Temperature and Humidity Ranges

    

If the outdoor temperature is as low as 0°C, the heating capacity drops up to 70~80% depending on  
the operating condition.  
If you use the air conditioner in temperatures over 32°C (indoor temperature), the cooling capacity may drop.

If you check the following tables, you can use your air conditioner more efficiently.

If the air conditioner is used at...

Then...

Heating capacity

The air conditioner may stop operating for the reason of protection.

Low temperatures

Water may leak and some malfunction may occur if the heat exchanger freezes. 

Protection mechanism

Water may condense and drip from the surface of the indoor unit if you don’t use  

the air conditioner for an extended period of time.

Operating Recommendations

Operation

Outdoor Temperature

Indoor Temperature

Indoor Humidity

AQV09F

/AQV12F

AQV18F

/AQV24F

Heating

-10°C to 24°C approx.

-15°C to 24°C approx.

27°C or less

-

Cooling

10°C to 43°C approx.

-10°C to 43°C approx.

16°C to 32°C approx.

80% or less

Dehumidifying

10°C to 43°C approx.

-10°C to 43°C approx.

16°C to 32°C approx.

-

Here are a few recommendations that you should follow when using your air conditioner.

Topic

Recommendation

Heating performances The heat pump function of the air conditioner absorbs heat from outside air and brings it  

indoors. As the temperature of the outside air drops, the heating performance of air  

conditioner will decrease. If you find that the room is not warm enough, using an additional 

heating appliance is recommended.

Warm air circulation

The air conditioner circulates warm air to heat your room. It will take some time to warm the

air in your room entirely after the air conditioner turns on. Therefore, turn the air conditioner on 

in advance.

Frost

When outdoor temperature is low but humidity is high, frost may form on the outdoor unit at

Heat mode.



The heating operation stops.



The defrost mode will be triggered automatically for 3 to 14 minutes.

No intervention is required ; after about 7 minutes, the air conditioner operates again normally.

High indoor and  

outdoor temperatures

If both indoor and outdoor temperatures are high and the air conditioner is running at HEAT 

mode, the outdoor unit’s fan and compressor may stop at times. This is normal;simply wait until 

the air conditioner switches on again.

Power failure

If a power failure occurs while the air conditioner is operating, the unit will be switched off. 

When the power returns, the air conditioner starts up again automatically.

Protection mechanism When the air conditioner is started immediately after being plugged in or stopped, the normal 

operation starts up after 3 minutes for the reason of protection.

Cooling operation

The indoor unit may not get the selected fan speed such as Medium and Low under cooling

operation at very low outdoor temperatures for the protection of the indoor unit from ice

or frost. 

During Low fan speed operation, cooling performance will be reduced. If the room does not be 

cooled down when using Low fan speed operation, please adjust the indoor unit’s fan speed.

Silence Mode

When you operate Silence Mode in cooling and heating, fan speed will decrease to make noise 

quieter. 

As a result, the performance of the unit may be reduced.

FORTE_Inv_IB_E.indd   26

2007-2-16   13:51:58

Summary of Contents for AQV09F** Series

Page 1: ...nmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial waste for disposal PREPARATION Safety Precautions 3 Name of Each Part 8 Remote Control Buttons and Display 10 Inserting the Remote Control Batteries 11 Getting Started 12 OPERATION Selecting Auto Mode 13 Selecting C...

Page 2: ...dusetheairconditionerproperly Keepthisuser smanualtogetherwiththeinstallationmanualinahandyplacesothatyoucanfinditwhenever youneedtoseeitafterreadingthismanualthoroughly WARNING This indicates the possibility of serious injury or death CAUTION This indicates the possibility of serious injury or damage to environments when operated incorrectly Do not install the unit in a place where it is exposed ...

Page 3: ...If applicable When using a wireless remote control the distance should not be more than 7 meters from the air conditioner If applicable Do not place any materials so that children cannot step on it Do not connect the electric heater to the air conditioner or repair it with your discretion The manufacturer declines any liability for damage resulting from modifications or errors in the electrical or...

