1.3
1.6
Air Volume
Cooling
㎥
/min
(H/M/L)
7.2/5.8/4.0
30
8.5/6.9/5.2
30
Heating
7.8/6.6/4.6
29
9.2/7.5/6.0
29
Noise
Cooling
dB
(H/L)
43 / 25
53
43 / 25
53
Heating
43 / 25
53
43 / 25
53
Energy Efficiency Ratio
Cooling
W/W
(Std)
3.40
3.21
Heating
3.63
3.61
Power
ph-V-Hz
1-220/240-50
1-220/240-50
Power
Power Consumtion
Cooling
W
(Low / Std / Max)
270 / 735 / 980
320 / 1028 / 1210
Heating
300 / 910 / 1100
350 / 1108 / 1400
Operating Current
Cooling
A
(Low / Std / Max)
1.6 / 3.5 / 4.5
1.9 / 4.9 / 5.5
Heating
1.7 / 4.4 / 5.2
2.2 / 5.2 / 6.2
Power Factor
Cooling
%
(Low / Std / Max)
70 / 85 / 90
70 / 90 / 90
Heating
70 / 85 / 90
70 / 90 / 90
Power Cord
Length
m
2
2
Number of Core Wire
3
3
Capacity
A
10
10
Size
Outer Dimension
W x H x D
mm
825x285x189
720x548x265
825x285x189
720x548x265
Weight (Net)
kg
7.8
31.5
9.4
31.5
Refrigerant Pipe
Liquid
mm x L(m)
Φ6.35 x 5
Φ6.35 x 5
Gas
mm x L(m)
Φ9.52 x 5
Φ9.52 x 5
Drain Hose
D x L(mm)
Φ18 x 550
Φ18 x 550
Compressor
Type
Rotary, G4C090LUDER
Rotary, G4C090LUDER
Motor
Type
Hermetic
Hermetic
Rated Output
853W
853W
Oil Type
FREOLα68ES-T
FREOLα68ES-T
Blower
Type
Cross-flow
Propeller
Cross-flow
Propeller
Motor
Type
Resin / Steel
Resin / Steel
Resin / Steel
Resin / Steel
Rated Output
W
27
50
27
50
Heat Exchanger
2 Row 10 Step
1 Row 20 Step
2 Row 10 Step
1 Row 20 Step
Refrigerant Control Unit
Check Valve, Capillary
Check Valve, Capillary
Freezer Oil Capacity
cc
320
320
Refrigerant to Change (R410A)
g
800
850
Protection Device (OLP)
None
None
Cooling Test Condition
Indoor Unit : DB27°C WB 19°C
Outdoor Unit : DB35°C WB 24°C
Heating Test Condition
Indoor Unit : DB20°C WB 15°C
Outdoor Unit : DB7°C WB 6°C
Operation conditon range
cooling
indoor
16°C ~ 32°C
16°C ~ 32°C
Outdoor
-10°C ~ 43°C
-10°C ~ 43°C
heating
indoor
27°C or less
27°Cor less
Outdoor
-15°C ~ 24°C
-15°C ~ 24°C
Summary of Contents for AQV09FC
Page 26: ...MEMO Samsung Electronics 4 9 ...
Page 27: ...Samsung Electronics 5 1 5 Exploded Views and Parts List 5 1 Indoor Unit ...
Page 29: ...Samsung Electronics 5 2 Outdoor Unit 5 3 ...
Page 32: ...MEMO Samsung Electronics 5 6 ...
Page 33: ...Samsung Electronics 5 7 5 4 Ass y Control Out AQV09NSAX DB93 05534C AQV12NSAX DB93 05534D ...
Page 80: ...Samsung Electronics Block Diagram 13 4 OUTDOOR FAN B D IGBT DIODE IPM SMPS DC_LINK CAP ...