
Samsung Electronics
4-7
4-3-4 EEPROM Error or Option Error
1. Checklist :
1) If all lamps of Indoor unit are blinking or E16 is displayed,plug out,plug in power plug again and press ON/OFF key to retry.
) If the unit is not working properly or all lamps are continuously blinking or E16 is displayed after resetting the option code,
see if the correct option code is set up for its model.
3) Nevertheless, if all lamps are blinking or E16 is displayed, exchange the main PBA.
4-3-5 MPI Feedback Error
When E186 is displayed
1. Checklist :
1) Is the mpi connector properly connected with the connector(CN81)?
. Troubleshooting procedure
Poor MPI Replace
Yes
Normal
No
Check as in the procedure "No power parts"
No
Does the Operation Lamp blink?
After unplugging out the power cord should be
reconnected within 5 seconds
Press the mpi button
Yes
E186 is displayed?
Measure the voltage of #4 of the
CN81 connector and # of the CN44
connector.
Below 11V?
Poor Ass'y PCB Replace
Yes
No
No
Yes
Summary of Contents for AQ07**SER Series
Page 23: ...4 2 Samsung Electronics 4 1 Setting Option Setup Method continue ...
Page 37: ...Samsung Electronics 6 1 6 PCB Diagram and Parts List 6 1 Block Diagram 6 1 1 Ass y Control In ...
Page 38: ...6 2 Samsung Electronics ...
Page 44: ...Samsung Electronics 7 Wiring Diagram AQ07 7 1 ...
Page 45: ...7 2 Samsung Electronics AQ07 ...
Page 46: ...8 Schematic Diagram 8 1 PCB Circuit Description 8 1 1 Indoor Unit Sam sung Confidential 8 1 ...