Page 4: ...ry Releasing refrigerant into the atmosphere also damages the environments Please recycle or dispose of the packaging material for this product in an environmentally responsible manner DISPOSING THE UNIT WARNING Install the air conditioner avoiding direct sunlight or heater especially water Install the outdoor unit so as to let the discharged air out properly Avoid a place that may disturb your ne...

Page 5: ...burning smell or smoke blow REGARDING POWER SOURCE Do not open the front grille during operation Avoid cold and hot air reaching to person pet or a plant directly for a long time Avoid the water from getting into the air conditioner DURING OPERATION Do not use the air conditioner for a long time in a closed room or in a place where there s a baby or an old person Do not step on the air conditioner...

Page 6: ...he input power current is measured according to the ISO standard OTHERS Be sure that the air filter not to be exposed to direct sunlight Do not clean the air conditioner by spraying water directly or with benzene thinner or alcohol The surface of the heat exchanger is sharp so be careful of it when cleaning Turn off the air conditioner and if the fan stops to operate clean the air conditioner Clea...

Page 7: ...ape can be changed according to the model Indoor Unit Air filter under the grille Air flow blades outlet Air Inlet Temperature sensor Power On Off button Operation indicator GREEN Timer indicator GREEN Turbo indicator RED Power On Off button ...

Page 8: ...E 9 ENGLISH Air Outlet Air Inlet Rear Connection Valve Air Outlet Air Inlet Rear Connection Valve AQV09F Series AQV12F Series AQV18F Series AQV24F Series Outdoor Unit Outdoor Unit ...

Page 9: ...Timer button On Off Timer Set Cancel button Fan speed adjustment button Silence mode button Temperature adjustment buttons Temperature setting Good Sleep mode indicator Turbo function indicator Fan speed Silence indicator Air flow direction On Timer indicator Off Timer indicator Battery discharge indicator Good Sleep button Operating mode indicator AUTO COOL DRY FAN HEAT ...

Page 10: ...Note Use two AAA LR03 1 5V batteries Do not use old and new batteries or different kinds of batteries together Insert two batteries correctly as indicated by the and symbols 1 Remove the battery cover in the rear of the remote control by pushing it with your thumb 2 Insert two batteries respecting the polarities as indicated by the and symbols 3 Close the cover by sliding it back in place ...

Page 11: ...onditioner s features please read this manual carefully before using You have already seen the basic description of the unit on pages from 8 to 10 Starting with the next page you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use three different symbols PRESS PUSH HOLD DOWN ...

Page 12: ...to mode Auto mode cools or heats the room depending on the set temperature The air conditioner changes from Cool or Heat mode automatically depending on the current temperature Note You can change modes at any time 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 16 C and 30 C Result Each time you press the button The temp...

Page 13: ...erature until the required temperature is displayed You can set the temperature between 16 C and 30 C Result Each time you press the button The temperature adjusts by 1 C The indoor unit beeps If the room temperature is higher than the selected temperature the air conditioner starts cooling If the room temperature reaches the set temperature the air conditioner stops cooling but the fan continues ...

Page 14: ...16 C and 30 C Result Each time you press the button The temperature adjusts by 1 C The indoor unit beeps If the room temperature reaches 5 C higher than the set temperature the air conditioner stops heating but the fan continues to operate If the room temperature reaches 3 C lower than the set temperature the air conditioner starts heating again 4 Press the button to select the fan speed until the...

Page 15: ...trol until is displayed Result The indoor unit beeps each time you press the button The air conditioner runs in the Dry mode Note You can change modes at any time 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 16 C and 30 C Result Each time you press the button The temperature adjusts by 1 C The indoor unit beeps The air...

Page 16: ...e mode you selected last The indoor unit beeps 2 Press the button on the remote control until is displayed Result The indoor unit beeps each time you press the button The air conditioner runs in Fan mode The temperature is set automatically Note You can change modes at any time 3 Press the button to select the fan speed until the required setting is displayed Low Medium High Result Each time you p...

Page 17: ... heat mode 3 Press the button The remote control display shows you that this mode automatically stops after 8 hour operation In the case of adjusting time Press the button to adjust desired operation time from 30 minutes to 12 hours Good Sleep mode will automatically stop after the set time Press the button Result In the case of adjusting the extra time for Good Sleep mode you should press the but...

Page 18: ...ing wavy temperature control and insensible air stream Wake Up Stage This stage supports comfortable intermittent air to the room to raise human body temperature for refreshing wake up The recommended temperature is set between 25 C and 27 C and 26 C is the most ideal temperature for comfortable sleep Airflow blades and fan speed are controlled automatically as the above 3 stages in Good Sleep mod...

Page 19: ... last The indoor unit beeps 2 Press the button Result The temperature and fan settings are adjusted automatically The air conditioner cools or heats the room as quickly as possible After 30 minutes the air conditioner is reset automatically to the previous setting You can select theTurbo function in Auto Cool and Heat mode If you select this function in Dry or Fan mode the mode changes to Auto mod...

Page 20: ...e the blade up and down automatically during operation 3 Press the button again to stop the blade moving up and down Note If you turn the air conditioner Then the blade Off is closed completely On set to the default position Adjusting the Airflow Direction Horizontally You can adjust airflow direction horizontally manually The inner blades with small fins move the air in the desired direction 1 Adj...

Page 21: ...disappear after 10 seconds The air conditioner turns on automatically at the appointed time and the On Timer setting disappears 3 Press the button until the desired mode is displayed at the top of the remote control to select the mode in advance Result The air conditioner operates in the selected mode when it is turned on To Cancel the On Timer If you no longer wish to use the On Timer that you ha...

Page 22: ...If you would like to turn on the air conditioner and then to turn off it automatically at the appointed time by using On OffTimer during operation you should set the OnTimer longer than the OffTimer Caution Make sure that the air conditioner will not continue to run after OnTimer setting is confirmed Note You can check or change the mode and or the temperature by pressing the button or the button ...

Page 23: ...omes on The indoor unit beeps The air conditioner starts up in the most suitable mode for the room temperature The mode may change from cooling into heating from heating into cooling depending on the current temperature during operation RoomTemperature Operating Mode Less than 24 C Heat 24 C or above Cool 2 To switch the air conditioner off press the ON OFF switch again Note Even if the air condit...

Page 24: ...ower right and left tabs of the grille 6 Clean the front grille with a damp cloth and mild detergent do NOT use benzene solvents or other chemicals Note If you have not used the air conditioner for a long period of time set the fan going for three to four hours to dry the inside of the air conditioner thoroughly Front grille Air filter Body groove Body Front grille Hook Body To remove minute dust ...

Page 25: ...irculation The air conditioner circulates warm air to heat your room It will take some time to warm the air in your room entirely after the air conditioner turns on Therefore turn the air conditioner on in advance Frost When outdoor temperature is low but humidity is high frost may form on the outdoor unit at Heat mode The heating operation stops The defrost mode will be triggered automatically fo...

Page 26: ...er under direct sunlight The window or door may be opened Check if you turn on the air conditioner just now It takes about 3 minutes to cool or heat the room Check if the drain pipe is too long The fan speed is not adjusted In Dry mode the fan speed is selected automatically The remote control does not operate Check if the battery is discharged Replace the battery Check if the remote control senso...

Page 27: ...w samsung lu NETHERLANDS 0900 20 200 88 0 10 min www samsung com nl NORWAY 815 56 480 www samsung com no POLAND 0 801 801 881 www samsung com pl PORTUGAL 80 8 200 128 www samsung com pt SLOVAKIA 0800 SAMSUNG 726786 www samsung com sk SPAIN 902 10 11 30 www samsung com es SWEDEN 0771 400 200 www samsung com se U K 0870 SAMSUNG 7267864 www samsung com uk REPUBLIC OF IRELAND 0818 717 100 www samsung ...

Page 28: ...NGLISH Split type Air Conditioner Cooling and Heating DB98 27529A 1 S E F I P ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA D G USER SMANUAL AQV09F Series AQV12F Series AQV18F Series AQV24F Series ...

Reviews: